VDE-2020-009

WAGO: e!Cockpit Two Update Package Vulnerabilities

WAGO — PFC100

WAGO PSIRThoog

Gepubliceerd

9 maart 2020

Laatste update

22 mei 2025

Getroffen sectoren

Risk evaluation

The firmware update package (WUP) is not signed entirely. The used password offers no additional security, it is just meant to protect from unintentional modifications of the WUP file. Thus only the integrity of the signed firmware part (rauc file) is protected against intended manipulation. An attacker could manipulate the WUP file in a way that additional files with potentially malicious content are added to the WUP file. In case an authorized user that issues a firmware update could be tricked into installing this manipulated WUP file onto the device, the potentially malicious files would also be copied and installed on to the device and executed with elevated privileges.

Mitigatiesamenvatting

Execute FW-Update only as user 'admin'.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 9 maart 2020

    initial revision

  2. Update A — 22 mei 2025

    Fix: version space, quotation mark

Officiële bron: WAGO PSIRT

VDE-2020-011

WAGO: Multiple Vulnerabilities in I/O-Check Service

WAGO — PFC100

WAGO PSIRThoog

Gepubliceerd

9 maart 2020

Laatste update

22 mei 2025

Getroffen sectoren

Risk evaluation

An attacker needs an authorized login on the device in order to exploit the herein mentioned vulnerabilities. The reported vulnerabilities allow a local attacker with valid login credentials who is able to create files on the device to change the devices settings, e.g. default gateway address, time server etc. and potentially execute code.

Mitigatiesamenvatting

* Disable I/O-Check service. * Restrict network access to the device. * Do not directly connect the device to the internet. * Disable unused TCP/UDP-ports.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 9 maart 2020

    Initial revision.

  2. Update A — 22 mei 2025

    Fix: version space, quotation mark

Officiële bron: WAGO PSIRT

VDE-2021-014

WAGO: Multiple Vulnerabilities in CODESYS Runtime 2.3

WAGO — PFC200

WAGO PSIRTkritiek

Gepubliceerd

20 mei 2021

Laatste update

22 mei 2025

Getroffen sectoren

Risk evaluation

Multiple vulnerabilities were reported in CODESYS 2.3 Runtime. The CODESYS 2.3 Runtime is an essential component in several WAGO PLC's.

Mitigatiesamenvatting

If an immediate firmware update is not possible, the WLAN on the unit can also be switched off as a precautionary measure.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 15 mei 2021

    Initial revision.

  2. Update A — 22 mei 2025

    Fix: version space, added distribution, quotation mark

Officiële bron: WAGO PSIRT

VDE-2021-049

WAGO: Denial of Service Vulnerability in CODESYS Runtime 2.3

WAGO — PFC200

WAGO PSIRThoog

Gepubliceerd

16 november 2021

Laatste update

22 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A Denial-of-Service Vulnerability was reported in CODESYS 2.3 Runtime. The CODESYS 2.3 Runtime is an essential component in several WAGO PLC's. All vulnerable PLCs are listed in chapter 'Affected Products'.

Mitigatiesamenvatting

1. Use general security best practices to protect systems from local and network attacks. 2. Do not allow direct access to the device from untrusted networks. 3. Update to the latest firmware according to the table in chapter solutions. 4. Disable the CODESYS 2.3 port 2455.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 16 november 2021

    initial revision

  2. Update A — 22 mei 2025

    Fix: version space, added distribution, quotation mark

Officiële bron: WAGO PSIRT

VDE-2021-060

WAGO: Smart Script affected by Log4Shell Vulnerability

WAGO — Smart Script

WAGO PSIRTkritiek

Gepubliceerd

5 januari 2022

Laatste update

22 mei 2025

Getroffen sectoren

Risk evaluation

Apache Log4j is used for logging events in WAGO Smart Script in Version 4.2 and higher. Events logged by Log4j can contain JNDI references. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. Additionally, Log4j does not protect from self-referential lookups, which can lead to Denial of Service. UPDATE A1/2: Affected versions: CVE-2021-44228 and CVE-2021-45046: WAGO Smart Script >= Version 4.2 and < Version 4.8.1.3 CVE-2021-45105: WAGO Smart Script >= Version 4.2 and < Version 4.8.1.4 CVE-2021-44832 WAGO Smart Script >= Version 4.2 and < Version 4.8.1.5 END UPDATE A1/2

Mitigatiesamenvatting

Do not use projects from untrusted sources. For further impact information and risk mitigation, see the recommendations of the Apache Foundation https://logging.apache.org/log4j/2.x/security.html Bundesamt für Sicherheit in der Informationstechnik (BSI) https://www.bsi.bund.de/DE/Service-Navi/Presse/Pressemitteilungen/Presse2021/211211_log4Shell_WarnstufeRot.html

Revisiegeschiedenis (3)
  1. Initiële publicatie — 5 januari 2022

    Initial revision.

