FSA-202202

Festo: Controller CECC-S,LK,D family <= 2.3.8.1 - multiple vulnerabilities in CODESYS V3 runtime system

Festo — Controller CECC-D

Festo PSIRTkritiek

Risk evaluation

The Festo controller CECC product family is affected by multiple vulnerabilities in the CODESYS V3 runtime.

Mitigatiesamenvatting

For CVE-2019-5105, CVE-2019-9011, CVE-2019-9013, CVE-2020-10245, CVE-2020-12067, CVE-2020-12068, CVE-2020-12069, CVE-2020-15806, CVE-2021-29241, CVE-2021-29242, CVE-2021-33485, CVE-2021-36763, CVE-2021-36764, CVE-2022-22513, CVE-2022-22514, CVE-2022-22515, CVE-2022-22517, CVE-2022-22519: No fix planned. This issue will be handled with next hardware generation release.

Revisiegeschiedenis (4)
  1. Initiële publicatie — 18 juli 2022

    Initial revision.

  2. Update A — 11 januari 2024

    Adjust link to VDE Advisory, TLP and update some CVE information, where CVSS was not known before.

  3. Update B — 28 juli 2025

    Adjusted to VDE template. Changed title from 'Festo Controller CECC-S,-LK,-D Family Firmware <= 2.3.8.1 - Multiple Vulnerabilities in CODESYS V3 Runtime System' to 'Festo: Controller CECC-S,LK,D family <= 2.3.8.1 - multiple vulnerabilities in CODESYS V3 runtime system'. Updated legal disclaimer to add references to special provisions.

  4. Update C — 3 november 2025

    Add missing CWE values for vulnerabilities. Add missing CVSS 3.0 score for CVE-2010-5250.

Officiële bron: Festo PSIRT

FSA-202209

Festo: Incomplete documentation of remote accessible functions and protocols in Festo products

Festo — Bus module CPX-E-EP

Festo PSIRTkritiek

Gepubliceerd

29 november 2022

Laatste update

3 november 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Incomplete Festo product documentation of remote accessible functions and their required IP ports. Depending on the product a description of the supported features can be found in the product documentation to some extent. Update A, 2022-12-13 Added affected device "Bus module CPX-E-PN, 4080497"

Mitigatiesamenvatting

Update of technical user manual documentation in next product version.

Revisiegeschiedenis (4)
  1. Initiële publicatie — 29 november 2022

    Initial revision.

  2. Update A — 5 december 2022

    added bus module CPX-E-PN as affected product

  3. Update B — 6 april 2023

    adjusted technical user documentation to user documentation and fixed some typos.

  4. Update C — 3 november 2025

    Adjust link to VDE Advisory. Change title from "Incomplete User Documentation of Remote Accessible Functions and Protocols in Festo Products" to "Festo: Incomplete documentation of remote accessible functions and protocols in Festo products". Updated legal disclaimer to add references to special provisions.

Officiële bron: Festo PSIRT

FSA-202208

Festo: Multiple Festo products contain an unsafe default Codesys configuration

Festo — Compact Vision System SBO*-Q-*

Festo PSIRTkritiek

Gepubliceerd

29 november 2022

Laatste update

28 oktober 2025

Getroffen sectoren

Risk evaluation

The products are shipped with an unsafe configuration of the integrated CODESYS Runtime environment. In this case no default password is set to the CODESYS PLC and therefore access without authentication is possible. With a successful established connection to the CODESYS Runtime the PLC-Browser commands are available. Thus granting the possibilities to e.g. read and modify the configuration file(s), start/stop the application and reboot the device.

Mitigatiesamenvatting

Festo has identified the following compensatory measures to reduce the risk: - For CVE-2022-22515: Using the online user management prevents an attacker from downloading and execute malicious code, but also suppresses start, stop, debug, or other actions on a known working application that could potentially disrupt a machine or system.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 29 november 2022

    Initial revision.

