Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-59387
The Nginx routing configuration for Cloud Controller blocks unauthenticated access to /internal/v4/ and /internal/v5/ endpoints but omits an equivalent deny rule for /internal/v3/. As a result, the staging callback endpoints /internal/v3/staging/:guid/droplet_completed and /internal/v3/staging/:guid/build_completed are reachable from the public API listener without OAuth or mutual TLS. An attacker with a valid build or droplet GUID can submit a forged staging callback, transition a droplet to STAGED, and persist arbitrary process metadata and sidecar data with no associated package or actor. A SpaceAuditor can enumerate GUIDs without write permissions, making this an effective privilege escalation beyond the intended role boundary.
This record: live connection— last retrieved: 7 November 2026 at 14:22.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
The Nginx routing configuration for Cloud Controller blocks unauthenticated access to /internal/v4/ and /internal/v5/ endpoints but omits an equivalent deny rule for /internal/v3/. As a result, the staging callback endpoints /internal/v3/staging/:guid/droplet_completed and /internal/v3/staging/:guid/build_completed are reachable from the public API listener without OAuth or mutual TLS. An attacker with a valid build or droplet GUID can submit a forged staging callback, transition a droplet to STAGED, and persist arbitrary process metadata and sidecar data with no associated package or actor. A SpaceAuditor can enumerate GUIDs without write permissions, making this an effective privilege escalation beyond the intended role boundary.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
14e
Source: FIRST.org, updated on 6 November 2026.
No official patch information available at the time of retrieval; consult the official source.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 8.8, EPSS 0.2%, industrial relevance 20/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.