CVE-2025-39773
In the Linux kernel, the following vulnerability has been resolved: net: bridge: fix soft lockup in br_multicast_query_expired() When set multicast_query_interval to a large value, the local variable 'time' in br_multicast_send_query() may overflow. If the time is smaller than jiffies, the timer will expire immediately, and then call mod_timer() again, which creates a loop and may trigger the following soft lockup issue. watchdog: BUG: soft lockup - CPU#1 stuck for 221s! [rb_consumer:66] CPU: 1 UID: 0 PID: 66 Comm: rb_consumer Not tainted 6.16.0+ #259 PREEMPT(none) Call Trace: <IRQ> __netdev_alloc_skb+0x2e/0x3a0 br_ip6_multicast_alloc_query+0x212/0x1b70 __br_multicast_send_query+0x376/0xac0 br_multicast_send_query+0x299/0x510 br_multicast_query_expired.constprop.0+0x16d/0x1b0 call_timer_fn+0x3b/0x2a0 __run_timers+0x619/0x950 run_timer_softirq+0x11c/0x220 handle_softirqs+0x18e/0x560 __irq_exit_rcu+0x158/0x1a0 sysvec_apic_timer_interrupt+0x76/0x90 </IRQ> This issue can be reproduced with: ip link add br0 type bridge echo 1 > /sys/class/net/br0/bridge/multicast_querier echo 0xffffffffffffffff > /sys/class/net/br0/bridge/multicast_query_interval ip link set dev br0 up The multicast_startup_query_interval can also cause this issue. Similar to the commit 99b40610956a ("net: bridge: mcast: add and enforce query interval minimum"), add check for the query interval maximum to fix this issue.
Dit record: live koppeling— laatst opgehaald: 24 september 2026 om 04:08.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
In the Linux kernel, the following vulnerability has been resolved: net: bridge: fix soft lockup in br_multicast_query_expired() When set multicast_query_interval to a large value, the local variable 'time' in br_multicast_send_query() may overflow. If the time is smaller than jiffies, the timer will expire immediately, and then call mod_timer() again, which creates a loop and may trigger the following soft lockup issue. watchdog: BUG: soft lockup - CPU#1 stuck for 221s! [rb_consumer:66] CPU: 1 UID: 0 PID: 66 Comm: rb_consumer Not tainted 6.16.0+ #259 PREEMPT(none) Call Trace: <IRQ> __netdev_alloc_skb+0x2e/0x3a0 br_ip6_multicast_alloc_query+0x212/0x1b70 __br_multicast_send_query+0x376/0xac0 br_multicast_send_query+0x299/0x510 br_multicast_query_expired.constprop.0+0x16d/0x1b0 call_timer_fn+0x3b/0x2a0 __run_timers+0x619/0x950 run_timer_softirq+0x11c/0x220 handle_softirqs+0x18e/0x560 __irq_exit_rcu+0x158/0x1a0 sysvec_apic_timer_interrupt+0x76/0x90 </IRQ> This issue can be reproduced with: ip link add br0 type bridge echo 1 > /sys/class/net/br0/bridge/multicast_querier echo 0xffffffffffffffff > /sys/class/net/br0/bridge/multicast_query_interval ip link set dev br0 up The multicast_startup_query_interval can also cause this issue. Similar to the commit 99b40610956a ("net: bridge: mcast: add and enforce query interval minimum"), add check for the query interval maximum to fix this issue.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Geen
Integriteit
Geen
Beschikbaarheid
Hoog
Kans op misbruik binnen 30 dagen
0.1%
Percentiel
2e
Bron: FIRST.org, bijgewerkt op 23 september 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 5.5, EPSS 0.1%, industriële relevantie 55/100.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Mogelijk verlies van zicht op of besturing over het proces bij succesvol misbruik.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Siemens" is een bekende leverancier van apparatuur voor de energiesector.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 24 september 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.