Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X and recommends to update to the latest version.
Mitigation summary
Update to V2604 or later version
Revision history (2)
Initial publication — 14 July 2026
Publication Date
Update A — 21 July 2026
Initial CISA Republication of Siemens ProductCERT SSA-096828 advisory
VDE-2026-044
MB connect line: Multiple SQLi vulnerabilities in mbCONNECT24/mymbCONNECT24
Published
27 May 2026
Last update
20 July 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities have been discovered in MB connect line mbCONNECT24/mymbCONNECT24.
Mitigation summary
Update the mbCONNECT24/mymbCONNECT24 instance to version 2.20.1.
Revision history (2)
Initial publication — 27 May 2026
Initial revision.
Update A — 20 July 2026
Added missing CVE-2026-14448, Revised Summary and Impact accordingly, starting version
VDE-2026-058
Helmholz: Multiple SQLi vulnerabilities in myREX24V2/myREX24V2.virtual
Published
21 May 2026
Last update
20 July 2026
Linked CVEs
Affected sectors
Risk evaluation
Helmholz: Multiple SQLi vulnerabilities in myREX24V2/myREX24V2.virtual
Mitigation summary
Update the myREX24V2/myREX24V2.virtual instance to version 2.20.1.
Revision history (2)
Initial publication — 21 May 2026
Initial revision.
Update A — 20 July 2026
Added missing CVE-2026-14448, Revised Summary and Impact accordingly, starting version
9AKK108472A9270
ABB/EL/ELSB/Building Automation File integrity can be bypassed in KNX Update Tool for classic KNX products
Risk evaluation
ABB has been contacted by a researcher who identified a vulnerability in one of its products. ABB has been contacted by a researcher who identified a vulnerability in one of its products. The vulnerability report has been shared in responsible disclosure. An attacker who successfully exploited this vulnerability could cause the product to become unusable. ABB confirms the vulnerability but at the same time acknowledges that the issue affects exclusively classic KNX devices that are not supporting the latest KNX Secure standard. Due to a lack of security in legacy KNX devices, the issue cannot be resolved via a software change. In order to actively exploit this vulnerability, an attacker requires physical access to the bus, the affected device is connected to. ABB has no plans of corrective measures.
Mitigation summary
Due to the nature of the classic KNX protocol stack and security concept, there are no options to resolve the vulnerability with a software update on a technical level. ABB recommends to follow general security recommendations listed in the security guideline (see References and General security recommendations). In addition, it shall be avoided to control sensitive functionality by legacy KNX devices such as, but not limited to, access control to e.g. hotel rooms or other protected areas. Note: Legacy KNX standards were never designed to meet state of the art security standards like introduced with KNX Data Secure published in 2017.
Revision history (1)
Initial publication — 17 July 2026
Initial version
Risk evaluation
A vulnerability was discovered in several Endress+Hauser products that can be accessed via ethernet.
Mitigation summary
Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.
Revision history (1)
Initial publication — 16 July 2026
Initial version
VDE-2026-045
Endress+Hauser: Multiple products affected by SopasET interface vulnerability
Risk evaluation
A vulnerability was discovered in several Endress+Hauser products that can be accessed via ethernet.
Mitigation summary
Restrict device access to trusted and authorized entities only. Apply the general security measures during product operation to mitigate the identified security risk. Refer to the ICS‑CERT Recommended Practices for Industrial Security for additional guidance.
Revision history (1)
Initial publication — 16 July 2026
Initial version
ICSA-26-197-09
Rockwell Automation FactoryTalk DataMosaix
Risk evaluation
Successful exploitation of this vulnerability could allow an authenticated attacker to inject malicious scripts on the server.
Mitigation summary
Rockwell Automation recommends users to upgrade to the following: DataMosaix Private Cloud versions 8.03 or later.
Revision history (1)
Initial publication — 16 July 2026
Initial Republication of Rockwell Automation Security Advisory SD1787
Risk evaluation
Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected product.
Mitigation summary
Rockwell Automation recommends users to upgrade to the following: Flex 5000 Adapter version 6.012.