  2. Update A — 11 januari 2024

    Adjust link to VDE Advisory

  3. Update B — 28 oktober 2025

    Adjusted to VDE template. Changed title from "Multiple Festo products contain an unsafe default Codesys configuration" to "Festo: Multiple Festo products contain an unsafe default Codesys configuration". Updated legal disclaimer to add references to special provisions.

Officiële bron: Festo PSIRT

PPSA-2025-004

Pilz: Vulnerability affecting PASvisu Runtime

Pilz — PMIv7xxe

Pilz PSIRThoog

Gepubliceerd

20 oktober 2025

Laatste update

20 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The PASvisu Runtime is affected by a vulnerability in a third-party component which can be exploited by a malicious web request.

Mitigatiesamenvatting

Limit network access to PASvisu server by using a firewall, a host-based firewall or similar measures.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 20 oktober 2025

    Initial Version

Officiële bron: Pilz PSIRT

VDE-2025-074

Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers

Phoenix Contact — CHARX SEC

Phoenix Contact PSIRThoog

Gepubliceerd

14 oktober 2025

Laatste update

15 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability in the firmware of CHARX SEC-3xxx charging controllers has been discovered.

Mitigatiesamenvatting

This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).

Revisiegeschiedenis (2)
  1. Initiële publicatie — 8 juli 2025

    Initial Revision

  2. Update A — 15 oktober 2025

    Updated the reporting credits, corrected reference token for one product, fixed typo in Document notes

Officiële bron: Phoenix Contact PSIRT

VDE-2025-091

Murrelektronik: Cleartext Transmission of Sensitive Information in IMPACT67 Pro

Murrelektronik — Impact67 Pro

Murrelektronik PSIRThoog

Gepubliceerd

14 oktober 2025

Laatste update

14 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The embedded web interface of the MURRELEKTRONIK IMPACT67 Pro PN DIO8 IOL8 transmits login credentials over unencrypted HTTP using a GET request. The device does not offer HTTPS/TLS support, exposing user credentials to passive interception by any attacker on the same network.

Mitigatiesamenvatting

Murrelektronik recommends: * Deactivating the Webserver will prevent any data from being sent unencrypted. More information on how to disable the webserver can be found in the manual. * Deactivating all unused network ports in the unit will prevent data sniffing. * Segmenting the network strictly helps to minimize unauthorized access to network traffic. If the webserver must stay activated, this is recommended to reduce the security breaches impact. * Advise users of the system to not use personal data or standard passwords for the webserver accounts. This helps to prevent personal data leakage.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 14 oktober 2025

    initial release

Officiële bron: Murrelektronik PSIRT

Advisory2025-08_VDE-2025-070

CODESYS Control V3 - NULL pointer dereference

CODESYS — CODESYS Control RTE (SL)

CODESYS PSIRThoog

Gepubliceerd

4 augustus 2025

Laatste update

14 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability in the CODESYS Control runtime system's CmpDevice component allows unauthenticated attackers to cause a denial-of-service (DoS) via specially crafted communication requests. The issue is triggered by a NULL pointer dereference and also affects systems when outdated CODESYS clients attempt to log in. Only PLCs based on the CODESYS Runtime Toolkit containing the components CmpDevice, CmpAuditLog, and CmpSessionInformation are impacted. **Update 1.1.0, 01.09.2025:** Updated remediation category - fixed SL runtimes are now available.

Mitigatiesamenvatting

The vulnerability can be mitigated by restricting the allowed login authentication type "CmpUserMgr/UserLogin_AuthenticationType" to "ONLY_ASYMMETRIC". This can be configured either via the Device Security Settings dialog in the CODESYS Development System or directly in the configuration file of the CODESYS Control runtime system (CODESYSControl.cfg) by adding the following setting: [CmpUserMgr] SECURITY.UserLogin_AuthenticationType=ONLY_ASYMMETRIC With this configuration in place, both potential attackers and legacy CODESYS protocol clients (prior to version 3.5.16.0) will be blocked from logging in, thereby preventing execution of the vulnerable code path.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 4 augustus 2025

    Initial revision.

