Advisory2025-08_VDE-2025-070

CODESYS Control V3 - NULL pointer dereference

CODESYS — CODESYS Control RTE (SL)

CODESYS PSIRThigh

Published

4 August 2025

Last update

14 October 2025

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in the CODESYS Control runtime system's CmpDevice component allows unauthenticated attackers to cause a denial-of-service (DoS) via specially crafted communication requests. The issue is triggered by a NULL pointer dereference and also affects systems when outdated CODESYS clients attempt to log in. Only PLCs based on the CODESYS Runtime Toolkit containing the components CmpDevice, CmpAuditLog, and CmpSessionInformation are impacted. **Update 1.1.0, 01.09.2025:** Updated remediation category - fixed SL runtimes are now available.

Mitigation summary

The vulnerability can be mitigated by restricting the allowed login authentication type "CmpUserMgr/UserLogin_AuthenticationType" to "ONLY_ASYMMETRIC". This can be configured either via the Device Security Settings dialog in the CODESYS Development System or directly in the configuration file of the CODESYS Control runtime system (CODESYSControl.cfg) by adding the following setting: [CmpUserMgr] SECURITY.UserLogin_AuthenticationType=ONLY_ASYMMETRIC With this configuration in place, both potential attackers and legacy CODESYS protocol clients (prior to version 3.5.16.0) will be blocked from logging in, thereby preventing execution of the vulnerable code path.

Revision history (3)
  1. Initial publication — 4 August 2025

    Initial revision.

  2. Update A — 1 September 2025

    Updated remediation category - fixed SL runtimes are now available.

  3. Update B — 14 October 2025

    List of affected and fixed products corrected regarding CODESYS HMI (SL) and CODESYS Runtime Toolkit

Official source: CODESYS PSIRT

FSA-202206

Festo: Vulnerable WIBU-SYSTEMS CodeMeter Runtime in multiple products

Festo — CIROS

Festo PSIRThigh

Published

13 December 2022

Last update

1 October 2025

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability was reported in WIBU-SYSTEMS CodeMeter Runtime. WIBU-SYSTEMS CodeMeter Runtime is part of the installation packages of several Festo products.FluidDraw < 6.2c and CIROS <= 7.0.6 contain a vulnerable version of WIBU-SYSTEMS CodeMeter Runtime.

Mitigation summary

FluidDraw P5, FluidDraw P6 Avoid any FluidDraw installation with a FluidDraw installation package below version 6.2c. Updated versions of FluidDraw are available on the Festo website. In case of a FluidDraw installation package with a version below 6.2c, do not use the WIBU CodeMeter package, that is part of the FluidDraw installation package. Skip the CodeMeter installation step during the FluidDraw installation and instead use a current CodeMeter version from the WIBU website and install that separately. In case of an already installed vulnerable CodeMeter version, update all of these WIBU CodeMeter installations with the current version of WIBU CodeMeter. Please refer to the WIBU CodeMeter documentation and website for further details and mitigations on usage of WIBU CodeMeter Runtime before 7.30a. CIROS For future installations, ensure you're using a CIROS installer downloaded from https://ip.festo-didactic.com/ Infoportal/CIROS/EN/Download.html after September 15, 2022. For existing installations, update the WIBU CodeMeter Runtime separately with at least version 7.30a downloaded from the WIBU Systems website. Please refer to the WIBU CodeMeter documentation and website for further details and mitigations on usage of WIBU CodeMeter Runtime before 7.30a. MES PC If your copy of MES4 came preinstalled on a PC shipped before December 2022, you'll need to make sure this PC has at least CodeMeter Runtime 7.30a installed. If necessary, download the update from the WIBU Systems website. Additional to the above: Festo strongly recommends to restrict unprivileged access to machines running Festo software and to minimize and protect network access to connected devices with state of the art techniques and processes. For a secure operation follow the recommendations in the product manuals.

Revision history (3)
  1. Initial publication — 13 December 2022

    Initial revision.

