Kwetsbaarheden worden geladen…
Kwetsbaarheden worden geladen…
CVE-2025-39724
In the Linux kernel, the following vulnerability has been resolved: serial: 8250: fix panic due to PSLVERR When the PSLVERR_RESP_EN parameter is set to 1, the device generates an error response if an attempt is made to read an empty RBR (Receive Buffer Register) while the FIFO is enabled. In serial8250_do_startup(), calling serial_port_out(port, UART_LCR, UART_LCR_WLEN8) triggers dw8250_check_lcr(), which invokes dw8250_force_idle() and serial8250_clear_and_reinit_fifos(). The latter function enables the FIFO via serial_out(p, UART_FCR, p->fcr). Execution proceeds to the serial_port_in(port, UART_RX). This satisfies the PSLVERR trigger condition. When another CPU (e.g., using printk()) is accessing the UART (UART is busy), the current CPU fails the check (value & ~UART_LCR_SPAR) == (lcr & ~UART_LCR_SPAR) in dw8250_check_lcr(), causing it to enter dw8250_force_idle(). Put serial_port_out(port, UART_LCR, UART_LCR_WLEN8) under the port->lock to fix this issue. Panic backtrace: [ 0.442336] Oops - unknown exception [#1] [ 0.442343] epc : dw8250_serial_in32+0x1e/0x4a [ 0.442351] ra : serial8250_do_startup+0x2c8/0x88e ... [ 0.442416] console_on_rootfs+0x26/0x70
Dit record: live koppeling— laatst opgehaald: 24 september 2026 om 04:10.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
In the Linux kernel, the following vulnerability has been resolved: serial: 8250: fix panic due to PSLVERR When the PSLVERR_RESP_EN parameter is set to 1, the device generates an error response if an attempt is made to read an empty RBR (Receive Buffer Register) while the FIFO is enabled. In serial8250_do_startup(), calling serial_port_out(port, UART_LCR, UART_LCR_WLEN8) triggers dw8250_check_lcr(), which invokes dw8250_force_idle() and serial8250_clear_and_reinit_fifos(). The latter function enables the FIFO via serial_out(p, UART_FCR, p->fcr). Execution proceeds to the serial_port_in(port, UART_RX). This satisfies the PSLVERR trigger condition. When another CPU (e.g., using printk()) is accessing the UART (UART is busy), the current CPU fails the check (value & ~UART_LCR_SPAR) == (lcr & ~UART_LCR_SPAR) in dw8250_check_lcr(), causing it to enter dw8250_force_idle(). Put serial_port_out(port, UART_LCR, UART_LCR_WLEN8) under the port->lock to fix this issue. Panic backtrace: [ 0.442336] Oops - unknown exception [#1] [ 0.442343] epc : dw8250_serial_in32+0x1e/0x4a [ 0.442351] ra : serial8250_do_startup+0x2c8/0x88e ... [ 0.442416] console_on_rootfs+0x26/0x70
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Geen
Integriteit
Geen
Beschikbaarheid
Hoog
Kans op misbruik binnen 30 dagen
0.2%
Percentiel
7e
Bron: FIRST.org, bijgewerkt op 23 september 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 5.5, EPSS 0.2%, industriële relevantie 55/100.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Mogelijk verlies van zicht op of besturing over het proces bij succesvol misbruik.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Siemens" is een bekende leverancier van apparatuur voor de energiesector.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 24 september 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.