Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-76287
In Splunk Enterprise versions below 10.4.4, a user that holds a role with the preview_data_management_pipeline capability or edit_data_management_pipeline_job capability could read or delete Data Management SPL2 preview jobs and results outside their ownership scope. The vulnerability is possible because the Data Management Representational State Transfer (REST) API verifies the required capability but does not verify that the requested preview job belongs to the requester. The affected Data Management REST API is available only when the Edge Processor feature is turned on. The Edge Processor feature is turned off by default. For more information see Set up a data management control plane (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/getting-started/set-up-a-data-management-control-plane) and Getting sample data for previewing data transformations (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/working-with-pipelines/getting-sample-data-for-previewing-data-transformations) in the Splunk documentation.
This record: live connection— last retrieved: 8 November 2026 at 09:19.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In Splunk Enterprise versions below 10.4.4, a user that holds a role with the preview_data_management_pipeline capability or edit_data_management_pipeline_job capability could read or delete Data Management SPL2 preview jobs and results outside their ownership scope. The vulnerability is possible because the Data Management Representational State Transfer (REST) API verifies the required capability but does not verify that the requested preview job belongs to the requester. The affected Data Management REST API is available only when the Edge Processor feature is turned on. The Edge Processor feature is turned off by default. For more information see Set up a data management control plane (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/getting-started/set-up-a-data-management-control-plane) and Getting sample data for previewing data transformations (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/working-with-pipelines/getting-sample-data-for-previewing-data-transformations) in the Splunk documentation.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Attack vector
NETWORK
Privileges required
LOW
User interaction
NONE
Confidentiality
Limited
Integrity
Limited
Availability
None
Probability of exploitation within 30 days
0.2%
Percentile
12e
Source: FIRST.org, updated on 7 November 2026.
No official patch information available at the time of retrieval; consult the official source.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.4, EPSS 0.2%, industrial relevance 25/100; raised due to relevance to internet exposure.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
This product uses protocols that are relevant to internet exposure analysis. An internet-reachable service is not automatically vulnerable.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 8 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.