  2. Update A — 11 January 2024

    Adjust link to VDE Advisory

  3. Update B — 1 October 2025

    Adjusted to VDE template. Changed title from "Vulnerable WIBU-SYSTEMS CodeMeter Runtime in multiple Festo products" to "Festo: Vulnerable WIBU-SYSTEMS CodeMeter Runtime in multiple products".

Official source: Festo PSIRT

FSA-202304

Festo: MSE6-C2M/D2M/E2M Incomplete User Documentation of Remote Accessible Functions

Festo — MSE6

Festo PSIRThigh

Published

5 September 2023

Last update

1 October 2025

Linked CVEs

Affected sectors

Risk evaluation

Incomplete user documentation of undocumented, authenticated test mode and further remote accessible functions. The supported features may be covered only partly by the corresponding user documentation. Festo developed the products according to the respective state of the art. As a result, the protocols used no longer fully meet today's security requirements. The products are designed and developed for use in sealed-off (industrial) networks. If the network is not adequately sealed off, unauthorized access to the product can cause damage or malfunctions, particularly Denial of Service (DoS) or loss of integrity.

Mitigation summary

Update of user documentation in next product version.

Revision history (2)
  1. Initial publication — 5 September 2023

    Initial revision.

  2. Update A — 1 October 2025

    Adjusted to VDE template. Changed title from "MSE6-C2M/D2M/E2M Incomplete User Documentation of Remote Accessible Functions" to "Festo: MSE6-C2M/D2M/E2M Incomplete User Documentation of Remote Accessible Functions".

Official source: Festo PSIRT

FSA-202301

Festo: Cross-Site-Scripting (XSS) vulnerability in LX-Appliance

Festo — LX Appliance

Festo PSIRTmiddel

Published

29 August 2023

Last update

1 October 2025

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in the Video.js package could allow a user of LX Appliance, with a high privilege account (i.e., with the "Teacher" role), to craft a malicious course and launch an XSS attack.

Mitigation summary

Contact Festo Didactic services department at services.didactic@festo.com to update your LX Appliance to the latest version.

Revision history (2)
  1. Initial publication — 29 August 2023

    Initial revision.

  2. Update A — 1 October 2025

    Adjusted to VDE template. Changed title from "Video.js Cross-Site-Scripting (XSS) vulnerability in LX Appliance" to "Festo: Cross-Site-Scripting (XSS) vulnerability in LX-Appliance".

Official source: Festo PSIRT

FSA-202303

Festo: Vulnerable Siemens TIA-Portal in multiple Festo Didactic products

Festo — MES-PC

Festo PSIRThigh

Published

17 October 2023

Last update

1 October 2025

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability was reported in Siemens TIA Portal. TIA Portal is part of the installation packages of several Festo Didactic products. TP 260 before June 2023 and MES PC based on DELL XE3 contain a vulnerable versions of TIA Portal V15 to V18. Affected products of TIA Portal contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system.

Mitigation summary

Update TIA-Portal. Please refer to Siemens SSA-116924 for more details.

Revision history (2)
  1. Initial publication — 17 October 2023

    Initial revision.

  2. Update A — 1 October 2025

    Adjusted to VDE template. Changed title from "Vulnerable Siemens TIA-Portal in several Festo Didactic Products" to "Festo: Vulnerable Siemens TIA-Portal in multiple Festo Didactic products".

Official source: Festo PSIRT

VDE-2025-087

WAGO: Vulnerabilities in Device Sphere and Solution Builder

WAGO — Device Sphere

WAGO PSIRTcritical

Published

24 September 2025

Last update

24 September 2025

Affected sectors

Risk evaluation

Due to a missing authentication check, the WAGO Solution Builder and the WAGO Device Sphere are vulnerable to a potential information exposure.

Mitigation summary

Please upgrade to the specified version or a later one of the WAGO Device Sphere or the WAGO Solution Builder.

