VDE-2026-060
Phoenix Contact: Unauthenticated log download vulnerability in the firmware of CHARX SEC-3xxx charging controllers
Risk evaluation
VDE-2026-060: A unauthenticated log download vulnerability in the firmware of CHARX SEC-3xxx charging controllers has been discovered.
Mitigatiesamenvatting
Phoenix Contact strongly recommends to upgrade to firmware version 1.9.0 which fixes these vulnerabilities.
Revisiegeschiedenis (2)
Initiële publicatie — 3 juni 2026
Initial revision
Update A — 3 juni 2026
added "Firmware" to the textual description of the relationships.
Gepubliceerd
3 juni 2026
Laatste update
3 juni 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves the reported vulnerabilities. An attacker who successfully exploited any of these vulnerabilities could potentially compromise the system in different ways.
Mitigatiesamenvatting
ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience.
Revisiegeschiedenis (1)
Initiële publicatie — 3 juni 2026
Initial version.
VDE-2026-054
MB connect line: Multiple vulnerabilities in mbNET/mbNET.rokey/mbNET.mini
Gepubliceerd
27 mei 2026
Laatste update
27 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Two command injection vulnerabilities have been discovered in MB connect line mbNET/mbNET.rokey/mbNET.mini.
Mitigatiesamenvatting
Update: - mbNET/mbNET.rokey: 8.4.5 - mbNET.mini: 3.0.3
Revisiegeschiedenis (1)
Initiële publicatie — 27 mei 2026
Initial revision.
Gepubliceerd
27 mei 2026
Laatste update
27 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Two command injection vulnerabilities have been discovered in Helmholz REX100/REX200/REX250.
Mitigatiesamenvatting
Update: - REX200/250: 8.4.5 - REX100: 3.0.3
Revisiegeschiedenis (1)
Initiële publicatie — 27 mei 2026
Initial revision.
VDE-2026-050
Phoenix Contact: PLCnext Firmware Security Issues Related to APPs and Configuration Files
Gepubliceerd
27 mei 2026
Laatste update
27 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
This advisory addresses security issues in PLCnext firmware versions prior to 2026.0.3 that are related to APP handling and the processing of configuration files. The identified vulnerabilities affect APP installation authenticity as well as the handling of configuration data in writable directories. Successful exploitation may allow authenticated attackers with different privilege levels to compromise integrity, availability, and system security of affected PLCnext Control. Both issues are resolved starting with PLCnext firmware version 2026.0.3.
Mitigatiesamenvatting
For firmware versions prior to 2026.0.3 apps are installed via WBM (APP Manager) without enforced authenticity validation. Verify the SHA-256 checksum provided by the PLCnext Store manually before installing an APP. Restrict WBM access to trusted IP ranges via the firewall and protect Engineer credentials. Monitor APP lifecycle security notifications locally or via a central Syslog server. If APPs are not required, disable the APP Manager service via the WBM System Services page to eliminate an unnecessary attack vector. Starting with firmware version 2026.0.3, APP signature verification is enabled by default and only signed apps can be installed.
Revisiegeschiedenis (1)
Initiële publicatie — 27 mei 2026
Initial
Advisory2026-09_VDE-2026-055
CODESYS Development System - Incorrect Default Permissions
Gepubliceerd
26 mei 2026
Laatste update
26 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Two local privilege escalation vulnerabilities were identified in the CODESYS Development System. Specifically, the PackageManager and the IPM create temporary directories with insecure default permissions when executed with administrative privileges. This allows low-privileged local users to modify a temporary bootstrap file to force the deployment of arbitrary components, or to exploit a Time-of-Check to Time-of-Use (TOCTOU) race condition to replace digitally verified installation files with malicious ones prior to installation. Both flaws bypass intended security boundaries during the installation of packages or add-ons.
Mitigatiesamenvatting
Update the following product to version 3.5.22.20. * CODESYS Development System The CODESYS Development System and the products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/.
Revisiegeschiedenis (1)
Initiële publicatie — 26 mei 2026
Initial revision.
