CISA + leveranciers
ICS Advisories
Advisories specifiek gericht op industriële besturingssystemen — van CISA ICS-CERT en rechtstreeks van leveranciers (onder meer Siemens, ABB, Schneider Electric, WAGO en Phoenix Contact) — inclusief revisiegeschiedenis (initiële publicatie, Update A, Update B) en gekoppelde CVE's.
1
Gevonden
Advisorydata: live koppeling— laatst opgehaald: 7 november 2026 om 00:32.
Filters
1 actief1 advisories gevonden
Gepubliceerd
9 maart 2020
Laatste update
22 mei 2025
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
The firmware update package (WUP) is not signed entirely. The used password offers no additional security, it is just meant to protect from unintentional modifications of the WUP file. Thus only the integrity of the signed firmware part (rauc file) is protected against intended manipulation. An attacker could manipulate the WUP file in a way that additional files with potentially malicious content are added to the WUP file. In case an authorized user that issues a firmware update could be tricked into installing this manipulated WUP file onto the device, the potentially malicious files would also be copied and installed on to the device and executed with elevated privileges.
Mitigatiesamenvatting
Execute FW-Update only as user 'admin'.
Revisiegeschiedenis (2)
Initiële publicatie — 9 maart 2020
initial revision
Update A — 22 mei 2025
Fix: version space, quotation mark