Revision history (1)
  1. Initial publication — 24 September 2025

    Initial Release.

Official source: WAGO PSIRT

VDE-2018-013

WAGO: 750-8xx Controller Denial of Service

WAGO — PFC100

WAGO PSIRThigh

Published

17 August 2018

Last update

22 September 2025

Linked CVEs

Affected sectors

Risk evaluation

The 750-8xx controller are susceptible to a Denial-of-Service attack due to a flood of network packets. Please consult the original paper for details (link at the bottom of this advisory).

Mitigation summary

We recommend to operate the devices in closed networks or protect with a firewall against unauthorized access. Another, recommended mitigation is to limit the network traffic via the switch rate limit feature according to your application needs. The switch rate limit can be configured e.g. via Web based Management to minimize the effect of high network load: 750-8xx: Ethernet > "Misc. Configuration" > "internal Port" > "Output Limit Rate" 750-8xxx: Network > Ethernet > 'Switch Configuration' > 'Rate Limit' Please also consult the product manuals as this is a known problem for some devices: 750-880 Go to https://www.wago.com/de/sps/controller-ethernet/p/750-880 external link Select "Downloads" In section "Dokumentation" choose "ETHERNET Programmierbarer Feldbuscontroller 10 / 100 Mbit/s; digitale und analoge Signale V 2.3.0, 03.08.2016" and select your language for the manual. See section 9.3: Functional Restrictions and Limits 750-889 Go to https://www.wago.com/de/sps/controller-ethernet/p/750-889 external link Select "Downloads" In section "Dokumentation" choose "Controller KNX IP KNX IP Controller V 1.0.2, 04.10.2016" and select your language for the manual. See section 10.4: Functional Restrictions and Limits 750-831 Go to https://www.wago.com/de/sps/controller-ethernet/p/750-831 external link Select "Downloads" In section "Dokumentation" choose "BACnet/IP Programmierbarer Feldbuscontroller 10/100 Mbit/s; digitale und analoge Signale V 1.2.1, 20.02.2017" and select your language for the manual. See section 9.5: Functional Restrictions and Limits

Revision history (4)
  1. Initial publication — 17 August 2018

    Initial revision.

  2. Update A — 16 January 2025

    Update: add CVE

  3. Update B — 22 May 2025

    Fix: version space, added distribution, quotation mark

  4. Update C — 22 September 2025

    Fix in CVE Number

Official source: WAGO PSIRT

VDE-2025-085

Welotec: Path Traversal in SmartEMS Upload Handling

Welotec — SmartEMS

Welotec PSIRThigh

Published

10 September 2025

Last update

22 September 2025

Linked CVEs

Affected sectors

Risk evaluation

A path traversal flaw in the SmartEMS upload handling allows authenticated users to direct upload data outside of the intended directory via the 'Upload-Key' header. In deployments where writable, code-interpreted paths are reachable, this may lead to remote code execution.

Mitigation summary

Restrict access to the SmartEMS Web UI to trusted admin networks/VPN. Enforce strong credentials and rotate or revoke active tokens/sessions.

Revision history (2)
  1. Initial publication — 10 September 2025

    Initial revision.

  2. Update A — 22 September 2025

    Changes impact note categorie from details to description

Official source: Welotec PSIRT

VDE-2025-083

WAGO: Vulnerability in hardware switch circuit

WAGO — Edge Controller

WAGO PSIRTmiddel

Published

15 September 2025

Last update

15 September 2025

Linked CVEs

Affected sectors

Risk evaluation

The vulnerability in the Ethernet switch circuit is caused by a PullUp resistor at the reset input, leading to premature activation and undefined operation. Switching to a PullDown resistor keeps the switch in reset. This issue affects the CC100, the Touch Panels 600 and the Edge Controller.

