Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-76293
In Splunk Enterprise versions below 10.4.3, 10.2.8, 10.0.11, and 9.4.16, a user that holds a role with the edit_manager_xml capability could execute arbitrary operating-system commands using the permissions of the user account running Splunk Enterprise by opening the affected configuration in the Splunk Web Manager page. The vulnerability is possible because Splunk Web evaluates user-controlled expressions from Manager XML without sufficiently restricting the expression syntax.
This record: live connection— last retrieved: 8 November 2026 at 08:48.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In Splunk Enterprise versions below 10.4.3, 10.2.8, 10.0.11, and 9.4.16, a user that holds a role with the edit_manager_xml capability could execute arbitrary operating-system commands using the permissions of the user account running Splunk Enterprise by opening the affected configuration in the Splunk Web Manager page. The vulnerability is possible because Splunk Web evaluates user-controlled expressions from Manager XML without sufficiently restricting the expression syntax.
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
HIGH
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.5%
Percentile
41e
Source: FIRST.org, updated on 7 November 2026.
No official patch information available at the time of retrieval; consult the official source.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.2, EPSS 0.5%, industrial relevance 20/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 8 November 2026.
IEC 62443 mapping