Kwetsbaarheden worden geladen…
Kwetsbaarheden worden geladen…
CVE-2026-76287
In Splunk Enterprise versions below 10.4.4, a user that holds a role with the preview_data_management_pipeline capability or edit_data_management_pipeline_job capability could read or delete Data Management SPL2 preview jobs and results outside their ownership scope. The vulnerability is possible because the Data Management Representational State Transfer (REST) API verifies the required capability but does not verify that the requested preview job belongs to the requester. The affected Data Management REST API is available only when the Edge Processor feature is turned on. The Edge Processor feature is turned off by default. For more information see Set up a data management control plane (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/getting-started/set-up-a-data-management-control-plane) and Getting sample data for previewing data transformations (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/working-with-pipelines/getting-sample-data-for-previewing-data-transformations) in the Splunk documentation.
Dit record: live koppeling— laatst opgehaald: 8 november 2026 om 08:18.
Rechtstreeks overgenomen uit NVD, CISA of de leverancier — soms Engelstalig, ongewijzigd t.o.v. de bron.
In Splunk Enterprise versions below 10.4.4, a user that holds a role with the preview_data_management_pipeline capability or edit_data_management_pipeline_job capability could read or delete Data Management SPL2 preview jobs and results outside their ownership scope. The vulnerability is possible because the Data Management Representational State Transfer (REST) API verifies the required capability but does not verify that the requested preview job belongs to the requester. The affected Data Management REST API is available only when the Edge Processor feature is turned on. The Edge Processor feature is turned off by default. For more information see Set up a data management control plane (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/getting-started/set-up-a-data-management-control-plane) and Getting sample data for previewing data transformations (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/working-with-pipelines/getting-sample-data-for-previewing-data-transformations) in the Splunk documentation.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Attack vector
NETWORK
Privileges required
LOW
User interaction
NONE
Vertrouwelijkheid
Beperkt
Integriteit
Beperkt
Beschikbaarheid
Geen
Kans op misbruik binnen 30 dagen
0.2%
Percentiel
12e
Bron: FIRST.org, bijgewerkt op 7 november 2026.
Er is geen officiële patchinformatie beschikbaar op het moment van ophalen; raadpleeg de officiële bron.
Onze eigen Nederlandstalige interpretatie en context bij de brondata hierboven.
IACS Radar-duiding
Onze eigen interpretatie en context bij deze kwetsbaarheid — geen officiële bron.
IACS Radar-prioriteringsscore
Gebaseerd op CVSS 5.4, EPSS 0.2%, industriële relevantie 25/100; opgehoogd wegens relevantie voor internet-exposure.
Weegt CVSS, EPSS, KEV-status, industriële relevantie en exposure-relevantie samen — een aanvulling op, geen vervanging van, de losse scores hieronder en hierboven.
Voorwaarden voor misbruik
Operationele impact & energierelevantie
Beperkte impact op beschikbaarheid; risico ligt vooral bij vertrouwelijkheid of integriteit van procesdata.
Geen sterke energiesector-specifieke signalen herkend; algemene OT/ICS-relevantie.
Dit product gebruikt protocollen die relevant zijn voor internet-exposure-analyse. Een internetbereikbare service is niet automatisch kwetsbaar.
Aanbevolen defensieve maatregelen
Industriële relevantiescore
Classificatie is voorlopig; handmatige verificatie door een OT-securityanalist wordt aanbevolen.
Geclassificeerd door IACS Radar-analysepijplijn (geautomatiseerd) op 8 november 2026.
IEC 62443-mapping
Automatische IACS Radar-duiding op basis van de gerapporteerde CWE-zwakteclassificatie; geen officiële certificeringsuitspraak.