  2. Update A — 1 september 2025

    Updated remediation category - fixed SL runtimes are now available.

  3. Update B — 14 oktober 2025

    List of affected and fixed products corrected regarding CODESYS HMI (SL) and CODESYS Runtime Toolkit

Officiële bron: CODESYS PSIRT

VDE-2025-072

Phoenix Contact: Security Advisory for QUINT4-UPS EIP

Phoenix Contact — QUINT4

Phoenix Contact PSIRThoog

Gepubliceerd

14 oktober 2025

Laatste update

14 oktober 2025

Getroffen sectoren

Risk evaluation

Multiple vulnerabilities were discovered in the firmware of QUINT4-UPS EIP devices that can be used by an unauthenticated remote attacker to perform Denial of Service attacks and to gather login credentials for the Webfrontend.

Mitigatiesamenvatting

This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). In the industrial sector it is common practice to use Modbus/TCP without authentication.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 14 oktober 2025

    Initial revision.

Officiële bron: Phoenix Contact PSIRT

FSA-202206

Festo: Vulnerable WIBU-SYSTEMS CodeMeter Runtime in multiple products

Festo — CIROS

Festo PSIRThoog

Gepubliceerd

13 december 2022

Laatste update

1 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability was reported in WIBU-SYSTEMS CodeMeter Runtime. WIBU-SYSTEMS CodeMeter Runtime is part of the installation packages of several Festo products.FluidDraw < 6.2c and CIROS <= 7.0.6 contain a vulnerable version of WIBU-SYSTEMS CodeMeter Runtime.

Mitigatiesamenvatting

FluidDraw P5, FluidDraw P6 Avoid any FluidDraw installation with a FluidDraw installation package below version 6.2c. Updated versions of FluidDraw are available on the Festo website. In case of a FluidDraw installation package with a version below 6.2c, do not use the WIBU CodeMeter package, that is part of the FluidDraw installation package. Skip the CodeMeter installation step during the FluidDraw installation and instead use a current CodeMeter version from the WIBU website and install that separately. In case of an already installed vulnerable CodeMeter version, update all of these WIBU CodeMeter installations with the current version of WIBU CodeMeter. Please refer to the WIBU CodeMeter documentation and website for further details and mitigations on usage of WIBU CodeMeter Runtime before 7.30a. CIROS For future installations, ensure you're using a CIROS installer downloaded from https://ip.festo-didactic.com/ Infoportal/CIROS/EN/Download.html after September 15, 2022. For existing installations, update the WIBU CodeMeter Runtime separately with at least version 7.30a downloaded from the WIBU Systems website. Please refer to the WIBU CodeMeter documentation and website for further details and mitigations on usage of WIBU CodeMeter Runtime before 7.30a. MES PC If your copy of MES4 came preinstalled on a PC shipped before December 2022, you'll need to make sure this PC has at least CodeMeter Runtime 7.30a installed. If necessary, download the update from the WIBU Systems website. Additional to the above: Festo strongly recommends to restrict unprivileged access to machines running Festo software and to minimize and protect network access to connected devices with state of the art techniques and processes. For a secure operation follow the recommendations in the product manuals.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 13 december 2022

    Initial revision.

  2. Update A — 11 januari 2024

    Adjust link to VDE Advisory

  3. Update B — 1 oktober 2025

    Adjusted to VDE template. Changed title from "Vulnerable WIBU-SYSTEMS CodeMeter Runtime in multiple Festo products" to "Festo: Vulnerable WIBU-SYSTEMS CodeMeter Runtime in multiple products".