Risk evaluation
A vulnerability in the REST API of the JUMO device allows an attacker to trigger a denial‑of‑service (DoS) condition. Due to an incorrect implementation of the arrayLimit option in the Node.js qs module, limits for incoming request parameters are not properly enforced. As a result, an attacker can send specially crafted requests containing excessively large or deeply nested arrays, causing the web server to become unresponsive. This condition leads to a crash of the web server, followed by an automatic restart of the device.
Mitigatiesamenvatting
Update the affected products to version 431.10.0.0.26 for variTRON 300, to version 388.10.0.0.26 for variTRON 500 and to version 446.10.0.0.26 for variTRON 500 touch. The release of this versions are expected to Q2 2026.
Revisiegeschiedenis (1)
Initiële publicatie — 26 mei 2026
Release version.
SA25P006
PPT30 OPC-UA Server has issues handling concurrent connections
Risk evaluation
B&R is aware of a vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploits this vulnerability could make the OPC-UA server of the product inaccessible.
Mitigatiesamenvatting
The problem is corrected in the following product versions: PPT30 Operating System 1.8.0 The OPC-UA server is not activated by default. B&R recommends that customers with the OPC-UA Server enabled to install the update at their earliest opportunity. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revisiegeschiedenis (1)
Initiële publicatie — 26 mei 2026
Initial version.
Gepubliceerd
13 april 2026
Laatste update
22 mei 2026
Getroffen sectoren
Risk evaluation
Multiple vulnerabilities have been discovered in Helmholz myREX24V2/myREX24V2.virtual that could allow RCE, SQLi or information leakage.
Mitigatiesamenvatting
Update the myREX24V2/myREX24V2.virtual instance to version 2.19.5.
Revisiegeschiedenis (2)
Initiële publicatie — 13 april 2026
Initial revision.
Update A — 22 mei 2026
Typo Fix
Gepubliceerd
31 maart 2026
Laatste update
22 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
ABB is aware of public reports of vulnerabilities in 7-Zip version 18.5 and Microsoft Azure Data Studio version 1.32 included in the product versions listed as affected in the advisory. The vulnerability in 7-Zip can be exploited if attacker gains control over the system and extracts a malicious file using this version of 7-Zip. Otherwise, the attacker must force the user to visit malicious websites or click links and extract the package through 7-zip. Microsoft Azure Data Studio gets installed along with SQL Server Management Studio. An attacker who successfully exploits vulnerability in Microsoft Azure Data studio may compromise the security of the product by gaining privileges, reading sensitive information, executing commands, evading detection, etc. if the Authentication, Authorization and Accountability is not configured properly in the system. However, none of the products listed above uses Microsoft Azure Data Studio. Microsoft Azure Data Studio is automatically removed from the system from System 800xA 7.0 onwards. These vulnerabilities may appear when the product media is scanned. However, they can only be ex-ploited if the vulnerable software is installed on the system. For this reason, it is strongly advised to uninstall outdated or vulnerable versions of third-party software immediately.
Mitigatiesamenvatting
Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. There are no workarounds. Uninstalling the affected third-party software fully eliminates the risk of vulnerabilities. Refer to the section ‘Recommended immediate actions’.
Revisiegeschiedenis (2)
Initiële publicatie — 31 maart 2026
Initial version.
Update A — 22 mei 2026
Added missing CVE description for CVE-2024-26203.
Risk evaluation
ABB became aware of vulnerabilities in AC500 V2 listed as affected in the advisory. An attacker who successfully exploited this vulnerability could access fragments of Modbus telegrams that have been sent earlier by that PLC
Mitigatiesamenvatting
The vulnerabilities have been resolved in the following product versions: AC500 V2 firmware version 2.5.3 (released in 2016) and later
Revisiegeschiedenis (2)
Initiële publicatie — 23 juli 2025
Initial version.
Update A — 22 mei 2026
Minor correction to the affected product version in the product tree.
Advisory2026-07_VDE-2026-052
CODESYS Visualization - Insufficiently Protected Credentials
Risk evaluation
A vulnerability in the CODESYS Visualization login dialog has been identified. During logins within the CODESYS Visualization, authentication data may not be sufficiently isolated when multiple users perform login operations concurrently. As a result, an authenticated visualization user may be able to obtain credentials entered by another visualization user. The issue affects only login operations within an active visualization session and can be triggered via local and remote access to the visualization.