Mitigation summary

To address this vulnerability, it is recommended to utilize a newer hardware revision equipped with Firmware 04.08.05 (FW30). This firmware version is designed to resolve the issue by properly managing the switch activation and configuration process on the revised hardware. It is important to note that older firmware versions will not resolve the problem on the new hardware revision, and therefore upgrading both the hardware and firmware is necessary for an effective remediation.

Revision history (1)
  1. Initial publication — 15 September 2025

    Initial revision.

Official source: WAGO PSIRT

VDE-2025-080

WAGO: Multiple Vulnerabilities in I/O-Check Service

WAGO — CC100

WAGO PSIRTcritical

Published

9 September 2025

Last update

9 September 2025

Linked CVEs

Affected sectors

Risk evaluation

A missing authentication vulnerability exists in the iocheckd service "I/O-Check" functionality. A single packet can cause a denial of service and weaken credentials resulting in the default documented credentials being applied to the device. An attacker can send an unauthenticated packet to trigger this vulnerability.

Mitigation summary

The I/O-Check service protocol is only needed during installation and commissioning, not during normal operations. It is highly recommended to disable the IP-port 6626 after commissioning.

Revision history (1)
  1. Initial publication — 9 September 2025

    Initial revision.

Official source: WAGO PSIRT

VDE-2025-075

Beckhoff: Deserialization of untrusted data by TwinCAT 3 Engineering

Beckhoff — TE1000 | TwinCAT 3 Enineering

Beckhoff PSIRThigh

Published

9 September 2025

Last update

9 September 2025

Linked CVEs

Affected sectors

Risk evaluation

Beckhoff's TwinCAT 3 Engineering software is intented to craft automation projects consisting of a set of files which are stored locally as files underneath an individual folder or in a packed file. The TwinCAT 3 Engineering stores user settings and preferences among the non packed local files which are relevant to continue former work on the project conventienly. TwinCAT 3 Engineering stores such settings in files which are called "Solution User Options (.suo) File". When such settings are manipulated or crafted by an adversary in a specific way then TwinCAT 3 Engineering executes arbitrary commands as determined by these settings when the user uses TwinCAT 3 Engineering to open the project. These arbitrary commands are executed in the user context. Please note that solution user option files should not be checked in to source code control. This is also a best practice when working with source code projects and solutions. For example, see https://learn.microsoft.com/en-us/visualstudio/extensibility/internals/solution-user-options-dot-suo-file and https://infosys.beckhoff.com/content/1033/tc3_sourcecontrol/14604066827.html. The vulnerability is similar to older vulnerabilities that were addressed in the CODESYS Development System V3 product from CODESYS GmbH with CVE-2021-21864, CVE-2021-21865, CVE-2021-21866, CVE-2021-21867, CVE-2021-21868, CVE-2021-21869, and the associated Advisory 2021-13 from CODESYS GmbH.

Mitigation summary

Please update to a recent version of the affected product and uninstall older versions of TwinCAT 3 Engineering. Make sure that older versions of TwinCAT 3 Engineering do not occur as "Remote Manager" versions, see https://infosys.beckhoff.com/content/1033/tc3_remote_manager/index.html?id=1584127271344589360. Remove the "pinning" from your projects to older versions of TwinCAT 3 Engineering, if present, see https://infosys.beckhoff.com/content/1033/tc3_remote_manager/3154642571.html.

Revision history (1)
  1. Initial publication — 9 September 2025

    initial revision

Official source: Beckhoff PSIRT

VDE-2025-048

WAGO: Escalation of Privileges in Coupler Firmware

WAGO — 750 Fieldbus Coupler

WAGO PSIRThigh

Published

8 September 2025

Last update

8 September 2025

Linked CVEs

Affected sectors

Risk evaluation

A design flaw in the file system management exposes internal system partitions - intended to be hidden - during brief moments when they are mounted by the firmware. These partitions contain sensitive data such as firmware and certificates. Although access to the file system is mediated by a Nucleus layer that supports permission control, these permissions are currently not enforced. As a result, services like FTP/SFTP may inadvertently gain access to critical internal resources, increasing the risk of unauthorized access or data leakage.

