VDE-2025-024

Wiesemann & Theis: Multiple products from Wiesemann & Theis support deprecated jQuery version

Wiesemann & Theis — USB-Server Industry Isochron

Wiesemann & Theis PSIRTmiddel

Gepubliceerd

13 mei 2025

Laatste update

13 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Multiple W&T devices are shipped with a jQuery version with a known XSS vulnerability.

Mitigatiesamenvatting

Access to the WBM should be limited to trustworthy networks or peers.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 13 mei 2025

    Initial revision

Officiële bron: Wiesemann & Theis PSIRT

VDE-2025-032

Wiesemann & Theis: Multiple W&T Products are vulnerable to cross-site-scripting

Wiesemann & Theis — Web-IO Analog-In/Out 0/4..20mA PoE

Wiesemann & Theis PSIRTmiddel

Gepubliceerd

6 mei 2025

Laatste update

6 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Multiple W&T Products are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via crafted payloads injected into several input fields of the configuration webpage.

Mitigatiesamenvatting

Access to the WBM should be limited to trustworthy networks or peers.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 6 mei 2025

    Initial revision

Officiële bron: Wiesemann & Theis PSIRT

VDE-2025-031

Wiesemann & Theis: Multiple products from Wiesemann & Theis support deprecated TLS protocol versions

Wiesemann & Theis — Com-Server ++

Wiesemann & Theis PSIRTkritiek

Gepubliceerd

28 april 2025

Laatste update

28 april 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Com-Server firmware versions prior to 1.60 support the insecure TLS 1.0 and TLS 1.1 protocols, which are susceptible to man-in-the-middle attacks and thereby compromise the confidentiality and integrity of data.

Mitigatiesamenvatting

Access to the WBM should be limited to trustworthy networks or peers.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 28 april 2025

    Initial revision

Officiële bron: Wiesemann & Theis PSIRT

VDE-2020-021

Endress+Hauser: Ecograph T utilizing Webserver firmware version 1.x suffers from improper privilege management

Endress+Hauser — Ecograph T Neutral/Private Label

Endress+Hauser PSIRThoog

Gepubliceerd

19 november 2020

Laatste update

11 april 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The affected device has a web-based user interface with a role-based access system. Users with different roles have different write and read privileges. The access system is based on dynamic "tokens".

Mitigatiesamenvatting

Customers should configure a perimeter firewall to block traffic from untrusted networks and users to the device. These recommendations will be incorporated into the device documentation (operating instructions). Change default password for operator, service and admin account. Endress+Hauser will not change this behavior. Customers are recommended to take the measures for Temporary Fix / Mitigation as described above.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 19 november 2020

    Initial revision.

  2. Update A — 11 april 2025

    Fix: version range

Officiële bron: Endress+Hauser PSIRT

VDE-2024-064

Beckhoff: Local command injection via TwinCAT Package Manager

Beckhoff — TwinCAT Package Manager

Beckhoff PSIRTmiddel

Gepubliceerd

31 oktober 2024

Laatste update

11 april 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Beckhoff's TwinCAT 3.1 Build 4026 software is modularized and is installed with different packages depending on user requirements. These packages are selected and installed using either the command line utility tcpkg or the corresponding graphical user interface called TwinCAT Package Manager. Both use the same configuration that specifies where to load packages from. These locations are called feeds, have preconfigured default settings and can be customized by administrative users, for example to add another local mirror of a package server. When using the TwinCAT Package Manager on a PC, a user with administrative access rights can locally set a specially crafted URL for a feed that causes the TwinCAT Package Manager to execute arbitrary operating system commands.

Mitigatiesamenvatting

Administrative users shall always act thoroughly and inspect the values which they enter.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 31 oktober 2024

    initial revision

  2. Update A — 16 januari 2025

    Fix: list of branches, references

  3. Update B — 11 april 2025

    Fix: version range

Officiële bron: Beckhoff PSIRT

VDE-2023-050

Pilz: Vulnerability in PASvisu and PMI v8xx

Pilz — PMI v8xx

Pilz PSIRThoog

Gepubliceerd

30 januari 2024

Laatste update

10 april 2025

Getroffen sectoren

Risk evaluation

Multiple Pilz products are affected by stored cross-site-scripting (XSS) vulnerabilities. The vulnerabilities may enable an attacker to gain full control over the system. Update: 27.02.2024 Fix typo in advisory title

Mitigatiesamenvatting

* Only use project files from trustworthy sources. * Protect project files against modification by unauthorized users. * PASvisu Runtime: Limit network access to legitimate connections by using a firewall or similar measures. Use password protection on the online project.

