CVE-2026-44094
An unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user "user-app". Charging could be interrupted.
This record: live connection— last retrieved: 7 November 2026 at 01:04.
Vendor
Published
30 July 2026
Last modified
30 July 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
An unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user "user-app". Charging could be interrupted.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
Limited
Integrity
Limited
Availability
High
Probability of exploitation within 30 days
0.5%
Percentile
39e
Source: FIRST.org, updated on 6 November 2026.
Phoenix Contact strongly recommends to upgrade to firmware version 1.9.1 which fixes these vulnerabilities.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 8.6, EPSS 0.5%, industrial relevance 60/100; raised due to relevance to internet exposure.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Phoenix Contact" is a known supplier of equipment for the energy sector. Description mentions industrial protocol: ssh.
This product uses protocols that are relevant to internet exposure analysis. An internet-reachable service is not automatically vulnerable.
Recommended defensive measures
Industrial relevance score
Automatically classified as industrially relevant based on CISA/NVD signals (see reasons).
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping