Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-3587
An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device.
This record: live connection— last retrieved: 7 November 2026 at 22:05.
Vendor
Published
23 March 2026
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.7%
Percentile
53e
Source: FIRST.org, updated on 7 November 2026.
Please update your devices to the specified fixed firmware version. | Product | Fixed Version | |-------------------------------------------|---------------| | Lean Managed Switch 852-1812 | V1.2.1.S1 | | Lean Managed Switch 852-1813 | V1.2.1.S1 | | Lean Managed Switch 852-1813/000-001| V1.2.3.S1 | | Lean Managed Switch 852-1816 | V1.2.1.S1 | | Industrial Managed Switch 852-303 | V1.2.8.S1 | | Industrial Managed Switch 852-1305 | V1.2.0.S1 | | Industrial Managed Switch 852-1305/000-001| V1.2.0.S1 | | Industrial Managed Switch 852-1505/000-001| V1.2.0.S1 | | Industrial Managed Switch 852-1505 | V1.1.9.S1 | | Industrial Managed Switch 852-602 | V1.0.6.S1 | | Industrial Managed Switch 852-603 | V1.0.6.S1 | | Industrial Managed Switch 852-1605 | V1.2.5.S1 | | Lean Managed Switch 852-1812/010-000| V1.2.1.S1 | | Lean Managed Switch 852-1813/010-000| V1.2.1.S1 | | Lean Managed Switch 852-1813/010-001| V1.2.1.S1 | | Lean Managed Switch 852-1816/010-000| V1.2.1.S1 |
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 10.0, EPSS 0.7%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "WAGO" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.