Mitigatiesamenvatting
Two alternative mitigation options have been identified. One option is to avoid using the Input Action "User Management -> Login" for changing users within an active visualization session. Instead, use the Input Action "User Management -> Logout" to do a complete logout followed by a new Login to the Visualization to re-login with another user. Alternatively, property handling within the visualization can be disabled via Project Settings -> Visualization -> General -> Advanced -> "Activate property handling in all element properties", if this is not required for the compilation of the application.
Revisiegeschiedenis (1)
Initiële publicatie — 21 mei 2026
Initial revision.
VDE-2024-017
Pepperl+Fuchs: ICE2- * and ICE3- * are affected by multiple vulnerabilities
Gepubliceerd
10 april 2024
Laatste update
18 mei 2026
Getroffen sectoren
Risk evaluation
Critical vulnerabilities have been discovered in the product due to outdated software components.The impact of the vulnerabilities on the affected device may result in Denial of service Bypassing of authentication Information disclosure
Mitigatiesamenvatting
External protective measures are required: Disable the webserver after configuration, if possible, by following these steps: - Enable SSH via the web server. - Login to the SSH server. - Disable the webserver via SSH portal. - Reboot the device. or: - Use HTTPS rather than HTTP while using the webserver. - Minimize network exposure for affected products and ensure that they are not accessible via the Internet. - Isolate affected products from the corporate network. - If remote access is required, use secure methods such as virtual private networks(VPNs). Pepperl+Fuchs will provide an update to address some of these vulnerabilities in the future.
Revisiegeschiedenis (3)
Initiële publicatie — 10 april 2024
Initial revision.
Update A — 22 mei 2025
Fix: quotation mark
Update B — 18 mei 2026
added score to vulnerability, Added CPEs, added last affected products to vulnerabilities
SA25P007
B&R Automation Studio Update of SQLite version
Gepubliceerd
18 februari 2026
Laatste update
14 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code execution.
Mitigatiesamenvatting
The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revisiegeschiedenis (2)
Initiële publicatie — 18 februari 2026
Initial version.
Update A — 14 mei 2026
Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.
SA26P001
PVI Insertion of Sensitive Information into Logfile
Risk evaluation
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. An attacker who successfully exploited this vulnerability could read sensitive information in the logging data of the PVI client application. Logging is deactivated by default in all PVI client versions.
Mitigatiesamenvatting
The problem is corrected in the following product versions: - PVI 6.5.0 Please note that PVI is included in the Automation Studio installation package and shares the same version number as the corresponding Automation Studio release. B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revisiegeschiedenis (2)
Initiële publicatie — 29 januari 2026
Initial version.
Update A — 14 mei 2026
Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.
Gepubliceerd
29 januari 2026
Laatste update
14 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. A network attacker could exploit the vulnerabilities to execute remote code, initiate DoS attacks, conduct DNS cache poisoning, or extract sensitive information.
Mitigatiesamenvatting
The problems are corrected in the following product versions: - APC4100 1.09 - APC910 No patch will be released (Please refer to the mitigation measures specified in this advisory). - C80 1.14 - MPC3100 1.24 - PPC1200 1.14 - PPC900 2.16 - APC2200 1.35 - PPC2200 1.35 - APC3100 1.45 - PPC3100 1.45 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revisiegeschiedenis (2)
Initiële publicatie — 29 januari 2026
Initial version.
Update A — 14 mei 2026
Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.
SA25P005
B&R Automation Runtime Improper Handling of Flooding conditions on ANSL Server
Gepubliceerd
19 januari 2026
Laatste update
14 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability. An attacker who successfully exploited this vulnerability could cause the product to stop.
Mitigatiesamenvatting
The problem is corrected in the following product versions: - Automation Runtime 6 versions >= 6.5 - Automation Runtime 4 versions >= R4.93 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revisiegeschiedenis (2)
Initiële publicatie — 19 januari 2026
Initial version.
Update A — 14 mei 2026
Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.