  2. Update A — 9 februari 2022

    Update

  3. Update B — 22 mei 2025

    Fix: added distribution, quotation mark

Officiële bron: WAGO PSIRT

VDE-2022-002

WAGO: Vulnerable WIBU-SYSTEMS Codemeter installed through e!COCKPIT and WAGO-I/O-Pro

WAGO — e!COCKPIT

WAGO PSIRThoog

Gepubliceerd

31 januari 2022

Laatste update

22 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

A vulnerability is reported in WIBU-SYSTEMS Codemeter. WIBU-SYSTEMS Codemeter is installed by default during e!COCKPIT and WAGO-I/O-Pro (CODESYS 2.3) installations. All currently existing e!COCKPIT installation bundles and WAGO-I/O-Pro (CODESYS 2.3) installation bundles are affected with vulnerable versions of WIBU-SYSTEMS Codemeter.

Mitigatiesamenvatting

Mitigation Use general security best practices to protect systems from local and network attacks. Disable the container type 'Mass Storage' in CodeMeter via the Windows Registry.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 31 januari 2022

    Initial revision.

  2. Update A — 22 mei 2025

    Fix: quotation mark

Officiële bron: WAGO PSIRT

VDE-2022-009

WAGO: Multiple Products affected by Linux Kernel Vulnerability Dirty Pipe

WAGO — PFC100

WAGO PSIRThoog

Gepubliceerd

6 april 2022

Laatste update

22 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The Linux kernel starting from 5.8 has a flaw which can lead to privilege escalation for a local user. The kernel is used in several Versions of the FW of several WAGO products. All vulnerable PLCs are listed in chapter 'Affected Products'.

Mitigatiesamenvatting

- Restrict network access to the device. - Use strong passwords - Do not directly connect the device to the internet - Disable unused TCP/UDP-ports

Revisiegeschiedenis (2)
  1. Initiële publicatie — 6 april 2022

    Initial revision.

  2. Update A — 22 mei 2025

    Fix: quotation mark

Officiële bron: WAGO PSIRT

VDE-2023-007

WAGO: Unauthenticated command execution via Web-based-management UPDATE A

WAGO — CC100

WAGO PSIRTkritiek

Gepubliceerd

15 mei 2023

Laatste update

22 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The 'legal information' plugin of web-based-management contained a vulnerability which allowed execution of arbitrary commands with privileges of www user. UPDATE A 15.06.2023 : Removed PFC100 with FW23 as affected product and from solution PFC200 with FW23 is only affected on 750-821x/xxx-xxx Renamed "FW22 Patch 1" to "FW22 SP1" to match the versions of the download portal

Mitigatiesamenvatting

As general security measures strongly WAGO recommends: Use general security best practices to protect systems from local and network attacks. Do not allow direct access to the device from untrusted networks. Update to the latest firmware according to the table in chapter solutions. Industrial control systems (ICS) should not be directly accessible from the Internet, but should be protected by consistently applying the defense-in-depth strategy. The BSI provides general information on securing ICS in the ICS Compendium (https://www.bsi.bund.de/SharedDocs/Downloads/EN/BSI/ICS/ICS-Security_compendium.pdf).

Revisiegeschiedenis (2)
  1. Initiële publicatie — 15 mei 2023

    Initial revision.

  2. Update A — 22 mei 2025

    Fix: quotation mark

Officiële bron: WAGO PSIRT

VDE-2023-026

WAGO: Multiple products prone to multiple vulnerabilities in e!Runtime / CODESYS V3 Runtime

WAGO — CC100

WAGO PSIRThoog

Risk evaluation

Multiple WAGO devices are prone to vulnerabilites in the used CODESYS V3 framework.