Officiële bron: Festo PSIRT

FSA-202304

Festo: MSE6-C2M/D2M/E2M Incomplete User Documentation of Remote Accessible Functions

Festo — MSE6

Festo PSIRThoog

Gepubliceerd

5 september 2023

Laatste update

1 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Incomplete user documentation of undocumented, authenticated test mode and further remote accessible functions. The supported features may be covered only partly by the corresponding user documentation. Festo developed the products according to the respective state of the art. As a result, the protocols used no longer fully meet today's security requirements. The products are designed and developed for use in sealed-off (industrial) networks. If the network is not adequately sealed off, unauthorized access to the product can cause damage or malfunctions, particularly Denial of Service (DoS) or loss of integrity.

Mitigatiesamenvatting

Update of user documentation in next product version.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 5 september 2023

    Initial revision.

  2. Update A — 1 oktober 2025

    Adjusted to VDE template. Changed title from "MSE6-C2M/D2M/E2M Incomplete User Documentation of Remote Accessible Functions" to "Festo: MSE6-C2M/D2M/E2M Incomplete User Documentation of Remote Accessible Functions".

Officiële bron: Festo PSIRT

FSA-202301

Festo: Cross-Site-Scripting (XSS) vulnerability in LX-Appliance

Festo — LX Appliance

Festo PSIRTmiddel

Gepubliceerd

29 augustus 2023

Laatste update

1 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability in the Video.js package could allow a user of LX Appliance, with a high privilege account (i.e., with the "Teacher" role), to craft a malicious course and launch an XSS attack.

Mitigatiesamenvatting

Contact Festo Didactic services department at services.didactic@festo.com to update your LX Appliance to the latest version.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 29 augustus 2023

    Initial revision.

  2. Update A — 1 oktober 2025

    Adjusted to VDE template. Changed title from "Video.js Cross-Site-Scripting (XSS) vulnerability in LX Appliance" to "Festo: Cross-Site-Scripting (XSS) vulnerability in LX-Appliance".

Officiële bron: Festo PSIRT

VDE-2018-003

PHOENIX CONTACT: addressing Meltdown and Spectre vulnerabilities

Phoenix Contact — AXC 3051

Phoenix Contact PSIRTmiddel

Gepubliceerd

23 maart 2018

Laatste update

1 oktober 2025

Getroffen sectoren

Risk evaluation

Several CPUs manufactured by Intel, AMD or based on ARM technology may leak information due to their internal operation if attacked by specifically written software executed on the affected systems. The information in this advisory is based on the statements of respective manufacturers.

Mitigatiesamenvatting

On Industrial PCs and HMIs that operate with user installable or upgradable operating systems (mainly Windows) the latest version or update may be installed if required in the use case. As the update may have a performance impact, the application should be tested accordingly.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 23 maart 2018

    Initial revision.

  2. Update A — 14 mei 2025

    Fix: added distribution

  3. Update B — 1 oktober 2025

    Expressions errors were corrected in the acknowledgements.

Officiële bron: Phoenix Contact PSIRT

FSA-202303

Festo: Vulnerable Siemens TIA-Portal in multiple Festo Didactic products

Festo — MES PC

Festo PSIRThoog

Gepubliceerd

17 oktober 2023

Laatste update

1 oktober 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability was reported in Siemens TIA Portal. TIA Portal is part of the installation packages of several Festo Didactic products. TP 260 before June 2023 and MES PC based on DELL XE3 contain a vulnerable versions of TIA Portal V15 to V18. Affected products of TIA Portal contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system.

Mitigatiesamenvatting

Update TIA-Portal. Please refer to Siemens SSA-116924 for more details.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 17 oktober 2023

    Initial revision.

  2. Update A — 1 oktober 2025

    Adjusted to VDE template. Changed title from "Vulnerable Siemens TIA-Portal in several Festo Didactic Products" to "Festo: Vulnerable Siemens TIA-Portal in multiple Festo Didactic products".

Officiële bron: Festo PSIRT

VDE-2025-087

WAGO: Vulnerabilities in Device Sphere and Solution Builder

WAGO — Device Sphere

WAGO PSIRTkritiek

Gepubliceerd

24 september 2025

Laatste update

24 september 2025

Getroffen sectoren

Risk evaluation

Due to a missing authentication check, the WAGO Solution Builder and the WAGO Device Sphere are vulnerable to a potential information exposure.

