CISA + Hersteller
ICS-Advisories
Advisories speziell für industrielle Steuerungssysteme — von CISA ICS-CERT und direkt von Herstellern (darunter Siemens, ABB, Schneider Electric, WAGO und Phoenix Contact) — einschließlich Revisionshistorie (Erstveröffentlichung, Update A, Update B) und verknüpfter CVEs.
493
Gefunden
Advisory-Daten: Live-Anbindung— zuletzt abgerufen: 9. November 2026 um 11:56.
Filter
493 Advisories gefunden
Veröffentlicht
26. Januar 2026
Letzte Aktualisierung
12. Februar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
An optional package of the TwinCAT 3 XAR installs the TwinCAT 3 HMI Server on a device. It provides a server configuration page which can be accessed by administrative users only. When such an administrator accesses the server configuration page it is possible to upload arbitrary content into the CUSTOM_CSS field which is then persisted on the device and later returned and rendered with each login and error page. Please note that administrators have the access rights to modify any content on the HMI server, for example, via the server configuration page. Therefore, administrators would have to act maliciously to exploit this vulnerability.
Zusammenfassung der Gegenmaßnahmen
Please update to a recent version of the affected components.
Revisionshistorie (2)
Erstveröffentlichung — 10. Dezember 2025
Initial revision
Update A — 12. Februar 2026
A typo was corrected in the CVE description.
Veröffentlicht
9. Februar 2026
Letzte Aktualisierung
9. Februar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
Several vulnerabilities have been identified in the WAGO 852‑1328 device's web‑based management interface, which is implemented using a modified lighttpd server and custom CGI binaries. These issues include multiple stack buffer overflows, an authentication bypass, and insecure credential storage.
Zusammenfassung der Gegenmaßnahmen
Please update your devices to the specified fixed firmware version 02.65.
Revisionshistorie (1)
Erstveröffentlichung — 9. Februar 2026
Release version.
VDE-2021-011
TRUMPF Laser GmbH: TruControl 2.14.0 to 3.14.0 affected by recent sudo vulnerability
Veröffentlicht
22. März 2021
Letzte Aktualisierung
2. Februar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
TruControl laser control software from versions 2.14.0 to 3.14.0 use sudo versions affected by CVE-2021-3156. The affected sudo has a heap-based buffer overflow, allowing privilege escalation to root via "sudoedit -s" and a command-line argument that ends with a single backslash character.
Zusammenfassung der Gegenmaßnahmen
- Update to TruControl version 3.16.0 or higher or - Please contact your service partner (service.tls@trumpf.com) for instructions on how to retrieve the patch
Revisionshistorie (4)
Erstveröffentlichung — 22. März 2021
initial revision
Update A — 10. April 2025
Fixed csaf reference URL and publisher information.
Update B — 14. Mai 2025
Fix: added distribution
Update C — 2. Februar 2026
Fix: CSAF Document Alias had the wrong VDE-ID, changed revision versioning scheme to semver
PPSA-2026-001
Pilz: Multiple Vulnerabilities affecting the PIT User Authentication Service
Veröffentlicht
2. Februar 2026
Letzte Aktualisierung
2. Februar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
**PIT User Authentication Service is part of the operating mode selection and access permission system PITmode.** The PIT User Authentication Service is affected by multiple vulnerabilities in included third-party components.
Zusammenfassung der Gegenmaßnahmen
Limit network access to the PITreader and PIT User Authentication Service by using a firewall, a host-based firewall or similar measures.
Revisionshistorie (2)
Erstveröffentlichung — 2. Februar 2026
Initial Version
Update A — 2. Februar 2026
Summary has been updated.
Veröffentlicht
10. Juli 2023
Letzte Aktualisierung
2. Februar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
FactoryViews bundles many third-party applications which are used in background processes to provide the software's features. From time to time, vulnerabilities in these bundled applications are discovered. These are typically fixed in newer versions of FactoryViews by updating the bundled applications. FactoryViews versions up to and including 1.5.2 contain around 200 such vulnerabilities listed in this advisory.Version 1.6.0 is a security rollup release which includes updates to all bundled applications and fixes these vulnerabilities. At this time, FactoryViews Lite cannot be updated beyond version 1.1. FactoryViews 1.7 unifies the non-Lite and Lite versions and fixes these vulnerabilities for users of FactoryViews Lite.
