Direct naar inhoud
IACS RadarIndustrial Cyber Exposure & Intelligence

CISA + leveranciers

ICS Advisories

Advisories specifiek gericht op industriële besturingssystemen — van CISA ICS-CERT en rechtstreeks van leveranciers (onder meer Siemens, ABB, Schneider Electric, WAGO en Phoenix Contact) — inclusief revisiegeschiedenis (initiële publicatie, Update A, Update B) en gekoppelde CVE's.

493

Gevonden

Advisorydata: live koppeling— laatst opgehaald: 8 november 2026 om 04:44.

Filters

493 advisories gevonden

VDE-2023-043

Helmholz: Vulnerability allows access to non-critical information in myREX24 and myREX24.virtual

Helmholz — myREX24

Helmholz PSIRTmiddel

Gepubliceerd

16 oktober 2023

Laatste update

16 oktober 2023

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability in the affected products allows an authenticated, low-privileged attacker to gain unauthorized read access to limited, non-critical device information. The issue arises from improper access validation.

Mitigatiesamenvatting

Update to latest Version 2.14.3

Revisiegeschiedenis (1)
  1. Initiële publicatie — 16 oktober 2023

    Initial revision.

Officiële bron: Helmholz PSIRT

VDE-2022-056

Weidmueller: Multiple IoT and control products affected by JavaScript injection vulnerability

Weidmüller — 19 IOT MD01 LAN H4 S0011

Weidmüller PSIRTmiddel

Gepubliceerd

14 december 2022

Laatste update

14 december 2022

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A JavaScript injection vulnerability has been discovered in the XML editing system SCHEMA ST4 onlinehelp by Quanos Solutions GmbH. For details refer to CVE.This vulnerability may allow an attacker to inject JavaScript code via URL to the affected products

Mitigatiesamenvatting

If the remediation cannot be implemented in a timely manner, Weidmueller strongly recommends that the authenticated user logged in to the product does not click on links from external sources.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 14 december 2022

    Initial revision.

Officiële bron: Weidmüller PSIRT

VDE-2022-033

Pilz: PASvisu and PMI affected by multiple vulnerabilities

Pilz — PASvisu Software

Pilz PSIRThoog

Gepubliceerd

24 november 2022

Laatste update

24 november 2022

Getroffen sectoren

Risk evaluation

PASvisu is an HMI solution for Machine Visualization. It is available as a standalone software product, but it is also included in various models of the PMI product family. The PASvisu Server component contains multiple vulnerabilities which can be utilised to write arbitrary files, potentially leading to code execution.

Mitigatiesamenvatting

PASvisu software, PMI v7xx, PMI v8xx: Configure an administration password. PASvisu, PMI v7xx, PMI v8xx: Install the fixed version as soon as it is available. Please visit the Pilz Shop (www.pilz.com/enINT/eshop) to check for a fixed version.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 24 november 2022

    Initial revision.

Officiële bron: Pilz PSIRT

VDE-2022-043

Wiesemann & Theis: Multiple Vulnerabilities in the Com-Server Family

Wiesemann & Theis — AT-Modem-Emulator

Wiesemann & Theis PSIRTkritiek

Gepubliceerd

7 november 2022

Laatste update

7 november 2022

Getroffen sectoren

Risk evaluation

Multiple Wiesemann & Theis product families are affected by multiple vulnerabilities in the web interface.

Mitigatiesamenvatting

- Update Com-Server Family to version 1.48 or higher. - Update the Com-Server Highspeed Family to version 1.76 or higher.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 7 november 2022

    Initial revision.

Officiële bron: Wiesemann & Theis PSIRT

VDE-2022-023

TRUMPF TruTops prone to improper access control

TRUMPF — Job Order Interface

TRUMPF PSIRTkritiek

Gepubliceerd

17 oktober 2022

Laatste update

17 oktober 2022

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

During the installation of specific TRUMPF Windows applications, privileged local users with default usernames and passwords are created. An adversary could use these users to access and compromise the affected Windows systems and, under certain circumstances, other network resources.

