CVE-2026-23287
In the Linux kernel, the following vulnerability has been resolved: irqchip/sifive-plic: Fix frozen interrupt due to affinity setting PLIC ignores interrupt completion message for disabled interrupt, explained by the specification: The PLIC signals it has completed executing an interrupt handler by writing the interrupt ID it received from the claim to the claim/complete register. The PLIC does not check whether the completion ID is the same as the last claim ID for that target. If the completion ID does not match an interrupt source that is currently enabled for the target, the completion is silently ignored. This caused problems in the past, because an interrupt can be disabled while still being handled and plic_irq_eoi() had no effect. That was fixed by checking if the interrupt is disabled, and if so enable it, before sending the completion message. That check is done with irqd_irq_disabled(). However, that is not sufficient because the enable bit for the handling hart can be zero despite irqd_irq_disabled(d) being false. This can happen when affinity setting is changed while a hart is still handling the interrupt. This problem is easily reproducible by dumping a large file to uart (which generates lots of interrupts) and at the same time keep changing the uart interrupt's affinity setting. The uart port becomes frozen almost instantaneously. Fix this by checking PLIC's enable bit instead of irqd_irq_disabled().
This record: live connection— last retrieved: 24 September 2026 at 05:13.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: irqchip/sifive-plic: Fix frozen interrupt due to affinity setting PLIC ignores interrupt completion message for disabled interrupt, explained by the specification: The PLIC signals it has completed executing an interrupt handler by writing the interrupt ID it received from the claim to the claim/complete register. The PLIC does not check whether the completion ID is the same as the last claim ID for that target. If the completion ID does not match an interrupt source that is currently enabled for the target, the completion is silently ignored. This caused problems in the past, because an interrupt can be disabled while still being handled and plic_irq_eoi() had no effect. That was fixed by checking if the interrupt is disabled, and if so enable it, before sending the completion message. That check is done with irqd_irq_disabled(). However, that is not sufficient because the enable bit for the handling hart can be zero despite irqd_irq_disabled(d) being false. This can happen when affinity setting is changed while a hart is still handling the interrupt. This problem is easily reproducible by dumping a large file to uart (which generates lots of interrupts) and at the same time keep changing the uart interrupt's affinity setting. The uart port becomes frozen almost instantaneously. Fix this by checking PLIC's enable bit instead of irqd_irq_disabled().
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.1%
Percentile
2e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.5, EPSS 0.1%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.