Zusammenfassung der Gegenmaßnahmen
FactoryViews (non-Lite): Upgrade to FactoryViews 1.6.0. See the upgrade guide for information on how to upgrade. FactoryViews Lite: Upgrade to FactoryViews 1.7.0. See the upgrade guide for information on how to upgrade.
Revisionshistorie (4)
Erstveröffentlichung — 10. Juli 2023
Initial revision.
Update A — 11. Januar 2024
Adjust link to VDE Advisory.
Update B — 31. Juli 2025
Adjusted to VDE template. Changed title from "Several Vulnerabilities in FactoryViews <= 1.5.2" to "Festo: Several vulnerabilities in FactoryViews". Updated legal disclaimer to add references to special provisions. Included remediation for FactoryViews Lite
Update C — 2. Februar 2026
Added missing CWE values
VDE-2025-092
Beckhoff: Privilege escalation and information leak via Beckhoff Device Manager
Veröffentlicht
27. Januar 2026
Letzte Aktualisierung
27. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
The vulnerability CVE-2025-41726 (NN-2025-0074) allows an authenticated remote user to execute arbitrary commands on the device. This can be exploited over the web UI or via API. In one case the execution of the arbitrary command happens within a privileged process. The vulnerability CVE-2025-41727 (NN-2025-0075) allows a local user with low privileges on the device to bypass the authentication mechanism of the UI and send commands to a privileged process which it executes on behalf of that user but with higher privileges. This way the local user can escalate privileges. The vulnerability CVE-2025-41728 (NN-2025-0076) allows an authenticated remote user to cause an out-of-bounds read operation within a specific service process which runs on the device. The read operation might copy sensitive information from the memory of the specific service into a response message which is then provided to the user but the user cannot choose which information is disclosed.
Zusammenfassung der Gegenmaßnahmen
Please update to a recent version of the affected components or update the complete operating system image. Operating system images are available on request from Beckhoff's service (service@beckhoff.com). The setup / installer for Windows 10 and 11 are available on request from Beckhoff's service also.
Revisionshistorie (2)
Erstveröffentlichung — 20. Januar 2026
Initial revision
Update A — 27. Januar 2026
fixed date
Veröffentlicht
26. Januar 2026
Letzte Aktualisierung
26. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
SICK has identified a 3rd party vulnerability (CVE-2025-55093) in the nanoScan3 and microScan3. Only specific variants within the microScan3 and nanoScan3 families are affected by CVE-2025-55093. The underlying issue in the NetX Duo networking module could, under specific conditions, cause the device to enter a safe error state that requires a restart. SICK recommends applying the mitigation for CVE-2025-55093.
Zusammenfassung der Gegenmaßnahmen
Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.
Revisionshistorie (1)
Erstveröffentlichung — 26. Januar 2026
Initial version
Veröffentlicht
15. Januar 2026
Letzte Aktualisierung
22. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
SICK has identified multiple vulnerabilities in the SICK Incoming Goods Suite product. Vulnerabilities related to Grafana apply exclusively to the administrative user interface for log management and do not affect the Incoming Goods Suite user interface. The vulnerabilities could potentially affect the confidentiality, integrity an availability of the product. Therefore it is strongly recommended to apply general security practices when operating the product.
Zusammenfassung der Gegenmaßnahmen
Users are strongly recommended to upgrade to the latest release of Incoming Goods Suite (>= 1.2.1).
Revisionshistorie (2)
Erstveröffentlichung — 15. Januar 2026
Initial version
Update A — 22. Januar 2026
Corrected CVE IDs
VDE-2025-095
WAGO: Vulnerabilities in WAGO Industrial-Managed Switches
Veröffentlicht
10. Dezember 2025
Letzte Aktualisierung
19. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
Two remote stack buffer overflow vulnerabilities were discovered in WAGO industrial switches. These issues originate from unsafe input handling in custom HTTP request parsing functions within the lighttpd binary. The affected binary lacks modern security features such as PIE and RELRO, increasing the risk of successful exploitation.
Zusammenfassung der Gegenmaßnahmen
Please update your devices to the specified fixed firmware version.
Revisionshistorie (3)
Erstveröffentlichung — 10. Dezember 2025
Initial release.
Update A — 11. Dezember 2025
Updated CVSS-Scores
Update B — 19. Januar 2026
Updated model numbers.
