Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-35996
KUNBUS PiCtory version 2.11.1 and earlier are vulnerable when an authenticated remote attacker crafts a special filename that can be stored by API endpoints. That filename is later transmitted to the client in order to show a list of configuration files. Due to a missing escape or sanitization, the filename could be executed as HTML script tag resulting in a cross-site-scripting attack.
This record: live connection— last retrieved: 7 November 2026 at 04:07.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
KUNBUS PiCtory version 2.11.1 and earlier are vulnerable when an authenticated remote attacker crafts a special filename that can be stored by API endpoints. That filename is later transmitted to the client in order to show a list of configuration files. Due to a missing escape or sanitization, the filename could be executed as HTML script tag resulting in a cross-site-scripting attack.
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
LOW
User interaction
REQUIRED
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
19.3%
Percentile
97e
Source: FIRST.org, updated on 6 November 2026.
Update the PiCtory package to version 2.12 via the 'apt' package manager. Use 'sudo apt update && sudo apt upgrade -y' to pull and install all available updates for the IndustrialPI. To check the version of the pictory package, use 'dpkg -l | grep pictory'.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 9.0, EPSS 19.3%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.