CISA + leveranciers
ICS Advisories
Advisories specifiek gericht op industriële besturingssystemen — van CISA ICS-CERT en rechtstreeks van leveranciers (onder meer Siemens, ABB, Schneider Electric, WAGO en Phoenix Contact) — inclusief revisiegeschiedenis (initiële publicatie, Update A, Update B) en gekoppelde CVE's.
1
Gevonden
Advisorydata: live koppeling— laatst opgehaald: 7 november 2026 om 13:52.
Filters
1 actief1 advisories gevonden
Gepubliceerd
10 november 2025
Laatste update
10 november 2025
Gekoppelde CVE's
Getroffen sectoren
Energieopwekking
Risk evaluation
A vulnerability was identified in the variTRON password generation algorithm of the debug-interface. The PRNG is initialized with the current Unix Timestamp, thus the resulting password is predictable. With the password root-access to the UART and ssh Interface can be gained. The impact is limited, since the debug-interface has to be actively enabled by an authorized user and will be deactivated automatically after the next reboot of the device.
Mitigatiesamenvatting
Update the affected products to version 9.0.2.5.
Revisiegeschiedenis (1)
Initiële publicatie — 10 november 2025
Release version.