Mitigatiesamenvatting

Please contact your TRUMPF Service with the PR number 496330.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 17 oktober 2022

    initial revision

Officiële bron: TRUMPF PSIRT

VDE-2022-034

TRUMPF: Products prone to Unified Automation vulnerabilities

TRUMPF — MOS

TRUMPF PSIRThoog

Gepubliceerd

15 augustus 2022

Laatste update

15 augustus 2022

Getroffen sectoren

Risk evaluation

A number of TRUMPF software tools use the OPC UA Server in C++ based OPC UA SDK by Unified Automation. The application contains several vulnerabilities, which enable an attacker to send malicious data to the application, resulting in a Denial-of-Service.

Mitigatiesamenvatting

Use the updated versions of the TRUMPF OPC UA server that will be available via MyTRUMPF.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 15 augustus 2022

    Initial revision.

Officiële bron: TRUMPF PSIRT

VDE-2022-030

Lenze: Vulnerability in the OPC-UA authentification connection in the firmware

Lenze — cabinet

Lenze PSIRTkritiek

Gepubliceerd

11 juli 2022

Laatste update

11 juli 2022

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The machine controller of the cabinet series include an OPC-UA server which uses an user management to authenticate clients via anonymous or user/password authentication. If the user/password authentication is selected, password verification is skipped upon second login. As a result, cases occur in which users can establish communication without correct authentication. This vulnerability is not located in the OPC-UA protocol or server, but in the interface to the products firmware. This Security Advisory is only relevant for the following use cases: • the user management has been activated on the machine controller (is deactivated by default) • the OPC-UA Server is used • Data are transferred via a symbol configuration (is not available by default)

Mitigatiesamenvatting

As part of a security strategy, Lenze SE recommends the following general defense measures to reduce the risk of exploits: • Only use the products in a protected and controlled environment to minimize network impact and to ensure that they are inaccessible from outside. • Use external firewalls to protect the automation system network and to separate it from other networks. Remark: One Measure should be to block port 4840 via the external firewall and open this port for authenticated access only. • Use Virtual Private Networks (VPN) tunnels when remote access is required. • Use IDS (Intrusion Detection Systems) where possible to detect anomalies in the network. • Activate and use user administration and password functions. • Use encrypted communication links. • Restrict access to both the development tools and their projects and the products of the automation system by physical means, operating system functions, etc. • Protect the development tool by using the latest virus detection solutions. • Use of certificate-based communication via the message security modes Sign or Sign&Encrypt and trust of the corresponding client certificates on the machine controller by the OPC-UA server. This can reduce the risk of exploiting this vulnerability.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 11 juli 2022

    Initial revision.

Officiële bron: Lenze PSIRT

VDE-2021-004

Weidmueller: EtherNet/IP Fieldbus Coupler out-of-bounds write

Weidmüller — UR20-FBC-EIP

Weidmüller PSIRThoog

Gepubliceerd

21 juni 2022

Laatste update

21 juni 2022

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A critical vulnerability has been discovered in the utilized component EtherNet/IP Adapter Development Kit (EADK) by Pyramid Solutions, Inc.. For details refer to CVE(s).This vulnerability may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition of the affected products. The indicated firmware versions are only used on products of hardware version 01.xx.xx.

Mitigatiesamenvatting

Weidmueller strongly recommends applying the following external protective measures: Restrict network access to the EtherNet/IP network containing affected products. If remote access is required, use secure methods such as virtual private networks (VPNs).

Revisiegeschiedenis (1)
  1. Initiële publicatie — 21 juni 2022

    Initial revision.

Officiële bron: Weidmüller PSIRT

VDE-2022-019

Endress+Hauser: Multiple products utilizing vulnerable WIBU-SYSTEMS CodeMeter components

Endress+Hauser — DeviceCare

Endress+Hauser PSIRTkritiek

Gepubliceerd

2 juni 2022

Laatste update

2 juni 2022

Getroffen sectoren

Risk evaluation

For detailed information please refer to WIBU SYSTEMS original Advisories at https://wibu.com/support/security-advisories.html.

Mitigatiesamenvatting

All vulnerabilities have already been fixed in several CodeMeter versions. Endress+Hauser recommends to use CodeMeter version >=7.40b. The version is available at https://www.wibu.com/support. For the Operating System WIN 7 it's recommended to update the operating system, use/re-install the Endress+Hauser Software Application supporting the newer operating system and update Code Meter to version >= 7.40b.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 2 juni 2022

    Initial revision.