Revisiegeschiedenis (4)
  1. Initiële publicatie — 30 januari 2024

    Initial revision.

  2. Update A — 27 februari 2024

    Updated Title.

  3. Update B — 6 november 2024

    Fix: correct certvde domain, added self-reference

  4. Update C — 10 april 2025

    fixed version operators

Officiële bron: Pilz PSIRT

VDE-2024-040

Multiple TRUMPF products prone to regreSSHion OpenSSH server vulnerabilities

TRUMPF — TruPulse

TRUMPF PSIRThoog

Gepubliceerd

25 juni 2024

Laatste update

10 april 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

TruControl laser control software prior to version 1.60.0 uses an OpenSSH server version affected by CVE-2024-6387. The affected OpenSSH Server version could potentially lead to a remote code execution.

Mitigatiesamenvatting

Update to first fixed version 1.06.00 or ideally to the newest release 04.04.00

Revisiegeschiedenis (4)
  1. Initiële publicatie — 25 juni 2024

    Initial revision.

  2. Update A — 6 november 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 14 november 2024

    removed issuing authority as it is the same as the publisher

  4. Update C — 10 april 2025

    Fixed CSAF self-reference URL

Officiële bron: TRUMPF PSIRT

VDE-2024-034

Multiple TRUMPF products prone to nftables server vulnerabilities

TRUMPF — Laser SE TruPulse

TRUMPF PSIRThoog

Gepubliceerd

25 juni 2024

Laatste update

10 april 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

TruControl laser control software from versions 3.50.0 to 4.00.0.B use Linux kernel versions affected by CVE-2024-1086. The affected kernel vulnerability could lead to local privilege escalation.

Mitigatiesamenvatting

• Update to the new release 4.04.0 of the TruControl software version

Revisiegeschiedenis (3)
  1. Initiële publicatie — 25 juni 2024

    Initial revision.

  2. Update A — 6 november 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 10 april 2025

    Fixed CSAF self-reference URL

Officiële bron: TRUMPF PSIRT

VDE-2025-003

WAGO: Vulnerability in WAGO Profinet IO Coupler 0750-0375

WAGO — 750 Fieldbus Coupler

WAGO PSIRTkritiek

Gepubliceerd

24 maart 2025

Laatste update

24 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The Fraunhofer Institute discovered a vulnerability in the Profinet IO Coupler 0750-0375 during fuzzing tests. These tests revealed weaknesses in the validation and processing of incoming data packets across various protocols and services.

Mitigatiesamenvatting

Update to firmware version 02.10.01 (12).

Revisiegeschiedenis (1)
  1. Initiële publicatie — 11 maart 2025

    Initial release.

Officiële bron: WAGO PSIRT

VDE-2024-053

Lenze: Install Directory with insufficient permissions

Lenze — EASY UI Designer

Lenze PSIRThoog

Gepubliceerd

3 september 2024

Laatste update

13 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The following tools: * VisiWinNET Smart * VisiWinNET Professional * EASY UI Designer create a directory with insufficient permissions, allowing a low-level user the ability to add and modify certain files that hold SYSTEM privileges, which could lead to privilege escalation.

Mitigatiesamenvatting

Only use this tool in a protected and controlled environment to minimize network impact and to ensure that the tool is inaccessable from outside. In addition, the use of firewalls is recommended to reduce the attack surface, specially to the internet and the internal business network.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 21 augustus 2024

    Initial revision.

  2. Update A — 6 november 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 13 maart 2025

    Fix: product version

Officiële bron: Lenze PSIRT

VDE-2025-036

Multiple vulnerabilities in Endress+Hauser MEAC300-FNADE4

Endress+Hauser — MEAC

Endress+Hauser PSIRThoog

Gepubliceerd

6 maart 2025

Laatste update

6 maart 2025

Getroffen sectoren

Risk evaluation

Several vulnerabilities in the Endress+Hauser MEAC300-FNADE4 were discovered, that can be accessed via Ethernet.