Revision history (1)
Initial publication — 16 July 2026
Initial Republication of Rockwell Automation Security Advisory SD1789
Risk evaluation
Successful exploitation of this vulnerability allows an authenticated attacker to escalate privileges and access spaces outside their assigned partition, within the same Salto ProAccess Space installation or system. Exploitation requires valid authenticated operator credentials and the partition feature to be enabled; installations without partitioning are not affected.
Mitigation summary
Users of SALTO ProAccess using the tenancy feature should upgrade to version 6.13.
Revision history (1)
Initial publication — 16 July 2026
Initial Publication
Risk evaluation
Multiple Murrelektronik network-enabled devices respond to SNMPv2c 'GETBULK' requests with disproportionately large response packets when the requesting party specifies a large max-repetitions value. This response amplification allows the affected devices to be misused as reflectors in distributed denial-of-service (DDoS) attacks against arbitrary third-party victims on the internet.
Mitigation summary
A firmware update that addresses the SNMP GETBULK response amplification behaviour is planned for release in early 2027 for the Murrelektronik MVK Pro and Impact67 Pro product lines. Until the fix becomes available, customers should apply the mitigations described above.
Revision history (1)
Initial publication — 14 July 2026
initial release
Risk evaluation
Several Murrelektronik devices using Profinet are shipped with the default SNMP community names ('public' for read access and 'private' for write access). If these community strings remain unchanged in the field, an unauthenticated attacker with network access to the device can read its configuration and, depending on the writable OIDs, modify device settings.
Mitigation summary
A firmware update addressing the vulnerability is planned for early 2027 for the Impact67 Pro (article numbers 54620, 54630) and MVK Pro (article numbers 54600, 54610) product variants.
Revision history (1)
Initial publication — 14 July 2026
initial release
SEVD-2025-014-06
RemoteConnect and SCADAPack™ x70 Utilities
Schneider Electric — RemoteConnect and SCADAPack™ x70 Utilities - RemoteConnect
Risk evaluation
Schneider Electric is aware of a vulnerability in its RemoteConnect and SCADAPack™ x70 Utilities software product. The RemoteConnect and SCADAPack™ x70 Utilities https://www.se.com/ww/en/product-category/6000-telemetry-and-remote-scada-systems/ product is a configuration software providing a user interface that allows users to configure and manage communications and operations for SCADAPack™ x70 devices. Failure to apply the Mitigations provided below may risk deserialization of untrusted data, which could result in loss of confidentiality, integrity and potential remote code execution on the compromised workstation.
Mitigation summary
Version R3.4.2 RemoteConnect configuration software includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/
Revision history (3)
Initial publication — 14 January 2025
Original Release
Update A — 13 January 2026
The affected versions for the RemoteConnect and Security Administrator has been identified, and a remediation is now available for the RemoteConnect configuration software included in the RemoteConnect and SCADAPack™ x70 Utilities product bundle.
Update B — 14 July 2026
Remediations are now available for the Security Administrator configuration software included in the RemoteConnect and SCADAPack™ x70 Utilities product bundle.
Risk evaluation
Schneider Electric is aware of a vulnerability in its IGSS Definition module for the IGSS (Interactive Graphical SCADA System) product. The [IGSS](https://igss.schneider-electric.com/) product is a state-of-the-art SCADA system used for monitoring and controlling industrial processes. The IGSS Definition module is a design-time component used by system integrators to create mimic diagrams for plant personnel, enabling them to monitor and control the SCADA system. Failure to apply the remediation provided below may risk loss of data or arbitrary code execution, which could result in the loss of control of the system.
Mitigation summary
Version 18.0.0.26125 of the IGSS Definition module includes a fix for this vulnerability and is available for download through IGSS Master > Update IGSS Software or here: https://igss.schneider-electric.com/igss/igssupdates/v180/IGSSUPDATE.ZIP
Revision history (1)
Initial publication — 14 July 2026
Original Release
SEVD-2026-195-02
Insufficiently Protected Credentials vulnerability on EcoStruxure™ Cybersecurity Admin Expert
Schneider Electric — EcoStruxure™ Cybersecurity Admin Expert
Risk evaluation
Schneider Electric is aware of a vulnerability in its EcoStruxure™ Cybersecurity Admin Expert product (CAE). The [EcoStruxure™ Cybersecurity Admin Expert](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=63515) product is a configurator for managing cybersecurity in your electrical network’s operational technology (OT). It is an intuitive, software-based tool used for multiple administration purposes. Failure to apply the remediation provided below may risk an authentication bypass and privilege escalation attack, which could result in unauthorized access to application accounts, manipulation of credentials, and potential compromise of managed devices.
