Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-12562
The RCU II+ and Multiload II+ are vulnerable to an unauthenticated service that exposes a debug interface granting full root-level access to the embedded system. This vulnerability stems from a network-accessible port running a Target Communications Framework (TCF) service that does not require any authentication, allowing an attacker to directly interact with the Linux environment that powers the device. Once connected, an attacker can freely view and modify the filesystem, manipulate running processes, and control network interfaces, enabling deep alteration of system behavior.
This record: live connection— last retrieved: 24 September 2026 at 05:13.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
The RCU II+ and Multiload II+ are vulnerable to an unauthenticated service that exposes a debug interface granting full root-level access to the embedded system. This vulnerability stems from a network-accessible port running a Target Communications Framework (TCF) service that does not require any authentication, allowing an attacker to directly interact with the Linux environment that powers the device. Once connected, an attacker can freely view and modify the filesystem, manipulate running processes, and control network interfaces, enabling deep alteration of system behavior.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.3%
Percentile
21e
Source: FIRST.org, updated on 23 September 2026.
Toptech Systems provides two methods for remediating affected RCU II+ and Multiload II+ units: First, move the device to a closed or segmented network without untrusted access.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 8.8, EPSS 0.3%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping