In the Linux kernel, the following vulnerability has been resolved: can: gs_usb: gs_usb_receive_bulk_callback(): fix URB memory leak In gs_can_open(), the URBs for USB-in transfers are allocated, added to the parent->rx_submitted anchor and submitted. In the complete callback gs_usb_receive_bulk_callback(), the URB is processed and resubmitted. In gs_can_close() the URBs are freed by calling usb_kill_anchored_urbs(parent->rx_submitted). However, this does not take into account that the USB framework unanchors the URB before the complete function is called. This means that once an in-URB has been completed, it is no longer anchored and is ultimately not released in gs_can_close(). Fix the memory leak by anchoring the URB in the gs_usb_receive_bulk_callback() to the parent->rx_submitted anchor.
Dit record: live koppeling — laatst opgehaald: 25 juli 2026 om 01:42.
Leverancier
Siemens
Product
RUGGEDCOM RST2428P (6GK6242-6PA00)
Gepubliceerd
25 juli 2026
Laatst gewijzigd
25 juli 2026
In the Linux kernel, the following vulnerability has been resolved: can: gs_usb: gs_usb_receive_bulk_callback(): fix URB memory leak In gs_can_open(), the URBs for USB-in transfers are allocated, added to the parent->rx_submitted anchor and submitted. In the complete callback gs_usb_receive_bulk_callback(), the URB is processed and resubmitted. In gs_can_close() the URBs are freed by calling usb_kill_anchored_urbs(parent->rx_submitted). However, this does not take into account that the USB framework unanchors the URB before the complete function is called. This means that once an in-URB has been completed, it is no longer anchored and is ultimately not released in gs_can_close(). Fix the memory leak by anchoring the URB in the gs_usb_receive_bulk_callback() to the parent->rx_submitted anchor.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Vertrouwelijkheid
Geen
Integriteit
Geen
Beschikbaarheid
Geen
Beperkte impact op beschikbaarheid; risico ligt vooral bij vertrouwelijkheid of integriteit van procesdata.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Siemens" is een bekende leverancier van apparatuur voor de energiesector.
Update to V4.0 or later version
IACS Radar-duiding
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 25 juli 2026.
IACS Radar-duiding
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.