Veröffentlicht
15. Januar 2026
Letzte Aktualisierung
15. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
SICK has identified multiple vulnerabilities in the SICK TDC-X401GL product. The vulnerabilities could potentially affect the confidentiality, integrity an availability of the product. Therefore it is strongly recommended to apply general security practices when operating the product. SICK is currently not aware of any public exploits.
Zusammenfassung der Gegenmaßnahmen
Users are strongly recommended to upgrade to the latest release of TDC-X401GL (>= 1.4.0).
Revisionshistorie (2)
Erstveröffentlichung — 15. Januar 2026
Initial version
Update A — 12. Mai 2026
Updated CVE Record
Veröffentlicht
9. Juli 2024
Letzte Aktualisierung
15. Januar 2026
Betroffene Sektoren
Risk Evaluation
In ifm Smart PLC firmware up to version 4.3.17 for Smart PLC controllers AC14xx and AC4xxS, an attacker can access the configuration by using the hardcoded credentials. The endpoint hosts a scripts capable of executing various commands.
Zusammenfassung der Gegenmaßnahmen
When using automation components, make sure that no unauthorized access can take place. Addition measures should be taken to ensure that the components do not have direct access to Internet resources and that they cannot be accessed from insecure networks. Use available security measures such as authentication and authorization groups.
Revisionshistorie (4)
Erstveröffentlichung — 9. Juli 2024
Initial revision.
Update A — 27. August 2025
Update: CWE from CVE-2024-28751, Revision History
Update B — 6. Januar 2026
Fixed Version range, Added Score to Vulnerability CVE-2024-28750, deleted "firmware" from the full product name of the hardware, changed Vulnerability title to CVE description
Update C — 15. Januar 2026
Update Product information
Veröffentlicht
6. Mai 2024
Letzte Aktualisierung
15. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
moneo \"Forgot Password\" function has a vulnerability which allows gaining privileged access.
Zusammenfassung der Gegenmaßnahmen
Update to moneo version 1.13.5 or later.
Revisionshistorie (4)
Erstveröffentlichung — 6. Mai 2024
initial revision
Update A — 24. Mai 2024
final draft
Update B — 27. Mai 2024
Update
Update C — 3. Juni 2024
Update after review
VDE-2025-073
Phoenix Contact: Security Advisory for TC ROUTER and CLOUD CLIENT Industrial mobile network routers
Veröffentlicht
13. Januar 2026
Letzte Aktualisierung
13. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
A code injection vulnerability at the upload-config endpoint in the firmware of TC ROUTER and CLOUD CLIENT Industrial Mobile network routers has been discovered that can be exploited by an high privileged attacker.
Zusammenfassung der Gegenmaßnahmen
As this vulnerability can only be exploited by an authenticated high privileged user, Phoenix Contact recommends to strictly restrict administrative access to the device. The administrative use shall only import configuration files from trusted sources.
Revisionshistorie (1)
Erstveröffentlichung — 13. Januar 2026
Initial Revision
VDE-2025-071
Phoenix Contact: Multiple Vulnerabilities in FL SWITCH 2xxx Firmware
Veröffentlicht
9. Dezember 2025
Letzte Aktualisierung
12. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
Multiple vulnerabilities have been identified in the FL SWITCH 2xxx firmware prior to version 3.50. Two of these (CVE-2025-41692 and CVE-2025-41696) enable an attacker to access the device's file system. Two other vulnerabilities (CVE-2025-41693 and CVE-2025-41694) are related to Denial of Service (DoS) attacks, which partly limit the device's functionality. Another vulnerability (CVE-2025-41697) allows an unauthenticated physical attacker to access a login shell via an undocumented UART port. Furthermore, there are multiple vulnerabilities relating to reflected cross-site scripting in the web-based management of the device. All vulnerabilities have been resolved in firmware version 3.50.
Zusammenfassung der Gegenmaßnahmen
Phoenix Contact strongly recommends to upgrade to firmware 3.50 which addresses this vulnerability and is available for download for all affected devices.
Revisionshistorie (2)
Erstveröffentlichung — 9. Dezember 2025
Initial release.
Update A — 12. Januar 2026
Version range specifier and product idfentification helper added to firmware branch of product tree.
Veröffentlicht
12. Dezember 2022
Letzte Aktualisierung
6. Januar 2026
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
An unauthenticated remote attacker could reset the administrator's password with information from the default, self-signed certificate.
