SEVD-2025-042-02
Improper Input Validation Vulnerability in Uni-Telway Driver
Gepubliceerd
11 februari 2025
Laatste update
12 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Schneider Electric is aware of a vulnerability in its [Uni-Telway driver](https://www.se.com/us/en/product-range/573-unitelway/#overview) which is part of [EcoStruxure™ Control Expert](https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#overview), [EcoStruxure™ Process Expert](https://www.se.com/ww/en/product-range/65406-ecostruxure-process-expert), [EcoStruxure™ Process Expert for AVEVA System Platform](https://www.se.com/ww/en/product-range/55570689-ecostruxure-process-expert-for-aveva-system-platform/#overview) and [OPC Factory Server](https://www.se.com/ww/en/product-range/547-opc-factory-server/) products. Failure to apply the mitigations provided below may risk denial of service of engineering workstation, which could result in interruption of engineering operation.
Mitigatiesamenvatting
For customers requiring the use of Uni-Telway driver, Schneider Electric recommends using following mitigations to reduce the risk of exploit:• McAfee Application and Change Control software for application control. Refer to the Cybersecurity Application Note available https://www.se.com/ww/en/download/document/EIO0000004778/ • Follow workstation, network and site-hardening guidelines in the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/ww/en/download/document/7EN52-0390/) document. For customers not requiring the use of Uni-Telway driver, Schneider Electric recommends uninstalling the driver. Version 16.2 of EcoStruxureTM Control Expert, version 2025 of EcoStruxureTM Process Expert, version 2025 of EcoStruxureTM Process Expert for AVEVA System Platform, and version 3.63SP3 of OPC Factory Server do not include Uni-Telway driver by default anymore. This vulnerability is only affecting customers who have installed Uni-Telway driver.
Revisiegeschiedenis (4)
Initiële publicatie — 11 februari 2025
Original Release
Update A — 8 juli 2025
Mitigations section updated for EcoStruxure™ Control Expert and OPC Factory Server.
Update B — 13 januari 2026
Mitigations are now available for EcoStruxure™ Process Expert. EcoStruxure™ Process Expert found to be not affected by this vulnerability and advisory title has been modified
Update C — 10 februari 2026
Removed comment “EcoStruxure™ Process Expert found to be not affected by this vulnerability.