Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-13599
Missing authentication for critical function vulnerability in ABB Ability Edgenius. This issue affects Ability Edgenius: through 3.2.3.0.
This record: live connection— last retrieved: 7 November 2026 at 14:22.
Vendor
Published
22 October 2026
Last modified
23 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Missing authentication for critical function vulnerability in ABB Ability Edgenius. This issue affects Ability Edgenius: through 3.2.3.0.
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.1%
Percentile
3e
Source: FIRST.org, updated on 6 November 2026.
Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove exposure with well-known impact on functionality. For brownfield customers, ABB provides a Kubernetes network policy that restricts access to Edge Authentication Database (AuthDB) to the authorized services required for normal operation of an already deployed and configured system. For implementation details, refer to Technical Description-ABB Ability Edgenius Missing Authentication in Edgenius AuthDB.docx (7PAA025722) listed in the reference section, distributed separately.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.8, EPSS 0.1%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "ABB" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.