Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-43494
In the Linux kernel, the following vulnerability has been resolved: net/rds: reset op_nents when zerocopy page pin fails When iov_iter_get_pages2() fails in rds_message_zcopy_from_user(), the pinned pages are released with put_page(), and rm->data.op_mmp_znotifier is cleared. But we fail to properly clear rm->data.op_nents. Later when rds_message_purge() is called from rds_sendmsg() the cleanup loop iterates over the incorrectly non zero number of op_nents and frees them again. Fix this by properly resetting op_nents when it should be in rds_message_zcopy_from_user().
This record: live connection— last retrieved: 24 September 2026 at 05:14.
Published
21 May 2026
Last modified
23 July 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: net/rds: reset op_nents when zerocopy page pin fails When iov_iter_get_pages2() fails in rds_message_zcopy_from_user(), the pinned pages are released with put_page(), and rm->data.op_mmp_znotifier is cleared. But we fail to properly clear rm->data.op_nents. Later when rds_message_purge() is called from rds_sendmsg() the cleanup loop iterates over the incorrectly non zero number of op_nents and frees them again. Fix this by properly resetting op_nents when it should be in rds_message_zcopy_from_user().
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.3%
Percentile
23e
Source: FIRST.org, updated on 23 September 2026.
For affected products, software updates should be installed upon availability. Product Patch version - APROL : APROL-AutoYaST-DVD- V4.4-010.10.260602 Until remediated software versions are available, customers are required to conduct a risk assessment of their affected systems and to implement the mitigation measures and workarounds specified in this advisory.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.8, EPSS 0.3%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "B&R Industrial Automation GmbH" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.