Mitigation summary

Update to Firmware version 13.

Revision history (1)
  1. Initial publication — 8 September 2025

    initial version

Official source: WAGO PSIRT

VDE-2025-082

WAGO: Critical sudo Vulnerability in Multiple Products

WAGO — CC100

WAGO PSIRThigh

Published

8 September 2025

Last update

8 September 2025

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in sudo allows a low privileged attacker to execute commands with root rights.

Mitigation summary

Update to Firmware version 04.08.01 (FW30) or higher.

Revision history (1)
  1. Initial publication — 8 September 2025

    Initial revision.

Official source: WAGO PSIRT

VDE-2025-061

Bender Charge Controller Vulnerability - Disclosure Of Stored Credentials When Authenticated

Bender — CC612

Bender PSIRThigh

Published

8 September 2025

Last update

8 September 2025

Linked CVEs

Affected sectors

Risk evaluation

Bender is publishing this advisory to inform customers about a security vulnerability in the Charge Controller product families. Bender has analyzed the weakness and determined that the electrical safety of the devices is not affected. Bender considers the weakness to be of high risk and it should be patched immediately.

Mitigation summary

Install software update 5.33.3 or later.

Revision history (1)
  1. Initial publication — 8 September 2025

    initial version

Official source: Bender PSIRT

VDE-2025-084

Bender Charge Controller Vulnerability - Unsecure Communication

Bender — CC612

Bender PSIRThigh

Published

8 September 2025

Last update

8 September 2025

Linked CVEs

Affected sectors

Risk evaluation

Bender is publishing this advisory to inform customers about a security vulnerability in the Charge Controller product families. Bender has analyzed the weakness and determined that the electrical safety of the devices is not affected. Bender considers the weakness to be of high risk and it should be patched immediately.

Mitigation summary

Enable use of HTTPS in the charge controller configuration Web UI settings>system>https

Revision history (1)
  1. Initial publication — 8 September 2025

    initial version

Official source: Bender PSIRT

Advisory2025-07_VDE-2025-051

CODESYS Control V3 - Exposed PKI folder

CODESYS — CODESYS Control RTE (SL)

CODESYS PSIRThigh

Published

4 August 2025

Last update

1 September 2025

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in the CODESYS Control runtime system allows low-privileged remote attackers to access the PKI folder via CODESYS protocol, enabling them to read and write certificates and keys. This exposes sensitive cryptographic data and allows unauthorized certificates to be trusted. However, all services remain available, only certificate based encryption and signing features are concerned. The issue affects systems using the optional CmpOpenSSL component for cryptographic operations. **Update 1.1.0, 01.09.2025:** Updated remediation category - fixed SL runtimes are now available.

Mitigation summary

Update the following products to version 3.5.21.20. * CODESYS Control RTE (SL) * CODESYS Control RTE (for Beckhoff CX) SL * CODESYS Control Win (SL) * CODESYS HMI (SL) * CODESYS Runtime Toolkit The CODESYS Development System and the products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/. Following our general recommendation that the PKI should only be managed via the dedicated X.509 API or the corresponding online services of the CODESYS Control runtime system, the programmatic direct access via SysFile or SysDir operations or online access via the CODESYS file transfer services is denied after an update to a fixed product version. For compatibility reasons, the old behavior can be restored for applications that use these accesses via the following setting: [CmpOpenSSL] EnforceBlacklistOnPKIDir=0 However, we strongly recommend keeping the new default.

Revision history (2)
  1. Initial publication — 4 August 2025

    Initial revision.

  2. Update A — 1 September 2025

    Updated remediation category - fixed SL runtimes are now available.

Official source: CODESYS PSIRT

VDE-2025-078

TRUMPF: Remote support uses an outdated encryption algorithm

TRUMPF — Telepresence Box

TRUMPF PSIRThigh

Published

25 August 2025

Last update

29 August 2025

Linked CVEs

Affected sectors

Risk evaluation

The TRUMPF remote support infrastructure selects an outdated encryption algorithm when setting up communication channels for machines. This cannot be prevented for old machines. For most machines it is possible to change the encryption settings.