Officiële bron: Endress+Hauser PSIRT

VDE-2022-016

TRUMPF: TruTops Fab, TruTops Boost prone to vulnerability

TRUMPF — TruTops Boost

TRUMPF PSIRTkritiek

Gepubliceerd

2 mei 2022

Laatste update

2 mei 2022

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A service function in the stated TRUMPF products is exposed without necessary authentication. Execution of this function may result in unauthorized access to, change of data or disruption of the whole service.

Mitigatiesamenvatting

Use the updated versions of the TRUMPF products that will be available via your service channel shortly or the hotfix, on following link: https://files.trumpf.com/w/LmhlkCA74heAIdS4GvJDDHqirMU0dpXbTRr7Erw8CXBvQ

Revisiegeschiedenis (1)
  1. Initiële publicatie — 2 mei 2022

    Initial revision.

Officiële bron: TRUMPF PSIRT

VDE-2021-061

Pilz: PMC programming tool 3.x.x affected by multiple vulnerabilities

Pilz — PMC programming tool 3.x.x

Pilz PSIRTkritiek

Risk evaluation

The software product PMC programming tool from Pilz is based on the software CODESYS Development System from CODESYS GmbH. This software is affected by several vulnerabilities, which an attacker can exploit locally or via the network. This means that, in a worst case, attackers could execute arbitrary program code on the PC on which the PMC programming tool is used.

Mitigatiesamenvatting

Use a hardware firewall, host-based firewall or comparable measures at network level toprotect against unauthorised network communication with the PC. Use a virus scanner or other measures to protect against malware. Only use CODESYS libraries and archives from trusted sources.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 26 april 2022

    Initial revision.

Officiële bron: Pilz PSIRT

VDE-2021-047

Bender/ebee: Multiple Charge Controller Vulnerabilities

Bender — CC612

Bender PSIRTkritiek

Gepubliceerd

26 april 2022

Laatste update

26 april 2022

Getroffen sectoren

Risk evaluation

Bender is publishing this advisory to inform customers about multiple security vulnerabilities in the Charge Controller product families.Bender has analysed the weaknesses and determined that the electrical safety of the devices is not concerned. To Benders knowledge, proof-of-concept code or exploits for the weaknesses are not available to the public.Bender considers some weaknesses to be critical and thus need to be patched immediately. Therefore, patches are provided as maintenance branch versions 5.11.2, 5.12.5, 5.13.2 and 5.20.2. Future software releases will of course already include these patches.

Mitigatiesamenvatting

Restrict network access to the above-mentioned devices.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 26 april 2022

    Initial revision.

Officiële bron: Bender PSIRT

VDE-2022-008

WEIDMUELLER: Multiple vulnerabilities in Modbus TCP/RTU Gateways

Weidmüller — IE-GW-MB-2TX-1RS232/485

Weidmüller PSIRTkritiek

Gepubliceerd

7 april 2022

Laatste update

7 april 2022

Getroffen sectoren

Risk evaluation

Multiple issues have been found in the affected products. See CVE descriptions for details.

Mitigatiesamenvatting

For all potential vulnerabilities, customers can download a patched firmware to secure their Modbus TCP/RTU Gateways properly. Please download and install the latest firmware for your device by following the procedure below: 1. Go to [www.weidmueller.com](https://www.weidmueller.com) (external link). 2. Enter the product number of the Modbus TCP/RTU Gateway you want to update into the search field and press "Enter". 3. On the next page, expand the drop-down menu **"SHOW DOWNLOADS"**. 4. Download the respective firmware from the download table. 5. Install the firmware on your device. Find below the appropriate patched firmware versions for all affected products: | Product number | Product name | Patched firmware version | |----------------|-------------------------------|------------------------------| | 1504460000 | IE-GW-MB-2TX-1RS232/485 | V2.1 (Build 21072817) | | 1504470000 | IE-GWT-MB-2TX-1RS232/485 | V2.1 (Build 21072817) |

Revisiegeschiedenis (1)
  1. Initiële publicatie — 7 april 2022

    Initial revision.

