CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.
This record: live connection— last retrieved: 7 November 2026 at 16:54.
Vendor
Published
9 June 2026
Last modified
20 July 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Attack vector
NETWORK
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
None
Availability
None
Probability of exploitation within 30 days
0.2%
Percentile
14e
Source: FIRST.org, updated on 6 November 2026.
v9.1.2 of EcoStruxure™ IT Data Center Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/en/product-range/61851-ecostruxure-it-data- center-expert/#software-and-firmware
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 6.5, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Schneider Electric" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.