Zusammenfassung der Gegenmaßnahmen
The certificate is renewed by adjusting the hostname to an own customer-specific, so it does not contain the serial number.
Revisionshistorie (2)
Erstveröffentlichung — 12. Dezember 2022
Initial revision.
Update A — 6. Januar 2026
fixed version range, added Hardware with relationship, changed vulnerability title to CVE description
VDE-2025-105
Endress+Hauser: Multiple products affected by Wibu-Systems CodeMeter Vulnerability
Veröffentlicht
8. Dezember 2025
Letzte Aktualisierung
8. Dezember 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
A vulnerability in Wibu-Systems CodeMeter (up to version 7.60b) affects multiple Endress+Hauser products. This flaw can lead to a heap buffer overflow, which may allow remote code execution under certain conditions.
Zusammenfassung der Gegenmaßnahmen
If possible, configure CodeMeter to run in client-only mode. If server mode is required, restrict access to authorized clients by implementing an access control list. For Proline Promag 800 OPC UA Connectivity, CodeMeter operates as a server only during license activation. Installation and license activation are managed by Endress+Hauser. If a customer performs manual license activation, it is strongly recommended to limit network access to necessary clients only by using firewalls or equivalent security measures.
Revisionshistorie (1)
Erstveröffentlichung — 8. Dezember 2025
Initial version
Veröffentlicht
27. Februar 2024
Letzte Aktualisierung
8. Dezember 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
MES PCs shipped with Windows 10 come pre-installed with XAMPP. XAMPP is a bundle of third-party open-source applications including the Apache HTTP Server, the MariaDB database and more. From time to time, vulnerabilities in these applications are discovered. These are fixed in newer versions of XAMPP by updating the bundled applications. MES PCs shipped with Windows 10 include a copy of XAMPP which contains around 140 such vulnerabilities listed in this advisory. They can be fixed by replacing XAMPP with Festo Didactic's Factory Control Panel application.
Zusammenfassung der Gegenmaßnahmen
Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.
Revisionshistorie (3)
Erstveröffentlichung — 27. Februar 2024
Initial version
Update A — 4. November 2025
Adjust to VDE template. Add missing CWE-IDs if available. Updated legal disclaimer to add references to special provisions.
Update B — 8. Dezember 2025
Add all missing CWE identifier and CVSS 3.x scores.
Advisory2025-11_VDE-2025-101
CODESYS Development System - Deserialization of Untrusted Data
Veröffentlicht
1. Dezember 2025
Letzte Aktualisierung
1. Dezember 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
A vulnerability has been discovered in the print engine of the CODESYS development system. If a CODESYS project file or archive file was crafted in a specific way, the CODESYS development system could execute arbitrary code when a user opens these files and configures the print/printer options or prints the project or parts of it. This arbitrary code would be executed in the context of the user who was tricked into opening the project.
Zusammenfassung der Gegenmaßnahmen
Open/install CODESYS archives, projects and packages from trustworthy sources only.
Revisionshistorie (1)
Erstveröffentlichung — 1. Dezember 2025
Initial revision.
VDE-2025-094
Janitza: Vulnerability in Modbus interface of UMG 96-PA and UMG 96-PA-MID+
Veröffentlicht
24. November 2025
Letzte Aktualisierung
24. November 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
A vulnerability in the devices UMG 96-PA and UMG 96-PA-MID+ enables an unauthenticated remote attacker to cause the device to become unavailable.
Zusammenfassung der Gegenmaßnahmen
It is strongly advised to operate the device in a closed network protected by a suitable firewall. Network access to the device should be limited to only enable necessary components to access it. Special focus should be on the Modbus protocol as the core communication protocol of the device.
Revisionshistorie (1)
Erstveröffentlichung — 24. November 2025
Initial release.
Veröffentlicht
16. Juni 2025
Letzte Aktualisierung
21. November 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
Vulnerabilities have been discovered in the WAGO Device Manager that allow any origin to access the server and set header values, as well as an endpoint that permits read access to the file system. The WAGO Device Manager is a software for configuring and parameterizing single WAGO products, which is included in the firmware. These vulnerabilities could be exploited by attackers to send requests and read server responses through crafted web applications or to access the file system.
Zusammenfassung der Gegenmaßnahmen
Update to Firmware version 04.07.01 (FW29) or 03.10.11 (FW22 Patch 2). For the latest Custom Firmware please contact the WAGO support.
