CVE-2021-33532
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality. A specially crafted diagnostic script file name can cause user input to be reflected in a subsequent iw_system call, resulting in remote control over the device. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.
Dit record: live koppeling— laatst opgehaald: 7 november 2026 om 02:05.
Leverancier
Producten
IE-WL-BL-AP-CL-EU, IE-WL-BL-AP-CL-US, IE-WLT-BL-AP-CL-EU, IE-WLT-BL-AP-CL-US, IE-WLT-VL-AP-BR-CL-EU, IE-WLT-VL-AP-BR-CL-US en 2 meer
t/m versie <=V1.16.18 (Build 18081617)
Gepubliceerd
25 juni 2021
Laatst gewijzigd
17 juni 2026
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality. A specially crafted diagnostic script file name can cause user input to be reflected in a subsequent iw_system call, resulting in remote control over the device. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Hoog
Integriteit
Hoog
Beschikbaarheid
Hoog
Kans op misbruik binnen 30 dagen
1.7%
Percentiel
78e
Bron: FIRST.org, bijgewerkt op 6 november 2026.
For all potential vulnerabilities, customers can download a patched firmware to secure their Industrial WLAN devices properly. Please follow the procedure below to download and install the latest firmware for your device: 1. Use the link: [www.weidmueller.com](www.weidmueller.com) 2. Enter the product number of the Industrial WLAN device you want to update in the search field on the webpage and press "Enter". 3. On the next page, expand the drop-down menu **"Downloads"**. 4. Download the respective firmware from the download table. 5. Install the firmware on your device. Patched firmware versions for all affected products | Product number | Product name | Firmware version | |---------------|-----------------------------------|------------------------------------------| | 2536600000 | IE-WL-BL-AP-CL-EU | <= V1.16.21 (Build 21010513) | | 2536650000 | IE-WLT-BL-AP-CL-EU | <= V1.16.21 (Build 21010513) | | 2536660000 | IE-WL-BL-AP-CL-US | <= V1.16.21 (Build 21010513) | | 2536670000 | IE-WLT-BL-AP-CL-US | <= V1.16.21 (Build 21010513) | | 2536680000 | IE-WL-VL-AP-BR-CL-EU | <= V1.11.13 (Build 21010513) | | 2536690000 | IE-WLT-VL-AP-BR-CL-EU | <= V1.11.13 (Build 21010513) | | 2536700000 | IE-WL-VL-AP-BR-CL-US | <= V1.11.13 (Build 21010513) | | 2536710000 | IE-WLT-VL-AP-BR-CL-US | <= V1.11.13 (Build 21010513) | If a firmware update is available for your device, please follow the steps above to install it.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 8.8, EPSS 1.7%, industriële relevantie 40/100.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Mogelijk verlies van zicht op of besturing over het proces bij succesvol misbruik.
Geen sterke energiesector-specifieke signalen herkend; algemene OT/ICS-relevantie.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 7 november 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.