Mitigatiesamenvatting

Vulnerabilities of CODESYS Advisory 2023-02:• Please make sure that the 'port authentication' option in the web-based management is activated. In this way none of the vulnerabilities can be exploited by unauthenticated users.• Please change the default admin password. Vulnerability of CODESYS Advisory 2023-03:• This vulnerability exists in the CODESYS programming service which is needed for commission only. Deactivate the CODESYS programming port in the web-based management if you do not need the service. In addition to the mitigation hints CODESYS GmbH recommends the following general defense measures to reduce the risk of exploits: Use controllers and devices only in a protected environment to minimize network exposure and ensure they are not accessible from outside. Use firewalls to protect and separate the control system network from other networks. Use VPN (Virtual Private Networks) tunnels if remote access is required. Activate and apply user management and password features. Use encrypted communication links. Limit the access to both development and control system by physical means, operating system features, etc. Protect both development and control system by using up to date virus detection solutions. For further impact information and risk mitigation, please refer to the official CODESYS Advisory Website at https://www.codesys.com/security/security-reports.html

Revisiegeschiedenis (2)
  1. Initiële publicatie — 31 juli 2023

    Initial revision.

  2. Update A — 22 mei 2025

    Fix: quotation mark

Officiële bron: WAGO PSIRT

VDE-2024-047

WAGO: Multiple vulnerabilities in docker configuration

WAGO — CC100

WAGO PSIRThoog

Gepubliceerd

18 november 2024

Laatste update

22 mei 2025

Getroffen sectoren

Risk evaluation

Nozomi reported eight vulnerabilities to WAGO affecting different firmwares installed on several devices.

Mitigatiesamenvatting

Update to Firmware 4.6.1 (FW28) or for CC100 devices to 4.6.3 (FW28). For G1 devices update to Firmware 3.10.11 (FW22 Patch 2). For the latest Custom Firmware, please contact the WAGO support.

Revisiegeschiedenis (4)
  1. Initiële publicatie — 18 november 2024

    Initial document.

  2. Update A — 30 januari 2025

    Added known mitigations as remediation. Added the Custom Firmware to the product branch. Added firmware 3.10.11 (Firmware 22 Patch 2) to the fixed products. This version was in revision 1 listed as vulnerable.

  3. Update B — 12 februari 2025

    Fix: corrected self-reference, fixed version

  4. Update C — 22 mei 2025

    Fix: quotation mark

Officiële bron: WAGO PSIRT

VDE-2020-036

WAGO: Multiple Vulnerabilities in I/O-Check Service

WAGO — TP600

WAGO PSIRTkritiek

Gepubliceerd

29 juni 2021

Laatste update

14 mei 2025

Getroffen sectoren

Risk evaluation

Multiple vulnerabilities in the WAGO I/O-Check Service were reported.

Mitigatiesamenvatting

- Disable I/O-Check service - Restrict network access to the device. - Do not directly connect the device to the internet.

Revisiegeschiedenis (4)
  1. Initiële publicatie — 29 juni 2021

    Initial revision.

  2. Update A — 6 november 2024

    Fix: added self-reference

  3. Update B — 12 februari 2025

    Fix: corrected self-reference, fixed version

  4. Update C — 10 april 2025

    Fixed csaf publisher information

Officiële bron: WAGO PSIRT

VDE-2025-008

WAGO: Vulnerabilities in CODESYS Control

WAGO — CC100

WAGO PSIRThoog

Gepubliceerd

4 februari 2025

Laatste update

14 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The following firmware versions installed on several devices are are vulnerable due to a vulnerability in CODESYS Control.

Mitigatiesamenvatting

The vulnerability is only exploitable if the an attacker has successfully logged in with according user rights. To prevent attackers from exploiting the vulnerability it is recommend to change the standard password in the web based management.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 4 februari 2025

    Initial release.

  2. Update A — 19 februari 2025

    Update: fixed typo in Vendor fix, fixed version

  3. Update B — 14 mei 2025

    Fix: added distribution

Officiële bron: WAGO PSIRT

VDE-2020-004

WAGO: e!Cockpit cleartext communication and hardcoded key

WAGO — TP600

WAGO PSIRThoog

Gepubliceerd

9 maart 2020

Laatste update

14 mei 2025

Getroffen sectoren

Risk evaluation

The communication between e!Cockpit and the programmable logic controller is not encrypted. The broken cryptographic algorithm allows an attacker to decode the password for the e!Cockpit communication and with this to manipulate the application. The password used by e!Cockpit for authentication against the PLC is encrypted with a hard-coded key. An attacker is able to decrypt the password by listening to the network traffic.

Mitigatiesamenvatting

* Follow the instructions in WAGO's handbook Cyber Security for Controller * Restrict network access to the device. * Do not directly connect the device to the internet * Use an encrypted VPN connection to the device * Disable unused TCP/UDP-ports Typically the e!Cockpit communication is only needed during commissioning of the programmable logic controller and not during normal operations. WAGO highly recommends disabling the TCP Port 11740 and UDP Port 1740 after commissioning or using an encrypted VPN connection to the device.