Mitigatiesamenvatting

Customers are strongly advised to update to the newest version.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 6 maart 2025

    Initial version

Officiële bron: Endress+Hauser PSIRT

VDE-2025-023

Weidmueller: OpenSSL vulnerability in industrial ethernet switches

Weidmüller — IE-SW

Weidmüller PSIRThoog

Gepubliceerd

5 maart 2025

Laatste update

5 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Multiple Weidmueller products are affected by an OpenSSL vulnerability. Weidmüller has released new firmwares of the affected products to fix the vulnerability.

Mitigatiesamenvatting

Update to version V3.6.30

Revisiegeschiedenis (2)
  1. Initiële publicatie — 5 maart 2025

    Initial version

  2. Update A — 5 maart 2025

    added categories to references

Officiële bron: Weidmüller PSIRT

VDE-2025-004

Vulnerability in libwagosnmp

WAGO — CC100

WAGO PSIRTmiddel

Gepubliceerd

5 maart 2025

Laatste update

5 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Nozomi Networks reported a vulnerability in the pfc firmware sdk-G2 of libwagosnmp. The WAGO pfc-firmware-sdk-G2 is a software development kit designed for WAGO PFC devices which developers to build and customize the firmware.

Mitigatiesamenvatting

Update to Firmware 04.07.01 (FW29) or Firmware 03.10.11 (FW22 Patch 2). For the latest Custom Firmware, please contact the WAGO support.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 5 maart 2025

    Initial release.

Officiële bron: WAGO PSIRT

VDE-2025-009

WAGO: Vulnerabilities in CODESYS Control V3 - OPC UA Stack

WAGO — CC100

WAGO PSIRThoog

Gepubliceerd

4 februari 2025

Laatste update

4 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Several WAGO Firmwares are vulnerable, due to an incorrect calculation of the buffer size in the CODESYS OPC UA STACK. This can lead to a crash of the runtime of the following firmware versions installed on several devices.

Mitigatiesamenvatting

The incorrect calculation of the buffer size can be avoided if the maximum supported array length of the OPC UA stack of the CODESYS Control runtime system is limited to a value of 10129639 (Stack.MaxArrayLenth=10129639) or less. This can be achieved by adding the following setting in the runtime configuration under the following path: /etc/codesys3.d/codesyscotrol.cfg

Revisiegeschiedenis (1)
  1. Initiële publicatie — 4 februari 2025

    Initial release.

Officiële bron: WAGO PSIRT

FSA-202406

Several Codesys Gateway v2 vulnerabilities in Codesys provided by Festo

Festo — CODESYS provided by Festo

Festo PSIRTkritiek

Gepubliceerd

3 december 2024

Laatste update

3 december 2024

Getroffen sectoren

Risk evaluation

An unauthenticated attacker would be able to send crafted requests to cause the CODESYS Gateway Server V2 to allocate excessive memory or consume all available TCP client connections. Besides, passwords are insufficiently checked during login. All versions of the following CODESYS V2 product prior version V2.3.9.38 are affected: • CODESYS Gateway Server

Mitigatiesamenvatting

Enable password protection at login in case no password is set at the controller. Please note that the password configuration file is not covered by the default FFT backup and restore mechanism. You must select the related file manually.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 3 december 2024

    Initial version

  2. Update A — 3 december 2024

    One reference has been corrected

Officiële bron: Festo PSIRT

VDE-2024-041

Endress+Hauser: Multiple products are vulnerable to code injection

Endress+Hauser — Echo Curve Viewer

Endress+Hauser PSIRTkritiek

Gepubliceerd

10 september 2024

Laatste update

10 september 2024

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Echo Curve Viewer is an utility used for offline visualization of previously recorded envelope curve data. Envelope curve records are exported from other Endress+Hauser software products like FieldCare as .curves files. Echo Curve Viewer opens .curves files and displays their contents. The .curves files contain device- specific C# calculation scripts as .cs files, that are needed for the interpretation of certain curve record types. Echo Curve Viewer loads .curves files and executes the contained C# code.