SA25P004
Automation Studio Insufficient Server Certificate Validation
Gepubliceerd
19 januari 2026
Laatste update
14 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that resolves a vulnerability. Successful exploitation of this vulnerability may enable an attacker to masquerade as a trusted party when B&R Automation Studio establishes a connection with a server via the ANSL over TLS or OPC-UA protocol.
Mitigatiesamenvatting
The problem is corrected in the following product versions: B&R Automation Studio version 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is de-scribed in the user manual.
Revisiegeschiedenis (2)
Initiële publicatie — 19 januari 2026
Initial Version
Update A — 14 mei 2026
Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.
SA25P003
B&R Automation Runtime Vulnerabilities in System Diagnostic Manager (SDM)
Gepubliceerd
7 oktober 2025
Laatste update
14 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Energieopwekking
Risk evaluation
An update is available that resolves a vulnerability identified by B&Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could take over a remote session or execute code in the context of the user’s browser session.
Mitigatiesamenvatting
The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revisiegeschiedenis (3)
Initiële publicatie — 7 oktober 2025
Initial version.
Update A — 14 oktober 2025
Added information about CVE-2025-11498.
Update B — 14 mei 2026
Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.
SA25P002
B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)
Risk evaluation
An update is available that resolves a vulnerability identified by B&Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited this vulnerability could cause the product to stop.
Mitigatiesamenvatting
The problem is corrected in Automation Runtime versions 6.3 and Q4.93. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not in-tended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&R recommends applying the update at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revisiegeschiedenis (2)
Initiële publicatie — 7 oktober 2025
Initial version.
Update A — 14 mei 2026
Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.
SCA-2025-0010
Multiple vulnerabilities in SICK Enterprise Analytics and SICK Logistic Analytics Products
Gepubliceerd
2 oktober 2025
Laatste update
13 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
SICK has found multiple vulnerabilities in SICK Enterprise Analytics and the SICK Logistic Analytics products. The vulnerabilities could potentially affect the confidentiality, integrity and availability of the products. Therefore it is strongly recommended to apply general security practices when operating the products. Currently, SICK is not aware of any public exploits.
Mitigatiesamenvatting
It is strongly recommended to update the product to version 4.6.3.
Revisiegeschiedenis (2)
Initiële publicatie — 2 oktober 2025
Initial version
Update A — 13 mei 2026
Fixes for the products Baggage Analytics, Package Analytics, Tire Analytics, Logistic Diagnostic Analytics.
Risk evaluation
Schneider Electric is aware of a vulnerability disclosed on Revenera FlexNet Publisher component. Many vendors, including Schneider Electric, embed Revenera FlexNet Publisher in their offers. Failure to apply the remediation/mitigations provided below may risk a local privilege escalation, which could lead to the execution of a malicious DLL with elevated privilege.
Mitigatiesamenvatting
Version 16.2 of EcoStruxure™ Control Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/ Reboot the computer after installation is completed.
Revisiegeschiedenis (4)
Initiële publicatie — 14 januari 2025
Original Release
Update A — 11 februari 2025
A remediation is available for the EcoStruxure™ Process Expert offer. The EcoStruxure™ Process Expert for AVEVA System Platform offer is added to the “Affected Product and Versions” section
Update B — 8 juli 2025
Pro-face BLUE is added to the “Affected Product and Versions” section. Remediations are now available for EcoStruxure™Control Expert, EcoStruxure™ Operator Terminal Expert and Pro-face BLUE offers. Updated the link to the fix of EcoStruxure™ Control Expert Asset Link offer
Update C — 14 oktober 2025
A remediation is now available for Zelio Soft 2 and EcoStruxure™ OPC UA Server Expert offers
SEVD-2025-042-03
EcoStruxure™ Process Expert, EcoStruxure™ Process Expert for AVEVA System Platform
Gepubliceerd
11 februari 2025
Laatste update
12 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Schneider Electric is aware of a vulnerability in its EcoStruxure™ Process Expert, EcoStruxure™ Process Expert for AVEVA System Platform products. The EcoStruxure™ Process Expert, EcoStruxure™ Process Expert for AVEVA System Platform products are engineering tools that facilitates and automates the design, maintenance, commissioning, and operation of Control projects for Modicon controllers and the associated Supervision projects for SCADA software regrouped in a system.. Failure to apply the Fix/Mitigations provided below may risk a local privilege escalation, which could result in loss of confidentiality, integrity and availability of the engineering workstation.
