CVE-2026-89209
A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions < V4.2.4), Mendix SAML (Mendix 11 compatible) (All versions < V4.2.4), Mendix SAML (Mendix 9 compatible) (All versions < V3.6.29). Affected versions of the module do not properly protect against SAML assertion replay in IdP-initiated authentication flows. This could allow unauthenticated remote attackers to gain unauthorized access to the application by replaying a valid SAML response.
This record: live connection— last retrieved: 7 November 2026 at 13:21.
Vendor
Published
26 October 2026
Last modified
31 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions < V4.2.4), Mendix SAML (Mendix 11 compatible) (All versions < V4.2.4), Mendix SAML (Mendix 9 compatible) (All versions < V3.6.29). Affected versions of the module do not properly protect against SAML assertion replay in IdP-initiated authentication flows. This could allow unauthenticated remote attackers to gain unauthorized access to the application by replaying a valid SAML response.
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N
Attack vector
NETWORK
Privileges required
NONE
User interaction
REQUIRED
Confidentiality
High
Integrity
High
Availability
None
Probability of exploitation within 30 days
0.3%
Percentile
18e
Source: FIRST.org, updated on 6 November 2026.
Disable IdP-initiated SSO
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 6.8, EPSS 0.3%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping