ICSA-26-209-04

Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP

Siemens — SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)

CISAkritiek

Risk evaluation

Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.6 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

Mitigatiesamenvatting

Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 28 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-019113 advisory

Officiële bron: CISA

ICSA-26-209-03

Siemens SIMATIC S7-PLCSIM Advanced

Siemens — SIMATIC S7-PLCSIM Advanced

CISAhoog

Gepubliceerd

14 juli 2026

Laatste update

28 juli 2026

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

SIMATIC S7-PLCSIM Advanced contains a vulnerability that could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

Mitigatiesamenvatting

Disable the S7-PLCSIM Virtual Switch binding on the network adapter used by the affected instance. This prevents the adapter from entering an external communication mode and removes the attack vector entirely. (see SIMATIC S7-PLCSIM Advanced Function Manual V8.0, 11/2025 Section 5.3 and Section 6.1.2.3; and SIMATIC S7-PLCSIM Advanced Function Manual API V8.0, 11/2025 Section 7.2)

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 28 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-828211 advisory

Officiële bron: CISA

ICSA-26-209-01

Siemens Desigo CC

Siemens — Desigo CC family V7

CISAkritiek

Gepubliceerd

14 juli 2026

Laatste update

28 juli 2026

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.

Mitigatiesamenvatting

Currently no fix is available

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 28 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-734552 advisory

Officiële bron: CISA

ICSA-26-202-06

Siemens CADRA

Siemens — CADRA

CISAkritiek

Risk evaluation

CADRA is affected by multiple zlib and Foxit vulnerabilities. Siemens has released a new version for CADRA and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

Mitigatiesamenvatting

Update to V2511 or later version

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 21 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-470355 advisory

Officiële bron: CISA

ICSA-26-202-05

Siemens IAM Client

Siemens — COMOS V10.4.5

CISAmiddel

Gepubliceerd

14 juli 2026

Laatste update

21 juli 2026

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Multiple Siemens products are affected by unquoted search path vulnerability in IAM Client. This could allow an authenticated local attacker to perform privilege escalation. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.

Mitigatiesamenvatting

Update to V10.6.1 or later version

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 21 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-288252 advisory

Officiële bron: CISA

ICSA-26-202-04

Siemens SIDIS Secured SmartPlug

Siemens — SIDIS Secured SmartPlug

CISAkritiek

Gepubliceerd

14 juli 2026

Laatste update

21 juli 2026

Getroffen sectoren

Risk evaluation

SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the latest version.

Mitigatiesamenvatting

Update to V7.26.0310 or later version

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 21 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-585531 advisory

Officiële bron: CISA

ICSA-26-202-03

Siemens Opcenter X

Siemens — Opcenter X

CISAkritiek

Gepubliceerd

14 juli 2026

Laatste update

21 juli 2026

Gekoppelde CVE's

Getroffen sectoren

Risk evaluation

Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X and recommends to update to the latest version.

Mitigatiesamenvatting

Update to V2604 or later version

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 21 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-096828 advisory

Officiële bron: CISA

ICSA-26-202-02

Siemens RUGGEDCOM APE1808 with Palo Alto Networks Virtual NGFW

Siemens — RUGGEDCOM APE1808

CISAhoog

Gepubliceerd

14 juli 2026

Laatste update

21 juli 2026

Getroffen sectoren

Risk evaluation

Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. [1] https://security.paloaltonetworks.com/

Mitigatiesamenvatting

Contact customer support to receive patch and update information

Revisiegeschiedenis (2)
  1. Initiële publicatie — 14 juli 2026

    Publication Date

  2. Update A — 21 juli 2026

    Initial CISA Republication of Siemens ProductCERT SSA-104023 advisory