Kwetsbaarheden worden geladen…
Kwetsbaarheden worden geladen…
CVE-2025-40271
In the Linux kernel, the following vulnerability has been resolved: fs/proc: fix uaf in proc_readdir_de() Pde is erased from subdir rbtree through rb_erase(), but not set the node to EMPTY, which may result in uaf access. We should use RB_CLEAR_NODE() set the erased node to EMPTY, then pde_subdir_next() will return NULL to avoid uaf access. We found an uaf issue while using stress-ng testing, need to run testcase getdent and tun in the same time. The steps of the issue is as follows: 1) use getdent to traverse dir /proc/pid/net/dev_snmp6/, and current pde is tun3; 2) in the [time windows] unregister netdevice tun3 and tun2, and erase them from rbtree. erase tun3 first, and then erase tun2. the pde(tun2) will be released to slab; 3) continue to getdent process, then pde_subdir_next() will return pde(tun2) which is released, it will case uaf access. CPU 0 | CPU 1 ------------------------------------------------------------------------- traverse dir /proc/pid/net/dev_snmp6/ | unregister_netdevice(tun->dev) //tun3 tun2 sys_getdents64() | iterate_dir() | proc_readdir() | proc_readdir_de() | snmp6_unregister_dev() pde_get(de); | proc_remove() read_unlock(&proc_subdir_lock); | remove_proc_subtree() | write_lock(&proc_subdir_lock); [time window] | rb_erase(&root->subdir_node, &parent->subdir); | write_unlock(&proc_subdir_lock); read_lock(&proc_subdir_lock); | next = pde_subdir_next(de); | pde_put(de); | de = next; //UAF | rbtree of dev_snmp6 | pde(tun3) / \ NULL pde(tun2)
Dit record: live koppeling — laatst opgehaald: 25 juli 2026 om 01:34.
Leverancier
Siemens
Product
RUGGEDCOM RST2428P (6GK6242-6PA00)
Gepubliceerd
25 juli 2026
Laatst gewijzigd
25 juli 2026
In the Linux kernel, the following vulnerability has been resolved: fs/proc: fix uaf in proc_readdir_de() Pde is erased from subdir rbtree through rb_erase(), but not set the node to EMPTY, which may result in uaf access. We should use RB_CLEAR_NODE() set the erased node to EMPTY, then pde_subdir_next() will return NULL to avoid uaf access. We found an uaf issue while using stress-ng testing, need to run testcase getdent and tun in the same time. The steps of the issue is as follows: 1) use getdent to traverse dir /proc/pid/net/dev_snmp6/, and current pde is tun3; 2) in the [time windows] unregister netdevice tun3 and tun2, and erase them from rbtree. erase tun3 first, and then erase tun2. the pde(tun2) will be released to slab; 3) continue to getdent process, then pde_subdir_next() will return pde(tun2) which is released, it will case uaf access. CPU 0 | CPU 1 ------------------------------------------------------------------------- traverse dir /proc/pid/net/dev_snmp6/ | unregister_netdevice(tun->dev) //tun3 tun2 sys_getdents64() | iterate_dir() | proc_readdir() | proc_readdir_de() | snmp6_unregister_dev() pde_get(de); | proc_remove() read_unlock(&proc_subdir_lock); | remove_proc_subtree() | write_lock(&proc_subdir_lock); [time window] | rb_erase(&root->subdir_node, &parent->subdir); | write_unlock(&proc_subdir_lock); read_lock(&proc_subdir_lock); | next = pde_subdir_next(de); | pde_put(de); | de = next; //UAF | rbtree of dev_snmp6 | pde(tun3) / \ NULL pde(tun2)
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Vertrouwelijkheid
Geen
Integriteit
Geen
Beschikbaarheid
Geen
Beperkte impact op beschikbaarheid; risico ligt vooral bij vertrouwelijkheid of integriteit van procesdata.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Siemens" is een bekende leverancier van apparatuur voor de energiesector.
Update to V4.0 or later version
IACS Radar-duiding
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 25 juli 2026.
IACS Radar-duiding
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.