Mitigation summary
Version 4.2.1 of EcoStruxure™ Cybersecurity Admin Expert (CAE) includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/63515-ecostruxure-cybersecurity-admin-expert/#software-and-firmware Host computer reboot is required.
Revision history (1)
Initial publication — 14 July 2026
Original Release
Advisory2026-04_VDE-2026-040
CODESYS EtherNetIP - Improper timeout handling
Risk evaluation
CODESYS EtherNet/IP is an add‑on for the CODESYS Development System that provides a fully integrated EtherNet/IP protocol stack along with diagnostic capabilities. A flaw in the EtherNet/IP adapter protocol stack library results in a vulnerability within the generated application code. When an EtherNet/IP adapter is configured, this vulnerable protocol stack is downloaded to and executed by CODESYS Control runtime systems. Under certain non‑standard operating conditions, the EtherNet/IP adapter fails to perform timeout checks on active TCP connections. As a result, once all available TCP connections are in use, expired connections are not released and no new TCP connections can be established. Existing connections remain unaffected and continue to operate normally. This issue affects only CODESYS projects that include an EtherNet/IP adapter configuration.
Mitigation summary
Update the following products to version 4.9.0.0. * CODESYS EtherNetIP To make the fix effective for existing CODESYS projects, you must additionally update the EtherNet/IP adapter in the device tree to the latest version and perform a download of the CODESYS application to the PLC. The CODESYS Development System and the products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/.
Revision history (2)
Initial publication — 23 April 2026
Initial revision.
Update A — 13 July 2026
Corrected semantic version information; added EtherNet/IP adapter update step to remediation instructions.
VDE-2026-031
WAGO: Early-Boot Diagnostic Exposure in WAGO System I/O Field Devices
Risk evaluation
Certain devices in the WAGO System I/O Field series enable an internal diagnostic capability during the initial stages of system startup. This behavior, which is not part of the publicly documented feature set, briefly allows access to system functions before the main operating environment becomes fully active. Under specific conditions, this could permit interactions with system components that are normally protected during regular operation.
Mitigation summary
Update to the listed fixed versions of the affected firmwares: | Fixed Version | Product Name | | ------------- | ------------------------------------ | | 1.2.1.100 | I/O System Field 0765-110x/0100-0000 | | 1.2.7.100 | I/O System Field 0765-120x/0100-0000 | | 1.2.7.103 | I/O System Field 0765-150x/0100-0000 | | 1.2.1.102 | I/O System Field 0765-2101/0100-0000 | | 1.2.5.101 | I/O System Field 0765-2102/0100-0000 | | 1.2.1.100 | I/O System Field 0765-410x/0100-0000 | | 1.2.7.100 | I/O System Field 0765-420x/0100-0000 | | 1.2.7.103 | I/O System Field 0765-450x/0100-0000 |
Revision history (1)
Initial publication — 13 July 2026
Release version.
SCA-2026-0008
Vulnerability Affecting SICK Sentio Creator Extension “Software Deployment Manager”
Risk evaluation
The pre-installed Software Deployment Manager extension in SICK Sentio Creator is affected by CVE-2026-33151. The Software Deployment Manager extension is maintained and updated independently from SICK Sentio Creator and therefore SICK recommends applying the defined remediations for the vulnerability.
Mitigation summary
Users are strongly recommended to upgrade the Software Deployment Manager extension for Sentio Creator to version 0.14.0.
Revision history (1)
Initial publication — 10 July 2026
Initial version
VDE-2026-071
JUMO: Allegro RomPager webserver vulnerability in JUMO mTRONT, DICON touch, AQUIS touch devices
Published
23 June 2026
Last update
8 July 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple products from JUMO are affected by webserver vulnerability "CVE-2013-6786, CVE-2014-9222, CVE-2014-9223. This vulnerability leads to DOS of the device by using a misfortune cookie and reflected XSS attacks.
