CVE-2026-9108
A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution.
This record: live connection— last retrieved: 24 September 2026 at 05:10.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution.
CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
REQUIRED
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.1%
Percentile
3e
Source: FIRST.org, updated on 23 September 2026.
Rockwell Automation recommends users to upgrade to the following: Studio 5000 Logix Designer: V37.00, 36.01, 35.02, 34.04, 33.04, 32.05 (CVE-2026-9108)
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.5, EPSS 0.1%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Rockwell Automation" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping