Loading vulnerabilities…
Loading vulnerabilities…
CVE-2020-7925
Incorrect validation of user input in the role name parser may lead to use of uninitialized memory allowing an unauthenticated attacker to use a specially crafted request to cause a denial of service. This issue affects MongoDB Server v4.4 versions prior to 4.4.0-rc12; MongoDB Server v4.2 versions prior to 4.2.9.
This record: live connection— last retrieved: 24 September 2026 at 05:11.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Incorrect validation of user input in the role name parser may lead to use of uninitialized memory allowing an unauthenticated attacker to use a specially crafted request to cause a denial of service. This issue affects MongoDB Server v4.4 versions prior to 4.4.0-rc12; MongoDB Server v4.2 versions prior to 4.2.9.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
1.7%
Percentile
76e
Source: FIRST.org, updated on 23 September 2026.
ABB recommends the following mitigation measures: - Replace bundled MongoDB with a supported version if IIoT services are required: - Where IIoT functionality is required, the bundled MongoDB instance can be replaced with a supported and patched version through manual configuration. - The following zenon online help section explains the process of installing and using your own MongoDB database: zenHelpViewer - Uninstall IIoT Services wherever it’s not required: - If IIoT Services are not required, they can be removed using the Control panel uninstaller. This eliminates the dependency on MongoDB without affecting other zenon components. Refer to section “General security recommendations” for further advise on how to keep your system secure.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.5, EPSS 1.7%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "ABB" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.