CVE-2024-56337
Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability in Apache Tomcat. This issue affects Apache Tomcat: from 11.0.0-M1 through 11.0.1, from 10.1.0-M1 through 10.1.33, from 9.0.0.M1 through 9.0.97. The following versions were EOL at the time the CVE was created but are known to be affected: 8.5.0 though 8.5.100. Other, older, EOL versions may also be affected. The mitigation for CVE-2024-50379 was incomplete. Users running Tomcat on a case insensitive file system with the default servlet write enabled (readonly initialisation parameter set to the non-default value of false) may need additional configuration to fully mitigate CVE-2024-50379 depending on which version of Java they are using with Tomcat: - running on Java 8 or Java 11: the system property sun.io.useCanonCaches must be explicitly set to false (it defaults to true) - running on Java 17: the system property sun.io.useCanonCaches, if set, must be set to false (it defaults to false) - running on Java 21 onwards: no further configuration is required (the system property and the problematic cache have been removed) Tomcat 11.0.3, 10.1.35 and 9.0.99 onwards will include checks that sun.io.useCanonCaches is set appropriately before allowing the default servlet to be write enabled on a case insensitive file system. Tomcat will also set sun.io.useCanonCaches to false by default where it can.
Dit record: live koppeling— laatst opgehaald: 24 september 2026 om 04:10.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability in Apache Tomcat. This issue affects Apache Tomcat: from 11.0.0-M1 through 11.0.1, from 10.1.0-M1 through 10.1.33, from 9.0.0.M1 through 9.0.97. The following versions were EOL at the time the CVE was created but are known to be affected: 8.5.0 though 8.5.100. Other, older, EOL versions may also be affected. The mitigation for CVE-2024-50379 was incomplete. Users running Tomcat on a case insensitive file system with the default servlet write enabled (readonly initialisation parameter set to the non-default value of false) may need additional configuration to fully mitigate CVE-2024-50379 depending on which version of Java they are using with Tomcat: - running on Java 8 or Java 11: the system property sun.io.useCanonCaches must be explicitly set to false (it defaults to true) - running on Java 17: the system property sun.io.useCanonCaches, if set, must be set to false (it defaults to false) - running on Java 21 onwards: no further configuration is required (the system property and the problematic cache have been removed) Tomcat 11.0.3, 10.1.35 and 9.0.99 onwards will include checks that sun.io.useCanonCaches is set appropriately before allowing the default servlet to be write enabled on a case insensitive file system. Tomcat will also set sun.io.useCanonCaches to false by default where it can.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Vertrouwelijkheid
Hoog
Integriteit
Hoog
Beschikbaarheid
Hoog
Kans op misbruik binnen 30 dagen
9.0%
Percentiel
95e
Bron: FIRST.org, bijgewerkt op 23 september 2026.
The problem is corrected in the following product versions: - APROL >= R 4.4-01P5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 9.8, EPSS 9.0%, industriële relevantie 55/100.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Mogelijk verlies van zicht op of besturing over het proces bij succesvol misbruik.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "B&R Industrial Automation GmbH" is een bekende leverancier van apparatuur voor de energiesector.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 24 september 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.