Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-84854
In the WibuKey driver for Windows below Version 6.72, insufficient validation of user input when calculating the size of a kernel buffer could cause small amounts of data to be written outside the intended kernel buffer. This can lead to a system crash. Under unfavorable circumstances, adjacent kernel memory may be modified.
This record: live connection— last retrieved: 7 November 2026 at 14:22.
Vendor
Published
6 October 2026
Last modified
15 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the WibuKey driver for Windows below Version 6.72, insufficient validation of user input when calculating the size of a kernel buffer could cause small amounts of data to be written outside the intended kernel buffer. This can lead to a system crash. Under unfavorable circumstances, adjacent kernel memory may be modified.
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.1%
Percentile
1e
Source: FIRST.org, updated on 6 November 2026.
Install WIBU Systems WibuKey Runtime for Windows 6.72 or later version manually to fix the issue: Download the package from <a href="https://www.wibu.com/support/user/user-software.html">User Software - Wibu-Systems</a> and follow the installation instructions from WIBU Systems.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.0, EPSS 0.1%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.