CVE-2026-53012
In the Linux kernel, the following vulnerability has been resolved: nexthop: fix IPv6 route referencing IPv4 nexthop syzbot reported a panic [1] [2]. When an IPv6 nexthop is replaced with an IPv4 nexthop, the has_v4 flag of all groups containing this nexthop is not updated. This is because nh_group_v4_update is only called when replacing AF_INET to AF_INET6, but the reverse direction (AF_INET6 to AF_INET) is missed. This allows a stale has_v4=false to bypass fib6_check_nexthop, causing IPv6 routes to be attached to groups that effectively contain only AF_INET members. Subsequent route lookups then call nexthop_fib6_nh() which returns NULL for the AF_INET member, leading to a NULL pointer dereference. Fix by calling nh_group_v4_update whenever the family changes, not just AF_INET to AF_INET6. Reproducer: # AF_INET6 blackhole ip -6 nexthop add id 1 blackhole # group with has_v4=false ip nexthop add id 100 group 1 # replace with AF_INET (no -6), has_v4 stays false ip nexthop replace id 1 blackhole # pass stale has_v4 check ip -6 route add 2001:db8::/64 nhid 100 # panic ping -6 2001:db8::1 [1] https://syzkaller.appspot.com/bug?id=e17283eb2f8dcf3dd9b47fe6f67a95f71faadad0 [2] https://syzkaller.appspot.com/bug?id=8699b6ae54c9f35837d925686208402949e12ef3
Dit record: live koppeling— laatst opgehaald: 24 september 2026 om 04:10.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
In the Linux kernel, the following vulnerability has been resolved: nexthop: fix IPv6 route referencing IPv4 nexthop syzbot reported a panic [1] [2]. When an IPv6 nexthop is replaced with an IPv4 nexthop, the has_v4 flag of all groups containing this nexthop is not updated. This is because nh_group_v4_update is only called when replacing AF_INET to AF_INET6, but the reverse direction (AF_INET6 to AF_INET) is missed. This allows a stale has_v4=false to bypass fib6_check_nexthop, causing IPv6 routes to be attached to groups that effectively contain only AF_INET members. Subsequent route lookups then call nexthop_fib6_nh() which returns NULL for the AF_INET member, leading to a NULL pointer dereference. Fix by calling nh_group_v4_update whenever the family changes, not just AF_INET to AF_INET6. Reproducer: # AF_INET6 blackhole ip -6 nexthop add id 1 blackhole # group with has_v4=false ip nexthop add id 100 group 1 # replace with AF_INET (no -6), has_v4 stays false ip nexthop replace id 1 blackhole # pass stale has_v4 check ip -6 route add 2001:db8::/64 nhid 100 # panic ping -6 2001:db8::1 [1] https://syzkaller.appspot.com/bug?id=e17283eb2f8dcf3dd9b47fe6f67a95f71faadad0 [2] https://syzkaller.appspot.com/bug?id=8699b6ae54c9f35837d925686208402949e12ef3
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Geen
Integriteit
Geen
Beschikbaarheid
Hoog
Kans op misbruik binnen 30 dagen
0.1%
Percentiel
3e
Bron: FIRST.org, bijgewerkt op 23 september 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 5.5, EPSS 0.1%, industriële relevantie 60/100; opgehoogd wegens relevantie voor internet-exposure.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Mogelijk verlies van zicht op of besturing over het proces bij succesvol misbruik.
Beoordeeld als relevant voor de energiesector op basis van: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Leverancier "Siemens" is een bekende leverancier van apparatuur voor de energiesector. Beschrijving noemt industrieel protocol: https.
Dit product gebruikt protocollen die relevant zijn voor internet-exposure-analyse. Een internetbereikbare service is niet automatisch kwetsbaar.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Automatisch geclassificeerd als industrieel relevant op basis van CISA/NVD-signalen (zie redenen).
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 24 september 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.