Mitigatiesamenvatting

Please upgrade to the specified version or a later one of the WAGO Device Sphere or the WAGO Solution Builder.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 24 september 2025

    Initial Release.

Officiële bron: WAGO PSIRT

VDE-2018-013

WAGO: 750-8xx Controller Denial of Service

WAGO — PFC100

WAGO PSIRThoog

Gepubliceerd

17 augustus 2018

Laatste update

22 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The 750-8xx controller are susceptible to a Denial-of-Service attack due to a flood of network packets. Please consult the original paper for details (link at the bottom of this advisory).

Mitigatiesamenvatting

We recommend to operate the devices in closed networks or protect with a firewall against unauthorized access. Another, recommended mitigation is to limit the network traffic via the switch rate limit feature according to your application needs. The switch rate limit can be configured e.g. via Web based Management to minimize the effect of high network load: 750-8xx: Ethernet > "Misc. Configuration" > "internal Port" > "Output Limit Rate" 750-8xxx: Network > Ethernet > 'Switch Configuration' > 'Rate Limit' Please also consult the product manuals as this is a known problem for some devices: 750-880 Go to https://www.wago.com/de/sps/controller-ethernet/p/750-880 external link Select "Downloads" In section "Dokumentation" choose "ETHERNET Programmierbarer Feldbuscontroller 10 / 100 Mbit/s; digitale und analoge Signale V 2.3.0, 03.08.2016" and select your language for the manual. See section 9.3: Functional Restrictions and Limits 750-889 Go to https://www.wago.com/de/sps/controller-ethernet/p/750-889 external link Select "Downloads" In section "Dokumentation" choose "Controller KNX IP KNX IP Controller V 1.0.2, 04.10.2016" and select your language for the manual. See section 10.4: Functional Restrictions and Limits 750-831 Go to https://www.wago.com/de/sps/controller-ethernet/p/750-831 external link Select "Downloads" In section "Dokumentation" choose "BACnet/IP Programmierbarer Feldbuscontroller 10/100 Mbit/s; digitale und analoge Signale V 1.2.1, 20.02.2017" and select your language for the manual. See section 9.5: Functional Restrictions and Limits

Revisiegeschiedenis (4)
  1. Initiële publicatie — 17 augustus 2018

    Initial revision.

  2. Update A — 16 januari 2025

    Update: add CVE

  3. Update B — 22 mei 2025

    Fix: version space, added distribution, quotation mark

  4. Update C — 22 september 2025

    Fix in CVE Number

Officiële bron: WAGO PSIRT

VDE-2025-085

Welotec: Path Traversal in SmartEMS Upload Handling

Welotec — SmartEMS

Welotec PSIRThoog

Gepubliceerd

10 september 2025

Laatste update

22 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A path traversal flaw in the SmartEMS upload handling allows authenticated users to direct upload data outside of the intended directory via the 'Upload-Key' header. In deployments where writable, code-interpreted paths are reachable, this may lead to remote code execution.

Mitigatiesamenvatting

Restrict access to the SmartEMS Web UI to trusted admin networks/VPN. Enforce strong credentials and rotate or revoke active tokens/sessions.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 10 september 2025

    Initial revision.

  2. Update A — 22 september 2025

    Changes impact note categorie from details to description

Officiële bron: Welotec PSIRT

VDE-2025-083

WAGO: Vulnerability in hardware switch circuit

WAGO — Edge Controller

WAGO PSIRTmiddel

Gepubliceerd

15 september 2025

Laatste update

15 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The vulnerability in the Ethernet switch circuit is caused by a PullUp resistor at the reset input, leading to premature activation and undefined operation. Switching to a PullDown resistor keeps the switch in reset. This issue affects the CC100, the Touch Panels 600 and the Edge Controller.