Mitigatiesamenvatting
Version v4.8.0.5715 of EcoStruxure™ Process Expert 2023 Software Package includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-processexpert/#software-and-firmware Uninstall Previous Version 2023 (v4.8.0.5115) before installing Version 2023 (v4.8.0.5715). Version string could be found on engineering server console.
Revisiegeschiedenis (2)
Initiële publicatie — 11 februari 2025
Original Release
Update A — 12 mei 2026
A remediation is available for EcoStruxure™ Process Expert for AVEVA System Platform
SEVD-2025-042-02
Improper Input Validation Vulnerability in Uni-Telway Driver
Gepubliceerd
11 februari 2025
Laatste update
12 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Schneider Electric is aware of a vulnerability in its [Uni-Telway driver](https://www.se.com/us/en/product-range/573-unitelway/#overview) which is part of [EcoStruxure™ Control Expert](https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#overview), [EcoStruxure™ Process Expert](https://www.se.com/ww/en/product-range/65406-ecostruxure-process-expert), [EcoStruxure™ Process Expert for AVEVA System Platform](https://www.se.com/ww/en/product-range/55570689-ecostruxure-process-expert-for-aveva-system-platform/#overview) and [OPC Factory Server](https://www.se.com/ww/en/product-range/547-opc-factory-server/) products. Failure to apply the mitigations provided below may risk denial of service of engineering workstation, which could result in interruption of engineering operation.
Mitigatiesamenvatting
For customers requiring the use of Uni-Telway driver, Schneider Electric recommends using following mitigations to reduce the risk of exploit:• McAfee Application and Change Control software for application control. Refer to the Cybersecurity Application Note available https://www.se.com/ww/en/download/document/EIO0000004778/ • Follow workstation, network and site-hardening guidelines in the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/ww/en/download/document/7EN52-0390/) document. For customers not requiring the use of Uni-Telway driver, Schneider Electric recommends uninstalling the driver. Version 16.2 of EcoStruxureTM Control Expert, version 2025 of EcoStruxureTM Process Expert, version 2025 of EcoStruxureTM Process Expert for AVEVA System Platform, and version 3.63SP3 of OPC Factory Server do not include Uni-Telway driver by default anymore. This vulnerability is only affecting customers who have installed Uni-Telway driver.
Revisiegeschiedenis (4)
Initiële publicatie — 11 februari 2025
Original Release
Update A — 8 juli 2025
Mitigations section updated for EcoStruxure™ Control Expert and OPC Factory Server.
Update B — 13 januari 2026
Mitigations are now available for EcoStruxure™ Process Expert. EcoStruxure™ Process Expert found to be not affected by this vulnerability and advisory title has been modified
Update C — 10 februari 2026
Removed comment “EcoStruxure™ Process Expert found to be not affected by this vulnerability.
SEVD-2026-013-02
Incorrect Default Permissions Vulnerability on EcoStruxure™ Process Expert
Gepubliceerd
13 januari 2026
Laatste update
12 mei 2026
Gekoppelde CVE's
Getroffen sectoren
Risk evaluation
Schneider Electric is aware of a vulnerability in its EcoStruxureTM Process and EcoStruxure™ Process Expert for AVEVA System Platform products. The EcoStruxureTM Process is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant. The EcoStruxure™ Process Expert for AVEVA System Platform product enables users to achieve operational profitability from design engineering to meeting the demands of modern-day production. It provides an asset centric and object-oriented automation platform to deploy system-wide standards in a digital ecosystem. Failure to apply the Fix/Mitigations provided below may risk modification of the executable binaries, which could result in privilege escalation.
Mitigatiesamenvatting
Version 2025 of EcoStruxure™ Process Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-process-expert
Revisiegeschiedenis (2)
Initiële publicatie — 13 januari 2026
Original Release
Update A — 12 mei 2026
A remediation is available for EcoStruxure™ Process Expert for AVEVA System Platform