Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-31555
In the Linux kernel, the following vulnerability has been resolved: futex: Clear stale exiting pointer in futex_lock_pi() retry path Fuzzying/stressing futexes triggered: WARNING: kernel/futex/core.c:825 at wait_for_owner_exiting+0x7a/0x80, CPU#11: futex_lock_pi_s/524 When futex_lock_pi_atomic() sees the owner is exiting, it returns -EBUSY and stores a refcounted task pointer in 'exiting'. After wait_for_owner_exiting() consumes that reference, the local pointer is never reset to nil. Upon a retry, if futex_lock_pi_atomic() returns a different error, the bogus pointer is passed to wait_for_owner_exiting(). CPU0 CPU1 CPU2 futex_lock_pi(uaddr) // acquires the PI futex exit() futex_cleanup_begin() futex_state = EXITING; futex_lock_pi(uaddr) futex_lock_pi_atomic() attach_to_pi_owner() // observes EXITING *exiting = owner; // takes ref return -EBUSY wait_for_owner_exiting(-EBUSY, owner) put_task_struct(); // drops ref // exiting still points to owner goto retry; futex_lock_pi_atomic() lock_pi_update_atomic() cmpxchg(uaddr) *uaddr ^= WAITERS // whatever // value changed return -EAGAIN; wait_for_owner_exiting(-EAGAIN, exiting) // stale WARN_ON_ONCE(exiting) Fix this by resetting upon retry, essentially aligning it with requeue_pi.
This record: live connection— last retrieved: 24 September 2026 at 05:14.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: futex: Clear stale exiting pointer in futex_lock_pi() retry path Fuzzying/stressing futexes triggered: WARNING: kernel/futex/core.c:825 at wait_for_owner_exiting+0x7a/0x80, CPU#11: futex_lock_pi_s/524 When futex_lock_pi_atomic() sees the owner is exiting, it returns -EBUSY and stores a refcounted task pointer in 'exiting'. After wait_for_owner_exiting() consumes that reference, the local pointer is never reset to nil. Upon a retry, if futex_lock_pi_atomic() returns a different error, the bogus pointer is passed to wait_for_owner_exiting(). CPU0 CPU1 CPU2 futex_lock_pi(uaddr) // acquires the PI futex exit() futex_cleanup_begin() futex_state = EXITING; futex_lock_pi(uaddr) futex_lock_pi_atomic() attach_to_pi_owner() // observes EXITING *exiting = owner; // takes ref return -EBUSY wait_for_owner_exiting(-EBUSY, owner) put_task_struct(); // drops ref // exiting still points to owner goto retry; futex_lock_pi_atomic() lock_pi_update_atomic() cmpxchg(uaddr) *uaddr ^= WAITERS // whatever // value changed return -EAGAIN; wait_for_owner_exiting(-EAGAIN, exiting) // stale WARN_ON_ONCE(exiting) Fix this by resetting upon retry, essentially aligning it with requeue_pi.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.1%
Percentile
3e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.5, EPSS 0.1%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.