Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-81575
If configured as a server, CodeMeter Runtime before versions 8.41a and 9.10 accepts requests with opcode 0x5e, which contain the data length and the data itself. Missing bounds checking on the data length value can lead to out of bounds reads, causing a segmentation fault that ultimately crashes the CodeMeter Runtime.
This record: live connection— last retrieved: 24 September 2026 at 05:13.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
If configured as a server, CodeMeter Runtime before versions 8.41a and 9.10 accepts requests with opcode 0x5e, which contain the data length and the data itself. Missing bounds checking on the data length value can lead to out of bounds reads, causing a segmentation fault that ultimately crashes the CodeMeter Runtime.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.4%
Percentile
38e
Source: FIRST.org, updated on 23 September 2026.
For CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network server functionality at some point but no longer need it, disable it: - Open the Registry Editor and navigate to Computer\HKEY_LOCAL_MACHINE\SOFTWARE\ WIBUSYSTEMS\CodeMeter\Server\CurrentVersion\, then change the value of IsNetworkServerfrom 1 to 0. - Restart CodeMeter.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.5, EPSS 0.4%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "ABB" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping