Kwetsbaarheden worden geladen…
Kwetsbaarheden worden geladen…
CVE-2025-40263
In the Linux kernel, the following vulnerability has been resolved: Input: cros_ec_keyb - fix an invalid memory access If cros_ec_keyb_register_matrix() isn't called (due to `buttons_switches_only`) in cros_ec_keyb_probe(), `ckdev->idev` remains NULL. An invalid memory access is observed in cros_ec_keyb_process() when receiving an EC_MKBP_EVENT_KEY_MATRIX event in cros_ec_keyb_work() in such case. Unable to handle kernel read from unreadable memory at virtual address 0000000000000028 ... x3 : 0000000000000000 x2 : 0000000000000000 x1 : 0000000000000000 x0 : 0000000000000000 Call trace: input_event cros_ec_keyb_work blocking_notifier_call_chain ec_irq_thread It's still unknown about why the kernel receives such malformed event, in any cases, the kernel shouldn't access `ckdev->idev` and friends if the driver doesn't intend to initialize them.
Dit record: live koppeling — laatst opgehaald: 25 juli 2026 om 01:35.
Leverancier
Siemens
Product
RUGGEDCOM RST2428P (6GK6242-6PA00)
Gepubliceerd
25 juli 2026
Laatst gewijzigd
25 juli 2026
In the Linux kernel, the following vulnerability has been resolved: Input: cros_ec_keyb - fix an invalid memory access If cros_ec_keyb_register_matrix() isn't called (due to `buttons_switches_only`) in cros_ec_keyb_probe(), `ckdev->idev` remains NULL. An invalid memory access is observed in cros_ec_keyb_process() when receiving an EC_MKBP_EVENT_KEY_MATRIX event in cros_ec_keyb_work() in such case. Unable to handle kernel read from unreadable memory at virtual address 0000000000000028 ... x3 : 0000000000000000 x2 : 0000000000000000 x1 : 0000000000000000 x0 : 0000000000000000 Call trace: input_event cros_ec_keyb_work blocking_notifier_call_chain ec_irq_thread It's still unknown about why the kernel receives such malformed event, in any cases, the kernel shouldn't access `ckdev->idev` and friends if the driver doesn't intend to initialize them.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Vertrouwelijkheid
Geen
Integriteit
Geen
Beschikbaarheid
Geen
Beperkte impact op beschikbaarheid; risico ligt vooral bij vertrouwelijkheid of integriteit van procesdata.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Siemens" is een bekende leverancier van apparatuur voor de energiesector.
Update to V4.0 or later version
IACS Radar-duiding
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 25 juli 2026.
IACS Radar-duiding
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.