Gepubliceerd
18 november 2026
Laatste update
18 november 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
An integer overflow vulnerability exists in the open-source repository sick_scan_xd (https://github.com/SICKAG/sick_scan_xd), a ROS 2 driver library and software development kit for SICK LiDAR and RADAR devices. A specially crafted network packet could cause an integer overflow during packet size validation, potentially bypassing boundary checks and resulting in out-of-bounds reads. If exploited, this vulnerability could affect the availability of applications using the affected library. SICK recommends applying the defined remediation for this vulnerability.
Mitigatiesamenvatting
Users are recommended to upgrade to version 3.10.0.
Revisiegeschiedenis (1)
Initiële publicatie — 18 november 2026
Initial version