Mitigation summary

Since August 8st, 2025, an automated configuration update is available for TRUMPF machines with a Telepresence Box 7.0.0 and newer. It will automatically be applied when activating a remote session from the machine. It is not necessary for a TRUMPF technician to join the session.

Revision history (2)
  1. Initial publication — 25 August 2025

    Initial version

  2. Update A — 29 August 2025

    Changed affected Product from 7.0.0<10.0.0 to 7.0.0<8.0.0

Official source: TRUMPF PSIRT

VDE-2024-038

Pepperl+Fuchs: Anonymous FTP server and Telnet access allows information disclosure and manipulation

Pepperl+Fuchs — OIT1500-F113-B12-CB

Pepperl+Fuchs PSIRTcritical

Published

10 July 2024

Last update

27 August 2025

Affected sectors

Risk evaluation

Critical vulnerabilities has been discovered in the product, mainly caused by ananonymous FTP server and Telnet access.The impact of the vulnerabilities on the affected device may result in Information disclosure Denial of service Device manipulation

Mitigation summary

An external protective measure is required. Minimize network exposure for affected products and ensure that they are not accessible via the Internet. Isolate affected products from the corporate network. If remote access is required, use secure methods such as virtual private networks (VPNs).

Revision history (2)
  1. Initial publication — 10 July 2024

    Initial revision.

  2. Update A — 27 August 2025

    Update: CWE from CVE-2024-6421, Revision History

Official source: Pepperl+Fuchs PSIRT

VDE-2025-011

PEPPERL+FUCHS: Profinet Gateway LB8122A.1.EL – Device is affected by XSS vulnerability and information disclosure

Pepperl+Fuchs — Profinet Gateway LB8122A.1.EL

Pepperl+Fuchs PSIRThigh

Published

26 May 2025

Last update

27 August 2025

Affected sectors

Risk evaluation

A stored cross-site scripting vulnerability has been discovered in the profinet gateway LB8122A.1.EL. An attacker can write an HTML tag with up to 32 characters in the message field of a HART transmitter. The HTML tag is interpreted as HTML when the HART information is displayed in a webbrowser. If the HTML tag contains a link to a manipulated page, a user can be tricked into accessing this page. Furthermore, an attacker can access information about running processes via the SNMP protocol. Sending such SNMP read commands can also trigger a reboot.

Mitigation summary

Please install the updated firmware V1.3.13.

Revision history (2)
  1. Initial publication — 5 June 2025

    Initial revision.

  2. Update A — 27 August 2025

    Update: CWE from CVE-2025-41654, Revision History

Official source: Pepperl+Fuchs PSIRT

VDE-2025-044

Weidmueller: Industrial ethernet switches are affected by multiple vulnerabilities

Weidmüller — IE-SW

Weidmüller PSIRTcritical

Published

27 May 2025

Last update

27 August 2025

Affected sectors

Risk evaluation

Weidmueller industrial ethernet switches are affected by multiple vulnerabilities. Weidmueller has released new firmwares of the affected products to fix the vulnerabilities.

Mitigation summary

Update to version V3.6.32

Revision history (2)
  1. Initial publication — 27 May 2025

    Initial version

  2. Update A — 27 August 2025

    Update: CWE from CVE-2025-41652, Revision History

Official source: Weidmüller PSIRT

VDE-2024-056

MB connect line: Multiple Vulnerabilities in mbNET.mini Product

MB connect line — mbNET.mini

MB connect line PSIRTcritical

Published

15 October 2024

Last update

27 August 2025

Affected sectors

Risk evaluation

Multiple vulnerabilities have been discovered in MB connect line mbNET.mini product allowing for RCE or unauthorized file access.