Officiële bron: Weidmüller PSIRT

VDE-2022-006

Endress+Hauser: FieldPort SFP50 Memory Corruption in Bluetooth Controller Firmware

Endress+Hauser — FieldPort SFP50 (mobiLink)

Endress+Hauser PSIRTmiddel

Gepubliceerd

24 maart 2022

Laatste update

24 maart 2022

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Possible memory corruption in BT controller when it receives an oversized LMP packet over 2-DH1 link and leads to denial of service.

Mitigatiesamenvatting

Endress+Hauser recommends using the FieldPort SFP50 only in secure environment and to allow access tothe devices only to authorized persons.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 24 maart 2022

    Initial revision.

Officiële bron: Endress+Hauser PSIRT

VDE-2021-048

Lenze: Multiple Vulnerabilities in CODESYS Control V2 communication

Lenze — Command Station CS

Lenze PSIRTkritiek

Gepubliceerd

4 oktober 2021

Laatste update

4 oktober 2021

Getroffen sectoren

Risk evaluation

The affected products contain a CODESYS Control runtime system in version V2. They are therefore affected by the vulnerability described in CODESYS Advisory 2021-06. It provides a communication server for the communication with clients like the CODESYS Development System. The 9400 servo inverters is only affected if the communication Path via the inserted EtherNet Module E94AYCEN on slot MXI1 or MXI2 is used. If the Module E94AYCEN is used, the following Versions are affected. Product Identification: E94xSHxxx (Single Drive, High Line) Product Identification: E94xMHxxx (Multi Drive, High Line) Remark: If the product identification of your 9400 product does not fit to the above mentioned identification, please contact Lenze at Security.de@Lenze.com. The Versions P (power supply module) and R (regenerative power supply module) are not affected. Furthermore, the Variant P (PLC) and the Variant S (StateLine) are not affected. The communication paths via the diagnostic interface X6, the system bus (CAN) X1 or the field buses (other than the named Ethernet module) that can be plugged into the module slots MXI1 or MXI2 are not affected. The focus is therefore on 9400 servo inverters with the product-identification E94x{S/M}{H}... with a plugged in Ethernet module E94AYCEN... in module slot MXI1 or MXI2 and communication with the Engineer-Tools via exactly this channel. In addition to the standard tool Engineer, there is also a special Version of the PLC Designer (Version 0.x). The communication path to the PLC Designer is not considered with the planned update and the vulnerabilities here remain even after the update. Here, the customer must provide a secure Environment, see Mitigation.

Mitigatiesamenvatting

As part of a security strategy, Lenze SE recommends the following general defense measures to reduce the risk of exploits: - Only use the products in a protected and controlled environment to minimize network impact and to ensure that they are inaccessible from outside. - Use firewalls to protect the automation system network and to separate it from other networks. Remark: One Measure should be to Block port 1200 via the firewall and open this port for authenticated access only. - Use Virtual Private Networks (VPN) tunnels when remote access is required. - Use IDS (Intrusion Detection Systems) where possible to detect anomalies in the network. - Activate and use user administration and password functions. - Use encrypted communication links. Restrict access to both the development tools and their projects and the products of the automation system by physical means, operating system functions, etc. - Protect the development tool by using the latest virus detection solutions.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 4 oktober 2021

    Initial revision.

