Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-2401
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
This record: live connection— last retrieved: 7 November 2026 at 18:56.
Vendor
Published
14 April 2026
Last modified
26 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N
Attack vector
LOCAL
Privileges required
LOW
User interaction
REQUIRED
Confidentiality
High
Integrity
None
Availability
None
Probability of exploitation within 30 days
0.1%
Percentile
1e
Source: FIRST.org, updated on 6 November 2026.
Version v1.5 of PowerChute™ Serial Shutdown includes a fix for this vulnerability and is available for download here: • Windows: https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Specific instructions and hardening guidelines for these mitigations can be found in the [Security Handbook](https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN).
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.0, EPSS 0.1%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Schneider Electric" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.