Revisiegeschiedenis (3)
  1. Initiële publicatie — 9 maart 2020

    initial revision

  2. Update A — 10 april 2025

    Fixed namespace URL

  3. Update B — 14 mei 2025

    Fix: added distribution

Officiële bron: WAGO PSIRT

VDE-2020-028

WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Version <= FW03

WAGO — 750 Fieldbus Coupler

WAGO PSIRTkritiek

Gepubliceerd

30 september 2020

Laatste update

14 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The Web-Based Management (WBM) of WAGOs programmable logic controller (PLC) is typically used for administration, commissioning and updates. With special crafted requests it is possible to change some special parameters without authentication.

Mitigatiesamenvatting

* Restrict network access to the device. * Do not directly connect the device to the internet. * Disable unused TCP/UDP ports. * Disable web-based management ports 80/443 after the configuration phase

Revisiegeschiedenis (3)
  1. Initiële publicatie — 30 september 2020

    initial revision

  2. Update A — 10 april 2025

    Fixed csaf reference URL

  3. Update B — 14 mei 2025

    Fix: added distribution

Officiële bron: WAGO PSIRT

VDE-2020-029

WAGO: XSS vulnerability in Web-UI in WAGO 750-88X and WAGO 750-89X

WAGO — 750 Fieldbus Coupler

WAGO PSIRTmiddel

Gepubliceerd

30 september 2020

Laatste update

14 mei 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The Web-Based Management (WBM) of WAGOs programmable logic controller (PLC) is typically used for administration, commissioning and updates. The SNMP configuration page of the device is vulnerable for a persistent XSS (Cross-Site Scripting) attack.

Mitigatiesamenvatting

* Restrict network access to the device. * Use strong passwords * Do not directly connect the device to the internet * Disable unused TCP/UDP-ports

Revisiegeschiedenis (3)
  1. Initiële publicatie — 30 september 2020

    initial revision

  2. Update A — 10 april 2025

    Fixed csaf reference URL

  3. Update B — 14 mei 2025

    Fix: added distribution

Officiële bron: WAGO PSIRT

VDE-2025-003

WAGO: Vulnerability in WAGO Profinet IO Coupler 0750-0375

WAGO — 750 Fieldbus Coupler

WAGO PSIRTkritiek

Gepubliceerd

24 maart 2025

Laatste update

24 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

The Fraunhofer Institute discovered a vulnerability in the Profinet IO Coupler 0750-0375 during fuzzing tests. These tests revealed weaknesses in the validation and processing of incoming data packets across various protocols and services.

Mitigatiesamenvatting

Update to firmware version 02.10.01 (12).

Revisiegeschiedenis (1)
  1. Initiële publicatie — 11 maart 2025

    Initial release.

Officiële bron: WAGO PSIRT

VDE-2025-004

Vulnerability in libwagosnmp

WAGO — CC100

WAGO PSIRTmiddel

Gepubliceerd

5 maart 2025

Laatste update

5 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Nozomi Networks reported a vulnerability in the pfc firmware sdk-G2 of libwagosnmp. The WAGO pfc-firmware-sdk-G2 is a software development kit designed for WAGO PFC devices which developers to build and customize the firmware.

Mitigatiesamenvatting

Update to Firmware 04.07.01 (FW29) or Firmware 03.10.11 (FW22 Patch 2). For the latest Custom Firmware, please contact the WAGO support.

Revisiegeschiedenis (1)
  1. Initiële publicatie — 5 maart 2025

    Initial release.

Officiële bron: WAGO PSIRT

VDE-2025-009

WAGO: Vulnerabilities in CODESYS Control V3 - OPC UA Stack

WAGO — CC100

WAGO PSIRThoog

Gepubliceerd

4 februari 2025

Laatste update

4 maart 2025

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Several WAGO Firmwares are vulnerable, due to an incorrect calculation of the buffer size in the CODESYS OPC UA STACK. This can lead to a crash of the runtime of the following firmware versions installed on several devices.

Mitigatiesamenvatting

The incorrect calculation of the buffer size can be avoided if the maximum supported array length of the OPC UA stack of the CODESYS Control runtime system is limited to a value of 10129639 (Stack.MaxArrayLenth=10129639) or less. This can be achieved by adding the following setting in the runtime configuration under the following path: /etc/codesys3.d/codesyscotrol.cfg

Revisiegeschiedenis (1)
  1. Initiële publicatie — 4 februari 2025

    Initial release.