Mitigatiesamenvatting

To address this vulnerability, it is recommended to utilize a newer hardware revision equipped with Firmware 04.08.05 (FW30). This firmware version is designed to resolve the issue by properly managing the switch activation and configuration process on the revised hardware. It is important to note that older firmware versions will not resolve the problem on the new hardware revision, and therefore upgrading both the hardware and firmware is necessary for an effective remediation.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 15 september 2025

    Initial revision.

Officiële bron: WAGO PSIRT

VDE-2025-080

WAGO: Multiple Vulnerabilities in I/O-Check Service

WAGO — CC100

WAGO PSIRTkritiek

Gepubliceerd

9 september 2025

Laatste update

9 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A missing authentication vulnerability exists in the iocheckd service "I/O-Check" functionality. A single packet can cause a denial of service and weaken credentials resulting in the default documented credentials being applied to the device. An attacker can send an unauthenticated packet to trigger this vulnerability.

Mitigatiesamenvatting

The I/O-Check service protocol is only needed during installation and commissioning, not during normal operations. It is highly recommended to disable the IP-port 6626 after commissioning.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 9 september 2025

    Initial revision.

Officiële bron: WAGO PSIRT

VDE-2025-077

Phoenix Contact: Two vulnerabilities in the jq JSON processor utilized by FL MGUARD 110x devices

Phoenix Contact — FL MGUARD 1102

Phoenix Contact PSIRThoog

Gepubliceerd

9 september 2025

Laatste update

9 september 2025

Getroffen sectoren

Risk evaluation

The jq JSON processor, which is used to migrate firmware configurations in the product, contains 2 vulnerabilities that can be exploited by an authenticated attacker.

Mitigatiesamenvatting

Phoenix Contact strongly recommends upgrading affected mGuard devices to firmware version 1.8.1 or higher which fixes this vulnerability.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 4 augustus 2025

    Initial revision.

Officiële bron: Phoenix Contact PSIRT

VDE-2025-075

Beckhoff: Deserialization of untrusted data by TwinCAT 3 Engineering

Beckhoff — TE1000 | TwinCAT 3 Enineering

Beckhoff PSIRThoog

Gepubliceerd

9 september 2025

Laatste update

9 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Beckhoff's TwinCAT 3 Engineering software is intented to craft automation projects consisting of a set of files which are stored locally as files underneath an individual folder or in a packed file. The TwinCAT 3 Engineering stores user settings and preferences among the non packed local files which are relevant to continue former work on the project conventienly. TwinCAT 3 Engineering stores such settings in files which are called "Solution User Options (.suo) File". When such settings are manipulated or crafted by an adversary in a specific way then TwinCAT 3 Engineering executes arbitrary commands as determined by these settings when the user uses TwinCAT 3 Engineering to open the project. These arbitrary commands are executed in the user context. Please note that solution user option files should not be checked in to source code control. This is also a best practice when working with source code projects and solutions. For example, see https://learn.microsoft.com/en-us/visualstudio/extensibility/internals/solution-user-options-dot-suo-file and https://infosys.beckhoff.com/content/1033/tc3_sourcecontrol/14604066827.html. The vulnerability is similar to older vulnerabilities that were addressed in the CODESYS Development System V3 product from CODESYS GmbH with CVE-2021-21864, CVE-2021-21865, CVE-2021-21866, CVE-2021-21867, CVE-2021-21868, CVE-2021-21869, and the associated Advisory 2021-13 from CODESYS GmbH.

