Kwetsbaarheden worden geladen…
Kwetsbaarheden worden geladen…
CVE-2025-37964
In the Linux kernel, the following vulnerability has been resolved: x86/mm: Eliminate window where TLB flushes may be inadvertently skipped tl;dr: There is a window in the mm switching code where the new CR3 is set and the CPU should be getting TLB flushes for the new mm. But should_flush_tlb() has a bug and suppresses the flush. Fix it by widening the window where should_flush_tlb() sends an IPI. Long Version: === History === There were a few things leading up to this. First, updating mm_cpumask() was observed to be too expensive, so it was made lazier. But being lazy caused too many unnecessary IPIs to CPUs due to the now-lazy mm_cpumask(). So code was added to cull mm_cpumask() periodically[2]. But that culling was a bit too aggressive and skipped sending TLB flushes to CPUs that need them. So here we are again. === Problem === The too-aggressive code in should_flush_tlb() strikes in this window: // Turn on IPIs for this CPU/mm combination, but only // if should_flush_tlb() agrees: cpumask_set_cpu(cpu, mm_cpumask(next)); next_tlb_gen = atomic64_read(&next->context.tlb_gen); choose_new_asid(next, next_tlb_gen, &new_asid, &need_flush); load_new_mm_cr3(need_flush); // ^ After 'need_flush' is set to false, IPIs *MUST* // be sent to this CPU and not be ignored. this_cpu_write(cpu_tlbstate.loaded_mm, next); // ^ Not until this point does should_flush_tlb() // become true! should_flush_tlb() will suppress TLB flushes between load_new_mm_cr3() and writing to 'loaded_mm', which is a window where they should not be suppressed. Whoops. === Solution === Thankfully, the fuzzy "just about to write CR3" window is already marked with loaded_mm==LOADED_MM_SWITCHING. Simply checking for that state in should_flush_tlb() is sufficient to ensure that the CPU is targeted with an IPI. This will cause more TLB flush IPIs. But the window is relatively small and I do not expect this to cause any kind of measurable performance impact. Update the comment where LOADED_MM_SWITCHING is written since it grew yet another user. Peter Z also raised a concern that should_flush_tlb() might not observe 'loaded_mm' and 'is_lazy' in the same order that switch_mm_irqs_off() writes them. Add a barrier to ensure that they are observed in the order they are written.
Dit record: live koppeling— laatst opgehaald: 24 september 2026 om 04:14.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
In the Linux kernel, the following vulnerability has been resolved: x86/mm: Eliminate window where TLB flushes may be inadvertently skipped tl;dr: There is a window in the mm switching code where the new CR3 is set and the CPU should be getting TLB flushes for the new mm. But should_flush_tlb() has a bug and suppresses the flush. Fix it by widening the window where should_flush_tlb() sends an IPI. Long Version: === History === There were a few things leading up to this. First, updating mm_cpumask() was observed to be too expensive, so it was made lazier. But being lazy caused too many unnecessary IPIs to CPUs due to the now-lazy mm_cpumask(). So code was added to cull mm_cpumask() periodically[2]. But that culling was a bit too aggressive and skipped sending TLB flushes to CPUs that need them. So here we are again. === Problem === The too-aggressive code in should_flush_tlb() strikes in this window: // Turn on IPIs for this CPU/mm combination, but only // if should_flush_tlb() agrees: cpumask_set_cpu(cpu, mm_cpumask(next)); next_tlb_gen = atomic64_read(&next->context.tlb_gen); choose_new_asid(next, next_tlb_gen, &new_asid, &need_flush); load_new_mm_cr3(need_flush); // ^ After 'need_flush' is set to false, IPIs *MUST* // be sent to this CPU and not be ignored. this_cpu_write(cpu_tlbstate.loaded_mm, next); // ^ Not until this point does should_flush_tlb() // become true! should_flush_tlb() will suppress TLB flushes between load_new_mm_cr3() and writing to 'loaded_mm', which is a window where they should not be suppressed. Whoops. === Solution === Thankfully, the fuzzy "just about to write CR3" window is already marked with loaded_mm==LOADED_MM_SWITCHING. Simply checking for that state in should_flush_tlb() is sufficient to ensure that the CPU is targeted with an IPI. This will cause more TLB flush IPIs. But the window is relatively small and I do not expect this to cause any kind of measurable performance impact. Update the comment where LOADED_MM_SWITCHING is written since it grew yet another user. Peter Z also raised a concern that should_flush_tlb() might not observe 'loaded_mm' and 'is_lazy' in the same order that switch_mm_irqs_off() writes them. Add a barrier to ensure that they are observed in the order they are written.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Hoog
Integriteit
Hoog
Beschikbaarheid
Hoog
Kans op misbruik binnen 30 dagen
0.2%
Percentiel
9e
Bron: FIRST.org, bijgewerkt op 23 september 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 7.8, EPSS 0.2%, industriële relevantie 55/100.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Mogelijk verlies van zicht op of besturing over het proces bij succesvol misbruik.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Siemens" is een bekende leverancier van apparatuur voor de energiesector.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 24 september 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.