Officiële bron: Lenze PSIRT

VDE-2021-033

TRUMPF Laser GmbH: multiple products prone to codesys runtime vulnerabilities

TRUMPF — TruControl in redpowerDirect

TRUMPF PSIRTkritiek

Gepubliceerd

12 augustus 2021

Laatste update

12 augustus 2021

Getroffen sectoren

Risk evaluation

The TruControl laser control software (versions 1.04 to 3.0.0) uses CODESYS runtime versions affected by multiple CVEs: **CVE list:** - CVE-2021-29242 - CVE-2021-29241 - CVE-2019-5105 - CVE-2020-7052 - CVE-2019-9012 - CVE-2019-9010 - CVE-2019-9009 - CVE-2018-10612 In addition to the CVEs listed above, the affected products are also vulnerable to the following issues without a CVE ID: --- ### **CODESYS Advisory 2018-07** A crafted communication request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition. - **CVSS v3.0 base score:** 6.5 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12928&token=6d1dcea05a15aeef7ad48eadc64c8eca5d4f07b2&download=) --- ### **CODESYS Advisory 2018-04** The CODESYS runtime system allows access to files outside the restricted working directory of the controller by online services. - **CVSS v3.0 base score:** 9.9 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12925&token=50e7240fa947ea215311e3db441f82152f1109b6&download=) --- ### **CODESYS Advisory 2017-03** A crafted request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition. - **CVSS v3.0 base score:** 7.5 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12912&token=2f23e7f047c2768dd06fdf072de49a7ba1fe9687&download=)

Mitigatiesamenvatting

- We highly recommend updating to TruControl version 3.16.0 or higher as soon as possible - Please contact your service partner (service.tls@trumpf.com) for immediate instructions on how to retrieve the update

Revisiegeschiedenis (1)
  1. Initiële publicatie — 12 augustus 2021

    initial revision

Officiële bron: TRUMPF PSIRT

VDE-2020-051

Beckhoff: DoS-Vulnerability for TwinCAT OPC UA Server and IPC Diagnostics UA Server

Beckhoff — IPC Diagnostics UA Server

Beckhoff PSIRTmiddel

Gepubliceerd

27 april 2021

Laatste update

11 mei 2021

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Some TwinCAT OPC UA Server and IPC Diagnostics UA Server versions from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of these requests the OPC UA server is no longer responsive to any client. This is without effect to the real-time functionality of IPCs. UPDATE A - 11.05.2021 Please note that some hardware products from Beckhoff are shipped with a TwinCAT OPC UA Server pre-installed. In some cases the server is enabled by default. IPC Diagnostics UA Server (contained in Beckhoff's Windows images) server versions up to and including 3.1.0.1 are affected Please note that IPC products from Beckhoff are shipped with an IPC Diagnostics UA Server pre-installed. In all cases the server is disabled by default. The version numbers named above always refer to the version number which is accessible via OPC UA at the server via the standard OPC UA node /Objects/Server/ServerStatus/BuildInfo/SoftwareVersion and on Windows also as the file property "File version" of the file TcOpcUaServer.exe for TwinCAT OPC UA Server respectively the file DevMgrSvr-UA.exe for IPC Diagnostics UA Server. UPDATE A - 11.05.2021 Please note that IPC products from Beckhoff are shipped with an IPC Diagnostics UA Server pre-installed. While on Windows CE it is disabled by default all other Windows images have it enabled by default.

Mitigatiesamenvatting

Consider disabling the IPC Diagnostics Server by stopping and disabling the corresponding Windows service or service. For example this can be achieved with the following PowerShell commands: Stop-Service -Force -Name DevMgrSvr-UA Set-Service -Name DevMgrSvr-UA -StartupType Disabled Alternatively consider limiting access to the TCP port the OPC UA server is listening on. This can happen with a dedicated firewall appliance which sits in front of an affected device. Alternatively at the device the Windows firewall can be configured to limit access to the TCP port. Further guidance is provided within the "Security Guide IPC" from Beckhoff which is accessible at https://www.beckhoff.com/secguide

Revisiegeschiedenis (2)
  1. Initiële publicatie — 27 april 2021

    Initial revision.

  2. Update A — 11 mei 2021

    UPDATE A

Officiële bron: Beckhoff PSIRT

VDE-2020-043

Bender: COMTRAXX < 4.2.0 affected by inadquate credentials check vulnerability

Bender — CP915

Bender PSIRTkritiek

Gepubliceerd

16 oktober 2020

Laatste update

16 oktober 2020

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Bender is publishing this advisory to inform customers about a security vulnerability in all devices running the COMTRAXX software. The user authorization is validated for most, but not all routes in the system. A user with knowledge about the routes can read and write configuration data without prior authorization.

Mitigatiesamenvatting

• restrict network access to the above-mentioned devices • install latest software update

Revisiegeschiedenis (1)
  1. Initiële publicatie — 16 oktober 2020

    Initial revision.

Officiële bron: Bender PSIRT