Mitigation summary
Update affected devices to: Version 248.05.02 for JUMO mTRON T Central Processing Unit Version 249.05.03 for JUMO mTRON T Multifunction panel 840 Version 266.04.07 for JUMO DICON touch Version 304.09.04 for JUMO AQUIS touch
Revision history (2)
Initial publication — 23 June 2026
initial release
Update A — 8 July 2026
Updated the relationship identifier and adjusted the starting versions in the product tree version ranges.
Risk evaluation
The vulnerability enables unauthorized access to the Reboot OS function within the Remote Transport Service, allowing an attacker to trigger a system reboot without the required authentication. This functionality initiates a system reboot on the target machine. However, remote exploitation of this vulnerability is not feasible unless the attacker has already gained access to the network where the affected ABB Ability™ zenon system is deployed. At the time of writing, there is no evidence that this vulnerability is being actively exploited in the wild.
Mitigation summary
- Restrict network access to systems with the ABB zenon Software Platform installed. - Ensure that access to a system is restricted by implementing access controls to minimize the risk of unauthorized access. - Assess the necessity of the ABB zenon Remote Transport functionality. - Ensure that if the Remote Transport functionality is not used, the zensyssrv.exe (ABB zenon System Service) is stopped or terminated. The zensyssrv.exe can also be stopped or terminated after authorized use to prevent this vulnerability.
Revision history (2)
Initial publication — 12 August 2025
Initial version.
Update A — 6 July 2026
Updated the document with the vulnerability fix information
Published
6 July 2026
Last update
6 July 2026
Affected sectors
Risk evaluation
An update is available that resolves several vulnerabilities and updates one or more 3rd party components in the product versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could impact the availability of the product, spoof identities or elevate privileges.
Mitigation summary
The problem is corrected in the following product versions: - APROL >= R 4.4-01P5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revision history (1)
Initial publication — 6 July 2026
Initial version.
VDE-2025-067
Wiesemann & Theis: Motherbox 3 allows unauthenticated read-only DB access
Risk evaluation
Motherbox 3 with firmware 1.44 to 1.48 allows an unauthenticated remote attacker read-only access to the internal DB with measurement values from other W&T sensor devices.
Mitigation summary
Access to the database should be limited to trustworthy networks or peers.
Revision history (3)
Initial publication — 10 August 2025
Initial revision
Update A — 25 August 2025
Changed CVE Score from C:L to C:H and changed in the CVE Description the word "grants" to "get"
Update B — 3 July 2026
Fixed Vendor Variable in Product tree
Risk evaluation
ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete control of the system
Mitigation summary
The problem is corrected in the following product versions: - Edgenius 3.2.4.1 ABB recommends that customers apply the update at earliest convenience.
Revision history (1)
Initial publication — 25 June 2026
Initial version.
VDE-2026-070
Helmholz: Authenticated unintended access to critical program parameters in myREX24V2/myREX24V2.virtual
Risk evaluation
There is a vulnerability in myREX24V2/myREX24V2.virtual that allows an authenticated remote attacker to access a hidden configuration method, that should not be accessible by any user, to modify critical program parameters.
Mitigation summary
Update the myREX24V2/myREX24V2.virtual instance to version 2.20.2.
Revision history (2)
Initial publication — 23 June 2026
Initial revision.
Update A — 23 June 2026
The alias has been corrected
VDE-2026-068
MB connect line: Authenticated unintended access to critical program parameters in mbCONNECT24/mymbCONNECT24
Risk evaluation
There is a vulnerability in mbCONNECT24/mymbCONNECT24 that allows an authenticated remote attacker to access a hidden configuration method, that should not be accessible by any user, to modify critical program parameters.
Mitigation summary
Update the mbCONNECT24/mymbCONNECT24 instance to version 2.20.2.
Revision history (1)
Initial publication — 23 June 2026
Initial revision.
Risk evaluation
ABB became aware of vulnerability in the products versions listed as affected in the advisory, where an incorrect version of Online Builder (ONB) was included in the media. An update is available that resolves the vulnerability, see details in Recommended immediate actions.
Mitigation summary
ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
Revision history (1)
Initial publication — 23 June 2026
Initial version.