CVE-2026-65311
The HTTP server component of ANDRITZ HIPASE-250 (formerly 250 SCALA) in affected versions exposes an undocumented endpoint that changes the server's logging level and target without requiring authentication. A remote, unauthenticated attacker with network access to the service may suppress audit logging, potentially concealing other activity on the system.
This record: live connection— last retrieved: 24 September 2026 at 05:13.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
The HTTP server component of ANDRITZ HIPASE-250 (formerly 250 SCALA) in affected versions exposes an undocumented endpoint that changes the server's logging level and target without requiring authentication. A remote, unauthenticated attacker with network access to the service may suppress audit logging, potentially concealing other activity on the system.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
None
Integrity
Limited
Availability
None
Probability of exploitation within 30 days
0.3%
Percentile
19e
Source: FIRST.org, updated on 23 September 2026.
ANDRITZ has addressed these issues in version V8.00.00 (released 2024-12) and in version V8.15.00 (released 2026-07) and encourages users to keep their systems updated to the latest version (currently HIPASE-250 Version V8.15.00). For more information, users can contact ANDRITZ at the following website: https://www.andritz.com/group-en/contact
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.3, EPSS 0.3%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.