Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-121810
Description: This issue affects NGINX Plus and NGINX Open Source configurations that use HTTP/3. A remote, unauthenticated attacker can cause a use-after-free condition in the NGINX worker process, leading to a restart. Exploitation also depends on conditions beyond the attacker’s control. Additionally, attackers can execute code on systems with Address Space Layout Randomization (ASLR) disabled or when the attacker can bypass ASLR. Impact: This vulnerability may allow remote attackers to cause a denial-of-service (DoS) on the NGINX system or to possibly trigger a code execution. There is no control plane exposure; this is a data plane issue only. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
This record: live connection— last retrieved: 20 November 2026 at 19:46.
Vendor
Published
18 November 2026
Last modified
20 November 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Description: This issue affects NGINX Plus and NGINX Open Source configurations that use HTTP/3. A remote, unauthenticated attacker can cause a use-after-free condition in the NGINX worker process, leading to a restart. Exploitation also depends on conditions beyond the attacker’s control. Additionally, attackers can execute code on systems with Address Space Layout Randomization (ASLR) disabled or when the attacker can bypass ASLR. Impact: This vulnerability may allow remote attackers to cause a denial-of-service (DoS) on the NGINX system or to possibly trigger a code execution. There is no control plane exposure; this is a data plane issue only. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
1.7%
Percentile
77e
Source: FIRST.org, updated on 20 November 2026.
The following measure can be configured using a Web Application Firewall (WAF) or a reverse proxy: Disable HTTP/3/QUIC on affected services.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 8.1, EPSS 1.7%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 20 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.