Mitigatiesamenvatting

- For standalone Echo Curve Viewer installations, download and install Echo Curve Viewer version >=6.00.00 from the Endress+Hauser Software Portal - For bundled installations with FieldCare SFE500, download and install FieldCare SFE500 Package version >= 1.40.1 from the Endress+Hauser Software Portal external link - For Field Xpert Devices, the required update is installed automatically during startup. This requires a working internet connection and (under certain circumstances) a valid maintenance period and/or a connection to the E+H Netilion Cloud. Please refer to the Field Xpert documentation for details regarding the update mechanism.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 10 september 2024

    Initial revision.

Officiële bron: Endress+Hauser PSIRT

VDE-2024-043

Welotec: Multiple products are vulnerable to regreSSHion

Welotec — EG500Mk2

Welotec PSIRThoog

Gepubliceerd

22 augustus 2024

Laatste update

22 augustus 2024

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Products from the Edge Gateway Family are affected by recently published so called RegreSSHion vulnerability.

Mitigatiesamenvatting

Disable SSH Access via CLI Command or Config Import locally or for a centrally managed device by changing the configuration in SMART EMSRefer to eG OS manual chapter 4.26 for further information

Revisiegeschiedenis (1)
  1. Initiële publicatie — 22 augustus 2024

    Initial revision.

Officiële bron: Welotec PSIRT

VDE-2024-032

Helmholz: REX 100 vulnerable to OS command injection

Helmholz — REX 100

Helmholz PSIRThoog

Gepubliceerd

3 juli 2024

Laatste update

3 juli 2024

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

There exists a vulnerability in all REX 100 devices with firmware <= 2.2.11 that allows an authenticated attacker to execute arbitrary system commands via GET requests. Update: 03.07.2024 3:30pm  In section Reported by Sebastian Dietz (CyberDanube) was added.

Mitigatiesamenvatting

As this is an authenticated exploit, you can mitigate it by making sure that no malicious actor can login to a vulnerable device.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 3 juli 2024

    Initial revision.

  2. Update A — 3 juli 2024

    In section Reported by Sebastian Dietz (CyberDanube) was added.

Officiële bron: Helmholz PSIRT

VDE-2024-030

MB connect line: mbNET.mini vulnerable to OS command injection

MB connect line — mbNET.mini

MB connect line PSIRThoog

Gepubliceerd

3 juli 2024

Laatste update

3 juli 2024

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

There exists a vulnerability in all mbNET.mini devices with firmware <= 2.2.11 that allows an authenticated attacker to execute arbitrary system commands via GET requests. Update: 03.07.2024 3:30 pm  In section Reported by Sebastian Dietz (CyberDanube) was added.

Mitigatiesamenvatting

As this is an authenticated exploit, you can mitigate it by making sure that no malicious actor can login to a vulnerable device.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 3 juli 2024

    Initial revision.

Officiële bron: MB connect line PSIRT

VDE-2024-023

Welotec: Clickjacking Vulnerability in WebUI

Welotec — SmartEMS

Welotec PSIRTmiddel

Gepubliceerd

23 april 2024

Laatste update

23 april 2024

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Welotec has been informed by an external source that the WebUI of the device management solution "SMART EMS" and the remote connectivity solution "VPN Security Suite" is vulnerable to so-called "Clickjacking" and advises to update to version v3.1.4 or later.

Mitigatiesamenvatting

This vulnerability can be mitigated with the use of an additional Reverse Proxy and / or Web Application Firewall protecting the WebUI.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 23 april 2024

    Initial revision.

Officiële bron: Welotec PSIRT

VDE-2024-002

Pilz: Multiple products affected by uC/HTTP vulnerability

Pilz — PIT gb RLLE y down ETH

Pilz PSIRTkritiek

Gepubliceerd

6 februari 2024

Laatste update

6 februari 2024

Getroffen sectoren

Risk evaluation

The PITreader product family is using the 3rd -party-component uC/HTTP to implement the web server functionality. uC/HTTP is affected by multiple vulnerabilities. These vulnerabilities may enable an attacker to gain full control over the system.

