Kwetsbaarheden worden geladen…
Kwetsbaarheden worden geladen…
CVE-2021-32036
An authenticated user without any specific authorizations may be able to repeatedly invoke the features command where at a high volume may lead to resource depletion or generate high lock contention. This may result in denial of service and in rare cases could result in id field collisions. This issue affects MongoDB Server v5.0 versions prior to and including 5.0.3; MongoDB Server v4.4 versions prior to and including 4.4.9; MongoDB Server v4.2 versions prior to and including 4.2.16 and MongoDB Server v4.0 versions prior to and including 4.0.28
Dit record: live koppeling— laatst opgehaald: 24 september 2026 om 04:11.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
An authenticated user without any specific authorizations may be able to repeatedly invoke the features command where at a high volume may lead to resource depletion or generate high lock contention. This may result in denial of service and in rare cases could result in id field collisions. This issue affects MongoDB Server v5.0 versions prior to and including 5.0.3; MongoDB Server v4.4 versions prior to and including 4.4.9; MongoDB Server v4.2 versions prior to and including 4.2.16 and MongoDB Server v4.0 versions prior to and including 4.0.28
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L
Attack vector
NETWORK
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Geen
Integriteit
Beperkt
Beschikbaarheid
Beperkt
Kans op misbruik binnen 30 dagen
1.0%
Percentiel
62e
Bron: FIRST.org, bijgewerkt op 23 september 2026.
ABB recommends the following mitigation measures: - Replace bundled MongoDB with a supported version if IIoT services are required: - Where IIoT functionality is required, the bundled MongoDB instance can be replaced with a supported and patched version through manual configuration. - The following zenon online help section explains the process of installing and using your own MongoDB database: zenHelpViewer - Uninstall IIoT Services wherever it’s not required: - If IIoT Services are not required, they can be removed using the Control panel uninstaller. This eliminates the dependency on MongoDB without affecting other zenon components. Refer to section “General security recommendations” for further advise on how to keep your system secure.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 5.4, EPSS 1.0%, industriële relevantie 55/100.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Beperkte impact op beschikbaarheid; risico ligt vooral bij vertrouwelijkheid of integriteit van procesdata.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "ABB" is een bekende leverancier van apparatuur voor de energiesector.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 24 september 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.