CISA + leveranciers
ICS Advisories
Advisories specifiek gericht op industriële besturingssystemen — van CISA ICS-CERT en rechtstreeks van leveranciers (onder meer Siemens, ABB, Schneider Electric, WAGO en Phoenix Contact) — inclusief revisiegeschiedenis (initiële publicatie, Update A, Update B) en gekoppelde CVE's.
10
Gevonden
Advisorydata: live koppeling— laatst opgehaald: 20 november 2026 om 20:17.
Filters
1 actief10 advisories gevonden
Gepubliceerd
16 november 2026
Laatste update
16 november 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
The listed products from the Welotec RSAPC family are affected by PKfail. The affected UEFI firmware uses an insecure default Platform Key (PK), which undermines the trust established by UEFI Secure Boot.
Mitigatiesamenvatting
- Restrict physical access and local administrative access to affected devices to trusted personnel until the BIOS update has been installed.
Revisiegeschiedenis (1)
Initiële publicatie — 16 november 2026
Initial draft.
Gepubliceerd
16 november 2026
Laatste update
16 november 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
The Linux kernel used by the affected egOS releases contains a use-after-free vulnerability in the IPv4 TCP connection-handling path. An unauthenticated remote attacker can send specially crafted IPv4 TCP packets containing IP options to a listening service and race retransmitted connection requests against connection establishment or teardown. Successful exploitation may disclose or corrupt kernel memory, crash the device, or potentially allow arbitrary code execution with kernel privileges.
Mitigatiesamenvatting
- Do not expose egOS management interfaces or other TCP services directly to the internet or other untrusted networks. - Restrict inbound TCP access to trusted systems using network segmentation, firewall rules, or a VPN. - At a trusted upstream firewall, block inbound IPv4 TCP packets that contain IPv4 header options. Test this measure against operational requirements before deployment because it may disrupt traffic that legitimately uses IPv4 options. Standard TCP options are not affected. - Disable unused TCP services. If Multipath TCP is enabled, disable it where operationally possible. Disabling Multipath TCP reduces exposure to demonstrated remote code execution paths but does not fully mitigate the vulnerability. - Monitor affected devices for unexpected restarts, kernel faults, and anomalous inbound TCP traffic containing IPv4 options.
Revisiegeschiedenis (1)
Initiële publicatie — 16 november 2026
Initial release
Gepubliceerd
11 november 2026
Laatste update
11 november 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
The egOS system trust store uses certificate data from the Mozilla NSS root store. The trust store contains eMudhra emSign root certificates associated with eight compromised intermediate certificate authority keys. An unauthenticated attacker who possesses one of the compromised keys and can intercept relevant network traffic may issue fraudulent TLS certificates, impersonate remote services, and read or modify outgoing TLS traffic from the device.
Mitigatiesamenvatting
There is no supported customer-performable workaround for removing the affected certificates from the devices. Until the fixed egOS version can be installed, restrict egOS communication to trusted networks and use network segmentation or a trusted VPN where operationally possible. Prevent untrusted parties from gaining a man-in-the-middle position on network paths used by the affected devices. Monitor affected devices and connected services for unexpected TLS endpoints, certificate changes, and anomalous network activity.
Revisiegeschiedenis (1)
Initiële publicatie — 11 november 2026
Initial release.
Gepubliceerd
3 november 2026
Laatste update
3 november 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Multiple vulnerabilities in the web-based management functions of the affected Welotec routers, including VPN-related functions, may allow a remote attacker with high privileges to inject commands or trigger a buffer overflow. Successful exploitation may result in command execution with root privileges or a denial of service.
Mitigatiesamenvatting
Do not expose the management interface to the internet or other untrusted networks. Restrict management access to trusted administrator workstations using network segmentation and firewall rules.
Revisiegeschiedenis (1)
Initiële publicatie — 3 november 2026
Initial release.
Gepubliceerd
29 oktober 2026
Laatste update
29 oktober 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Two memory-safety vulnerabilities in the PHP runtime bundled with SMART EMS allow an unauthenticated remote attacker to execute arbitrary code in the context of the PHP web worker. All SMART EMS versions up to and including v3.5.3 are affected. Exploitability and reliability depend on the PHP server interface, configuration, application behaviour, and worker reuse.
Mitigatiesamenvatting
Do not expose the SMART EMS Web UI directly to the internet or other untrusted networks. Restrict access to trusted administrator workstations through network segmentation, firewall rules, or a VPN. Where operationally possible, enforce `memory_limit=-1` administratively and restart all PHP workers. Use a container or cgroup memory limit as an availability boundary and enforce conservative request-size, input, multipart-part, header, and nesting limits at the frontend. If multipart form data is not required, block such requests before they reach PHP. These measures reduce exposure to confirmed attack paths but are not a complete mitigation.
Revisiegeschiedenis (1)
Initiële publicatie — 29 oktober 2026
Initial release.
Gepubliceerd
10 september 2025
Laatste update
22 september 2025
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
A path traversal flaw in the SmartEMS upload handling allows authenticated users to direct upload data outside of the intended directory via the 'Upload-Key' header. In deployments where writable, code-interpreted paths are reachable, this may lead to remote code execution.
Mitigatiesamenvatting
Restrict access to the SmartEMS Web UI to trusted admin networks/VPN. Enforce strong credentials and rotate or revoke active tokens/sessions.
Revisiegeschiedenis (2)
Initiële publicatie — 10 september 2025
Initial revision.
Update A — 22 september 2025
Changes impact note categorie from details to description
Gepubliceerd
26 augustus 2025
Laatste update
26 augustus 2025
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
A hard-coded JWT secret in the egOS WebGUI backend is readable to the default user, allowing attackers to forge valid tokens and access protected API endpoints.
Mitigatiesamenvatting
Temporarily disable the WebGUI or restrict network access to the WebGUI to trusted admin stations.
Revisiegeschiedenis (1)
Initiële publicatie — 26 augustus 2025
initial version
Gepubliceerd
9 april 2024
Laatste update
14 mei 2025
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Welotec has closed two vulnerabilities in the TK500v1 router series and advises to update the routers to firmware version r5542 or later. An exploitation of the vulnerabilities can allow an attacker to manipulate the device.
Mitigatiesamenvatting
Update the product to firmware v2.3.0.r5542 or later.
Revisiegeschiedenis (4)
Initiële publicatie — 7 juni 2023
initial revision
Update A — 4 juni 2024
Minor typo changes. Reorder Products and Branches. Duplicate remediation from document notes to the vulnerabilities.
Update B — 6 november 2024
Fix: correct certvde domain, added self-reference
Update C — 14 mei 2025
Fix: firmware category, added distribution, version space
Gepubliceerd
22 augustus 2024
Laatste update
22 augustus 2024
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Products from the Edge Gateway Family are affected by recently published so called RegreSSHion vulnerability.
Mitigatiesamenvatting
Disable SSH Access via CLI Command or Config Import locally or for a centrally managed device by changing the configuration in SMART EMSRefer to eG OS manual chapter 4.26 for further information
Revisiegeschiedenis (1)
Initiële publicatie — 22 augustus 2024
Initial revision.
Risk evaluation
Welotec has been informed by an external source that the WebUI of the device management solution "SMART EMS" and the remote connectivity solution "VPN Security Suite" is vulnerable to so-called "Clickjacking" and advises to update to version v3.1.4 or later.
Mitigatiesamenvatting
This vulnerability can be mitigated with the use of an additional Reverse Proxy and / or Web Application Firewall protecting the WebUI.
Revisiegeschiedenis (1)
Initiële publicatie — 23 april 2024
Initial revision.