Advisory2026-02_VDE-2026-011

CODESYS Control V3 - Untrusted boot application

CODESYS — CODESYS Control RTE (SL)

CODESYS PSIRThoog

Gepubliceerd

24 maart 2026

Laatste update

18 juni 2026

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The CODESYS Control runtime system provides a user management mechanism with multiple privilege groups. While only the privileged Administrators and Developer groups are intended to load or debug applications on the controller, users in the restricted Service group are allowed to perform maintenance operations, including explicitly replacing the boot application. In addition to access control, the CODESYS Control runtime system includes an optional application signing feature. When enabled, the controller executes only applications that have been validly signed by authorized developers. However, the CmpApp component of the CODESYS Control runtime systems allows Service‑group users to install a new boot application without requiring any cryptographic validation, if the application signing is not enforced. As a result, users with Service‑level privileges can install arbitrary boot applications and gain control over the code executed on the controller. Note: The user group "Service" is a predefined group within the CODESYS Control runtime system. If additional user groups have been created or if the permissions of predefined groups have been modified, then the term "Service" should be understood as a synonym for all groups and their users with no or only limited access rights to the "PlcLogic" object, in conjunction with "Add/Remove" or "Modify" permissions for the boot application files.

Mitigatiesamenvatting

Without applying the update, the vulnerability can be mitigated by enforcing the use of signed applications through the following setting: [CmpApp] SECURITY.EnforceSignedCode=YES This can be configured either via the Device Security Settings dialog in the CODESYS Development System or directly in the configuration file of the CODESYS Control runtime system (CODESYSControl.cfg). When this option is enabled, the CODESYS Control runtime system loads only trusted and valid signed applications. Alternatively, all users belonging to the Service group can be removed, or the Service group can be deleted entirely. If none of the other mitigation options are feasible, the permissions of the Service group can be restricted by adjusting their access rights. For example, removing modify permissions for the Service group on relevant file system objects can prevent the upload of untrusted boot applications. However, such changes must be applied with caution, as they may lead to inconsistent permissions for this user group and result in unexpected operational limitations. Therefore, this approach should only be considered after a careful assessment of the specific situation.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 24 maart 2026

    Initial revision.

  2. Update A — 18 juni 2026

    Updated remediation category - fixed SL runtimes are now available.

Officiële bron: CODESYS PSIRT