Risk evaluation
A vulnerability in the REST API of the JUMO device allows an attacker to trigger a denial‑of‑service (DoS) condition. Due to an incorrect implementation of the arrayLimit option in the Node.js qs module, limits for incoming request parameters are not properly enforced. As a result, an attacker can send specially crafted requests containing excessively large or deeply nested arrays, causing the web server to become unresponsive. This condition leads to a crash of the web server, followed by an automatic restart of the device.
Mitigatiesamenvatting
Update the affected products to version 431.10.0.0.26 for variTRON 300, to version 388.10.0.0.26 for variTRON 500 and to version 446.10.0.0.26 for variTRON 500 touch. The release of this versions are expected to Q2 2026.
Revisiegeschiedenis (1)
Initiële publicatie — 26 mei 2026
Release version.