Mitigation summary

Update mbNET.mini to the version 2.3.1

Revision history (4)
  1. Initial publication — 15 October 2024

    Initial revision.

  2. Update A — 6 November 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 14 May 2025

    Fix: version space

  4. Update C — 27 August 2025

    Update: CWE from CVE-2024-45271, Revision History

Official source: MB connect line PSIRT

VDE-2024-010

Vulnerabilities in mbCONNECT24/mymbCONNECT24

MB connect line — mbCONNECT24

MB connect line PSIRTcritical

Published

18 March 2025

Last update

27 August 2025

Affected sectors

Risk evaluation

The data24 service that is bundled with every installation of mbCONNECT24/mymbCONNECT24 has two serious flaws in core components. These combined can lead to a complete loss of confidentiality, integrity and availability.

Mitigation summary

Update to latest version: 2.16.2 CVE-2024-23943: This fix does not apply to mbNET/mbNET.rokey devices with firmware 8.0.0 - 8.1.3. If you are using a device with this firmware, please update it to >= 8.2.0.

Revision history (4)
  1. Initial publication — 18 March 2025

    Initial revision.

  2. Update A — 31 March 2025

    Update: Fixed Document reference CSAF

  3. Update B — 10 April 2025

    Update: Fixed document reference URL

  4. Update C — 14 May 2025

    Fix: added distribution

Official source: MB connect line PSIRT

VDE-2024-066

Helmholz: Multiple Vulnerabilities in Helmholz REX100 Product

Helmholz — REX100

Helmholz PSIRTcritical

Published

15 October 2024

Last update

27 August 2025

Affected sectors

Risk evaluation

Multiple vulnerabilities have been discovered in REX100 allowing for RCE or unauthorized file access.

Mitigation summary

Update REX100 to the version 2.3.1

Revision history (4)
  1. Initial publication — 15 October 2024

    Initial revision.

  2. Update A — 6 November 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 12 March 2025

    removed spaces around version operators

  4. Update C — 27 August 2025

    Update: CWE from CVE-2024-45271, Revision History

Official source: Helmholz PSIRT

FSA-202101

Festo: Multiple vulnerabilities in Ethernet/IP Stack of SBRD-Q/SBOC-Q/SBOI-Q

Festo — SBOC-Q

Festo PSIRThigh

Published

22 September 2021

Last update

26 August 2025

Affected sectors

Risk evaluation

The affected product families are cameras SBOC/SBOI and the Controller SBRD. The vulnerabilities are located within the Ethernet IP Stack from EIPStackGroup OpENer Ethernet/IP.

Mitigation summary

- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. - Deactivate EtherNet/IP in device settings if not used

Revision history (3)
  1. Initial publication — 28 September 2021

    Initial revision.

  2. Update A — 11 January 2024

    Adjust link to VDE Advisory

  3. Update B — 26 August 2025

    Adjusted to VDE template. Changed document title from 'Vulnerability in Ethernet/IP Stack of SBRD-Q/SBOC-Q/SBOI-Q' to 'Festo: Multiple vulnerabilities in Ethernet/IP Stack of SBRD-Q/SBOC-Q/SBOI-Q'. Updated legal disclaimer to add references to special provisions.". Updated vulnerability notes and mitigation information. Updated legal disclaimer to add references to special provisions.

Official source: Festo PSIRT

VDE-2025-076

Welotec: Hard-coded JWT secret in egOS WebGUI

Welotec — EG400Mk2

Welotec PSIRTcritical

Published

26 August 2025

Last update

26 August 2025

Linked CVEs

Affected sectors

Risk evaluation

A hard-coded JWT secret in the egOS WebGUI backend is readable to the default user, allowing attackers to forge valid tokens and access protected API endpoints.

Mitigation summary

Temporarily disable the WebGUI or restrict network access to the WebGUI to trusted admin stations.

Revision history (1)
  1. Initial publication — 26 August 2025

    initial version

Official source: Welotec PSIRT