Kwetsbaarheden worden geladen…
Kwetsbaarheden worden geladen…
CVE-2026-43284
In the Linux kernel, the following vulnerability has been resolved: xfrm: esp: avoid in-place decrypt on shared skb frags MSG_SPLICE_PAGES can attach pages from a pipe directly to an skb. TCP marks such skbs with SKBFL_SHARED_FRAG after skb_splice_from_iter(), so later paths that may modify packet data can first make a private copy. The IPv4/IPv6 datagram append paths did not set this flag when splicing pages into UDP skbs. That leaves an ESP-in-UDP packet made from shared pipe pages looking like an ordinary uncloned nonlinear skb. ESP input then takes the no-COW fast path for uncloned skbs without a frag_list and decrypts in place over data that is not owned privately by the skb. Mark IPv4/IPv6 datagram splice frags with SKBFL_SHARED_FRAG, matching TCP. Also make ESP input fall back to skb_cow_data() when the flag is present, so ESP does not decrypt externally backed frags in place. Private nonlinear skb frags still use the existing fast path. This intentionally does not change ESP output. In esp_output_head(), the path that appends the ESP trailer to existing skb tailroom without calling skb_cow_data() is not reachable for nonlinear skbs: skb_tailroom() returns zero when skb->data_len is nonzero, while ESP tailen is positive. Thus ESP output will either use the separate destination-frag path or fall back to skb_cow_data().
Dit record: live koppeling— laatst opgehaald: 24 september 2026 om 04:14.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
In the Linux kernel, the following vulnerability has been resolved: xfrm: esp: avoid in-place decrypt on shared skb frags MSG_SPLICE_PAGES can attach pages from a pipe directly to an skb. TCP marks such skbs with SKBFL_SHARED_FRAG after skb_splice_from_iter(), so later paths that may modify packet data can first make a private copy. The IPv4/IPv6 datagram append paths did not set this flag when splicing pages into UDP skbs. That leaves an ESP-in-UDP packet made from shared pipe pages looking like an ordinary uncloned nonlinear skb. ESP input then takes the no-COW fast path for uncloned skbs without a frag_list and decrypts in place over data that is not owned privately by the skb. Mark IPv4/IPv6 datagram splice frags with SKBFL_SHARED_FRAG, matching TCP. Also make ESP input fall back to skb_cow_data() when the flag is present, so ESP does not decrypt externally backed frags in place. Private nonlinear skb frags still use the existing fast path. This intentionally does not change ESP output. In esp_output_head(), the path that appends the ESP trailer to existing skb tailroom without calling skb_cow_data() is not reachable for nonlinear skbs: skb_tailroom() returns zero when skb->data_len is nonzero, while ESP tailen is positive. Thus ESP output will either use the separate destination-frag path or fall back to skb_cow_data().
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Hoog
Integriteit
Hoog
Beschikbaarheid
Hoog
Kans op misbruik binnen 30 dagen
93.2%
Percentiel
100e
Bron: FIRST.org, bijgewerkt op 23 september 2026.
Disable the esp4 and esp6 modules [2]
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 8.8, EPSS 93.2%, industriële relevantie 55/100.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Mogelijk verlies van zicht op of besturing over het proces bij succesvol misbruik.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Hitachi Energy" is een bekende leverancier van apparatuur voor de energiesector.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 24 september 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.