Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-9593
A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory, potentially resulting in unauthorized access to connected devices and exposure, modification, or disruption of device data or operation.
This record: live connection— last retrieved: 7 November 2026 at 02:05.
Vendor
Published
3 August 2026
Last modified
24 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory, potentially resulting in unauthorized access to connected devices and exposure, modification, or disruption of device data or operation.
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
HIGH
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
6e
Source: FIRST.org, updated on 6 November 2026.
If an immediate update is not possible, Endress+Hauser recommends the following measures to reduce the risk of exploitation: * Restrict access to affected systems to authorized personnel only * Apply the principle of least privilege and limit administrative access to trusted users. * Protect application installation directories against unauthorized modification through appropriate operating system access controls. Following these recommendations reduces the risk of unauthorized activation.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 6.7, EPSS 0.2%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.