3ADR011572
Automation Builder, Drive Application Builder, Virtual Drive, Virtual DrivePlus Impacted by multiple vulnerabilities in Wibu CodeMeter
Gepubliceerd
3 september 2026
Laatste update
3 september 2026
Getroffen sectoren
Risk evaluation
An update is available that resolves publicly reported vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could - allow arbitrary files to be deleted with system privileges (CVE-2026-81572), - read potentially sensitive configuration data and overwrite selected values in Server.ini (CVE-2026-81573), - crash CodeMeter and disclose sensitive information such as process memory and stack canaries (CVE-2026-81574), - crash CodeMeter (CVE-2026-81575), or - read potentially sensitive license information (CVE-2026-81576)
Mitigatiesamenvatting
For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts. For CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network server functionality at some point but no longer need it, disable it: - Open the Registry Editor and navigate to Computer\HKEY_LOCAL_MACHINE\SOFTWARE\ WIBUSYSTEMS\CodeMeter\Server\CurrentVersion\, then change the value of IsNetworkServerfrom 1 to 0. - Restart CodeMeter.
Revisiegeschiedenis (1)
Initiële publicatie — 3 september 2026