Revisionshistorie (4)
Erstveröffentlichung — 16. Juni 2025
Initial release.
Update A — 4. Juli 2025
Removed incorrect custom firmware versions.
Update B — 7. Oktober 2025
Fixed a typo in the description for CVE-2025-25264
Update C — 21. November 2025
The two CVE descriptions and CVSS scores were edited.
Veröffentlicht
27. Oktober 2025
Letzte Aktualisierung
11. November 2025
Betroffene Sektoren
Risk Evaluation
SICK has identified multiple vulnerabilities in the SICK TLOC100-100 product. The vulnerabilities could potentially affect the confidentiality, integrity an availability of the product. Therefore it is strongly recommended to apply general security practices when operating the product. SICK is currently not aware of any public exploits.
Zusammenfassung der Gegenmaßnahmen
Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources "SICK Operating Guidelines" and "ICS-CERT recommended practices on Industrial Security" could help to implement the general security practices.
Revisionshistorie (2)
Erstveröffentlichung — 27. Oktober 2025
Initial version
Update A — 11. November 2025
Removed CVE ID
Veröffentlicht
10. November 2025
Letzte Aktualisierung
10. November 2025
Verknüpfte CVEs
Betroffene Sektoren
Energieopwekking
Risk Evaluation
A vulnerability was identified in the variTRON password generation algorithm of the debug-interface. The PRNG is initialized with the current Unix Timestamp, thus the resulting password is predictable. With the password root-access to the UART and ssh Interface can be gained. The impact is limited, since the debug-interface has to be actively enabled by an authorized user and will be deactivated automatically after the next reboot of the device.
Zusammenfassung der Gegenmaßnahmen
Update the affected products to version 9.0.2.5.
Revisionshistorie (1)
Erstveröffentlichung — 10. November 2025
Release version.
FSA-202405
Festo: Siemens S7-1500/ET200SP CPU used in Festo Didactic products contains a memory protection bypass vulnerability
Veröffentlicht
9. September 2024
Letzte Aktualisierung
5. November 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
Siemens SIMATIC S7-1200 and S7-1500 CPUs contained in various Festo Didactic products contain a memory protection bypass vulnerability that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks
Zusammenfassung der Gegenmaßnahmen
Update Siemens Simatic S7-1500 / ET200SP Firmware to V2.9.2 or higher
Revisionshistorie (4)
Erstveröffentlichung — 9. September 2024
Initial version
Update A — 6. November 2024
Fix: correct certvde domain, fixed language setting, added self-reference
Update B — 27. Februar 2025
Update: new Dokument ID
Update C — 5. November 2025
Removed environmental score from CVSS rating.
Veröffentlicht
30. Januar 2024
Letzte Aktualisierung
4. November 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
Several high severity vulnerabilities in CODESYS V3 affecting Festo products could lead to Remote Code Execution or Denial of Service.
Zusammenfassung der Gegenmaßnahmen
As part of a security strategy, Festo recommends the following general defense measures to reduce the risk of exploits: - Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside - Use firewalls to protect and separate the control system network from other networks - Use VPN (Virtual Private Networks) tunnels if remote access is required Activate and apply user management and password features - Use encrypted communication links - Limit the access to both development and control system by physical means, operating system features, etc. - Protect both development and control system by using up to date virus detecting solutions Festo strongly recommends to minimize and protect network access to connected devices with state of the art techniques and processes. For a secure operation follow the recommendations in the product manuals.
Revisionshistorie (2)
Erstveröffentlichung — 30. Januar 2024
Initial revision.
Update A — 4. November 2025
Adjusted to VDE template. Changed title from "Several Codesys Vulnerabilities in Festo Products" to "Festo: Multiple products contain CoDe16 vulnerability". Updated legal disclaimer to add references to special provisions.
Veröffentlicht
3. November 2025
Letzte Aktualisierung
3. November 2025
Verknüpfte CVEs
Betroffene Sektoren
Risk Evaluation
Several WAGO firmwares installed on different devices are impacted by various CODESYS vulnerabilities. These affect the runtime, visualization, and OPC UA server.
Zusammenfassung der Gegenmaßnahmen
Update to Firmware version 04.08.01 (FW30), 01.05.01 (FW05), 03.10.11 (FW22 Patch 2). For the latest Custom Firmware please contact the WAGO support.
Revisionshistorie (1)
Erstveröffentlichung — 3. November 2025
Release version.