Mitigatiesamenvatting

Install the fixed firmware version. Please visit the Pilz Website to download the latest firmware update. Instructions about installing the firmware update can be found in the user manual. Limit network access to legitimate connections by using a firewall or similar measures.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 6 februari 2024

    Initial revision.

Officiële bron: Pilz PSIRT

VDE-2024-001

TRUMPF: Multiple products contain WIBU CodeMeter vulnerabilities

TRUMPF — MonitoringAnalyzer

TRUMPF PSIRTkritiek

Gepubliceerd

29 januari 2024

Laatste update

29 januari 2024

Getroffen sectoren

Risk evaluation

The TRUMPF CAD/CAM software tools mentioned above use the vulnerable CodeMeter Runtime (up to version 7.60d) application from WIBU-SYSTEMS AG to manage licenses within the component TRUMPF License Expert. This CodeMeter application contains new vulnerabilities, which may enable an attacker to gain full access to the server or workstation on which the TRUMPF License Expert has been installed on. A new version of the TRUMPF License Expert which fixes these vulnerabilities is available.

Mitigatiesamenvatting

CVE-2023-38545 only appears when used together with a SOCKS-5 Proxy. Not using theaffected products via a SOCKS-5 proxy mitigates the vulnerability.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 29 januari 2024

    Initial revision.

Officiële bron: TRUMPF PSIRT

VDE-2024-006

TRUMPF: Oseon contains vulnerable version of OpenSSL 1.1.x

TRUMPF — Oseon

TRUMPF PSIRTkritiek

Gepubliceerd

23 januari 2024

Laatste update

23 januari 2024

Getroffen sectoren

Risk evaluation

Multiple vulnerabilities in the included versions of OpenSSL can lead to different problems, including crashes of the OpenSSL modules (leading to a Denial of Service) or leakage of plaintext. These underlying vulnerabilities can be fixed by installing a software update provided by TRUMPF.

Mitigatiesamenvatting

Please contact your TRUMPF Service with the PR number 500876.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 23 januari 2024

    Initial revision.

Officiële bron: TRUMPF PSIRT

VDE-2023-059

Pilz: Electron Vulnerabilities in PASvisu and PMI v8xx

Pilz — PASvisu

Pilz PSIRThoog

Gepubliceerd

5 december 2023

Laatste update

5 december 2023

Getroffen sectoren

Risk evaluation

The Builder and Viewer components of the product PASvisu are based on the 3rd-party-component Electron. Electron contains several other open-source components which are affected by vulnerabilities. The vulnerabilities may enable an attacker to gain full control over the system. The vulnerabilities can be exploited locally or over the network.

Mitigatiesamenvatting

Install the fixed product version as soon as it is available. Please visit the Pilz eShop(https://www.pilz.com/en-INT/eshop) to check for the fixed version. Only use project files from trustworthy sources. Protect project files against modification by unauthorized users. Limit network access to legitimate connections by using a firewall or similar measures. Usepassword protection on the online project.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 5 december 2023

    Initial revision.

Officiële bron: Pilz PSIRT

VDE-2023-031

Trumpf: Multiple Products affected by WIBU Codemeter Vulnerability

TRUMPF — MonitoringAnalyzer

TRUMPF PSIRTkritiek

Gepubliceerd

13 september 2023

Laatste update

13 november 2023

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The TRUMPF CAD/CAM software tools mentioned above use the vulnerable CodeMeter Runtime (up to version 7.60b) application from WIBU-SYSTEMS AG to manage licenses within the component TRUMPF License Expert. This CodeMeter application contains new vulnerabilities, which may enable an attacker to gain full access to the server or workstation on which the TRUMPF License Expert has been installed on. A new version of the TRUMPF License Expert which fixes this vulnerability is available.Machines with a running and correctly installed mGuard hardware firewall cannot be exploited by this vulnerability if used as intended (according to the manual). Update A, 2023-11-13 Removed CVE-2023-4701 because it was revoked.

Mitigatiesamenvatting

Implement general security best practices like network segmentation, endpoint protection and system hardening. Restrict network access to the TRUMPF License Expert server component to required clients only by using firewalls or other suitable products.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 13 september 2023

    Initial revision.

  2. Update A — 13 november 2023

    Update A

Officiële bron: TRUMPF PSIRT