Mitigatiesamenvatting

Please update to a recent version of the affected product and uninstall older versions of TwinCAT 3 Engineering. Make sure that older versions of TwinCAT 3 Engineering do not occur as "Remote Manager" versions, see https://infosys.beckhoff.com/content/1033/tc3_remote_manager/index.html?id=1584127271344589360. Remove the "pinning" from your projects to older versions of TwinCAT 3 Engineering, if present, see https://infosys.beckhoff.com/content/1033/tc3_remote_manager/3154642571.html.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 9 september 2025

    initial revision

Officiële bron: Beckhoff PSIRT

VDE-2025-064

Phoenix Contact: Products utilizing WIBU-SYSTEMS CodeMeter Runtime Windows Installer have a privilege escalation

Phoenix Contact — CodeMeter Runtime licensed Software

Phoenix Contact PSIRThoog

Gepubliceerd

9 september 2025

Laatste update

9 september 2025

Gekoppelde CVE's

Getroffen sectoren

Control centres

Risk evaluation

A local privilege escalation vulnerability in Phoenix Contact products utilizing WIBU-SYSTEMS CodeMeter Runtime allows users to gain admin rights on freshly installed systems. The CodeMeter Control Center starts with elevated privileges and retains them until restarted, enabling unauthorized access to admin tools like cmd.exe.

Mitigatiesamenvatting

PHOENIX CONTACT strongly recommends affected users to upgrade to CodeMeter V8.30a, which fixes these vulnerabilities. WIBU-SYSTEMS has already published this update for CodeMeter on their homepage. Since this current version of CodeMeter V8.30a has not yet been incorporated into Phoenix Contact products, we strongly recommend to download and install the current CodeMeter version directly from the WIBU-SYSTEMS homepage. Additional Recommendations: Regularly check the product's official webpage for updated release versions that support CodeMeter V8.30a. Update the Activation Wizard to version 1.8 as soon as it becomes available on the product's download page.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 9 september 2025

    Initial

Officiële bron: Phoenix Contact PSIRT

VDE-2025-048

WAGO: Escalation of Privileges in Coupler Firmware

WAGO — 750 Fieldbus Coupler

WAGO PSIRThoog

Gepubliceerd

8 september 2025

Laatste update

8 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A design flaw in the file system management exposes internal system partitions - intended to be hidden - during brief moments when they are mounted by the firmware. These partitions contain sensitive data such as firmware and certificates. Although access to the file system is mediated by a Nucleus layer that supports permission control, these permissions are currently not enforced. As a result, services like FTP/SFTP may inadvertently gain access to critical internal resources, increasing the risk of unauthorized access or data leakage.

Mitigatiesamenvatting

Update to Firmware version 13.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 8 september 2025

    initial version

Officiële bron: WAGO PSIRT

VDE-2025-082

WAGO: Critical sudo Vulnerability in Multiple Products

WAGO — CC100

WAGO PSIRThoog

Gepubliceerd

8 september 2025

Laatste update

8 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability in sudo allows a low privileged attacker to execute commands with root rights.

Mitigatiesamenvatting

Update to Firmware version 04.08.01 (FW30) or higher.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 8 september 2025

    Initial revision.

Officiële bron: WAGO PSIRT

VDE-2025-061

Bender Charge Controller Vulnerability - Disclosure Of Stored Credentials When Authenticated

Bender — CC612

Bender PSIRThoog

Gepubliceerd

8 september 2025

Laatste update

8 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Bender is publishing this advisory to inform customers about a security vulnerability in the Charge Controller product families. Bender has analyzed the weakness and determined that the electrical safety of the devices is not affected. Bender considers the weakness to be of high risk and it should be patched immediately.

Mitigatiesamenvatting

Install software update 5.33.3 or later.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 8 september 2025

    initial version

Officiële bron: Bender PSIRT

VDE-2025-084

Bender Charge Controller Vulnerability - Unsecure Communication

Bender — CC612

Bender PSIRThoog

Gepubliceerd

8 september 2025

Laatste update

8 september 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Bender is publishing this advisory to inform customers about a security vulnerability in the Charge Controller product families. Bender has analyzed the weakness and determined that the electrical safety of the devices is not affected. Bender considers the weakness to be of high risk and it should be patched immediately.

Mitigatiesamenvatting

Enable use of HTTPS in the charge controller configuration Web UI settings>system>https

Revisiegeschiedenis (1)
  1. Initiële publicatie — 8 september 2025

    initial version

Officiële bron: Bender PSIRT